2013-1035 Gorman Addition.pdf
City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: October 11, 2013
TO: John Tregidga
Email: jt_capa@live.com
FROM: Leif Bjorback, Building Official
RE: Plan Check: 2013-1035
Project: Gorman Addition
th
Project Address: 8419 198 St SW
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can
be found on the plans, and submit revised plans/documents to a permit coordinator in the
Development Services Department. Thank you.
1.Show the floor joist size and spacing on the foundation plan.
2.The note on sheet A-3 at the Great Room bay window states to Demo window & replace
with glass door. Please show the glass door on sheet A-2 floor plan and show the adjacent
windows as safety glazed.
3.Page 1 of the structural calculations shows a 3.5 foot section of S1-6 (see page A-2) adjacent
to the sliding glass door, but is not shown on the floor plan. Please revise the floor plan to
show this section of shearwall or provide revised engineering to just a reduced shearwall
design.
4.Please provide gravity calculations for the following beams:
a.4x6 roof beam outside of the sliding glass door.
b.4x8 deck girder supporting the 4x6 beam in a) above.
c.Flush 5-1/2 x 15 glulam supporting the Great Room ceiling.