Loading...
2013-1035 Gorman Addition.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 11, 2013 TO: John Tregidga Email: jt_capa@live.com FROM: Leif Bjorback, Building Official RE: Plan Check: 2013-1035 Project: Gorman Addition th Project Address: 8419 198 St SW During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.Show the floor joist size and spacing on the foundation plan. 2.The note on sheet A-3 at the Great Room bay window states to “Demo window & replace with glass door.” Please show the glass door on sheet A-2 floor plan and show the adjacent windows as safety glazed. 3.Page 1 of the structural calculations shows a 3.5 foot section of S1-6 (see page A-2) adjacent to the sliding glass door, but is not shown on the floor plan. Please revise the floor plan to show this section of shearwall or provide revised engineering to just a reduced shearwall design. 4.Please provide gravity calculations for the following beams: a.4x6 roof beam outside of the sliding glass door. b.4x8 deck girder supporting the 4x6 beam in a) above. c.Flush 5-1/2 x 15 glulam supporting the Great Room ceiling.