20140602143620197.pdf. ... ......... . To: Chuck Miller Plans Examiner -�e: Correction Notice (5/22/2014) Project Address: 1049 8 th Ave S Project #: BLD2014-0311 Thank you for your time and consideration in this matter. Here is the information, corrections or clarifications that you requested. 66. A note has been added to S3 for the footing to be constructed per detail FWS. 67.1 reviewed the west -most header in the south garage wall. It has only uniform load on it. Beam 1-10 is 2-2x8 on the north garage and has the same load and a larger span (and the loading appears larger than needed). 2-2x8 header is okay, no change to the plan required. 68.That strap is not located on the end so that it aligns with the shearwall end below. The callout has been clarified to read as such. The reduced moment arm was checked and the strap called out is sufficient. 69. Same response as #68. 70. Same response as #68. 71. Same response as #68. 72. Detail FTO has been added so S5. 73. Detail ISR has been added to S5. 74.The header over the east Master Bed window has been changed to a 4x8. Calculation 2-11 is attached. For clarification, each window header over the west wall has been called out as 2-2x8 so that a single span is not made by the contractor. 75.The reaction from the girder truss has been added to beam 2-1 (calculation attached). 4x12 still works, no change to the plan needed. 76. The HANGER PER TRUSS MFG note has been moved to where G.T. 2-8 connects to the 4x12 beam. If you have any questions, require additional information, or believe we have misinterpreted your requests, please call us at 425-778-1023, and we'd be happy to discuss them. Attached: beam calculation 2-1 and 2-11; reduced plans S3 & S5 with comment numbers 6628 212th Street SVV, Suite 205 - Lynnwood, WA 98036 - Ph: 425-778-3.023 - Fax: 206-260-7490 ®®d �111 ---- — File= klServeftsslJobs\s14\Sl6B2B-1\WO1405-11S14030-1.EC6� ENERCALC, INC. 1983-2014, Buiki:6.14.1.26, Ver.6.14.1.26 Description : 2-1 rev140529 Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties _ Analysis Method: Allowable Stress Design Fb - Tension 900.0 psi Load Combination ASCE 7-10 Fb - Compr 900.0 psi Fc - Prll 1,350.0 psi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.2 Fv 180.0 psi Ft 575.0 psi Beam Bracing ; Beam is Fully Braced against lateral -torsion buckling D(0.86) S(1.43) 4x12 Span = 8.250 ft Applied Loads Beam self weight calculated and added to loads Uniform Load: D = 0.0150, S = 0.0250 ksf, Tributary Width =18.0 ft, (ROOF) Point Load: D = 0.860, S =1.430 k () 0.6250 fl DESIGN SUMMARY E : Modulus of Elasticity Ebend- xx 1,600.0 ksi Eminbend - xx 580.0 ksi Maximum Bending Stress Ratio = : 1 Maximum Shear Stress Ratio Section used for this span 4x12 Section used for this span fb : Actual _ 1,127.51 psi N : Actual FB : Allowable = 1,138.50 psi Fv : Allowable Load Combination +D+S+H Load Combination Location of maximum on span = 3.884ft Location of maximum on span Span # where maximum occurs - Span # 1 Span # where maximum occurs Maximum Deflection Max Downward L+Lr+S Deflection 0.081 in Ratio = Max Upward L+Lr+S Deflection 0,000 in Ratio = <360 Max Downward Total Deflection 0.131 in Ratio = Max Upward Total Deflection 0.000 in Ratio = <240 Overall Maximum Deflections - Unfactored Loads Density 32.210pcf 4xl2 195.16 psi 207.00 psi +D+S+H = 0.000 ft Span # 1 Load Combination Span Max. ° " Dell Location in Span Load Combination Max. "+" Dell Location in Span D+S 1 0.1309 4.065 0.0000 0.000 Vertical Reactions - Unfactored Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MINimum 1.945 1.215 D Only 1.945 1.215 S Only 3.178 1.965 D+S 5.123 3.180 — — File =kkServerlsssUobs1s141S16B2B-1\W01405-11S14030-1.EC6 ®®d ENERCALC, INC. 1983-2014, BuiW:6.14.1.26, Ver.6.14.1.26 _ Description : 2-11 add140529 CODE REFERENCES Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set: ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Fb - Tension 900 psi _ E : Modulus of Elasticity Load Combination ASCE 7-10 Fb - Compr 900 psi Ebend- xx 1600 ksi Fe - Prll 1350 psi Eminbend - xx 580 ksi Wood Species ; Douglas Fir - Larch Fc - Perp 625 psi Wood Grade : No.2 Fv 180 psi Ft 575 psi Density 32.21 pcf Beam Bracing : Beam is Fully Braced against lateral -torsion buckling D 0.15 0.25 V 4x8 Span =8.0ft Applied Loads Beam self weight calculated and added to loads Uniform Load: D = 0,0150, S = 0.0250 ksf, Tributary Width =10.0 ft, (ROOF) DESIGN SUMMARY Maximum Bending Stress Ratio = : 1 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span fb : Actual = 1,270.16 psi fv : Actual FB : Allowable = 1,345.50psi Fv : Allowable Load Combination +D+S+H Load Combination Location of maximum on span = 4.000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward L+Lr+S Deflection 0.130 in Ratio = Max Upward L+Lr+S Deflection 0.000 in Ratio = <360 Max Downward Total Deflection 0.211 in Ratio = Max Upward Total Deflection 0.000 in Ratio = <240 Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. ° " Defi Location in Span Load Combination 4x8 95.92 psi 207.00 psi +D+S+H 0.000 ft Span # 1 Max. "+" Dell Location in Span D+S 1 0.2115 4.029 0.0000 0.000 Vertical Reactions - Unfactored Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 1.623 1.623 Overall MINimum 0.623 0.623 D Only 0.623 0.623 S Only 1.000 1.000 D+S 1.623 1.623 o M!1 Iulo If IF I 11 v110 z I I I I I gm� sx I a zl '� I I I I it it I' i I — Ii I rf I i I I I I I I — -- — 1 I I K — — — — — — — — — — — — — — ---" ME C C — SaR o StflUtNRAI SOLUTIAYS 7dD,--7 ,c2 eS A — o �-' •;` # �..'*��.•^� 6628 212th Strezt SI4, Sulte 205 lynnr. ood, WA IIIII Intake`3s55eng.com w rw.ssseng.com (425) 7M-1N, Amy TIMxn3t a is < E 9 Ardy Duffus Ln SS SOUND STRUC S RAL�OLUTIMS DAS Rf�� Edrvds, VIA Sol 212th st"et Sft, Suite 205 - Lymnne,,d, "A )IBC336 Aff� RkhW —..—g�. �425) 778- 02 I Ln M � { } s ( £ » §�/| 0 R \ \ \ \ ( PC 61