2014-0650 Lanzendorfer Covered Patio (City Builders).pdf
City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: July 18, 2014
TO: City Builders Inc.
Gordon Greggs
gordon@citybuildersinc.com
FROM: Andrew Gahan, Plans Examiner
RE: Plan Check: BLD2014-0650
Project: Lanzendorfer Covered Patio
Project Address: 9130 Cascade Drive
.
During a review of the plans by the Building Division for the above noted project, it was found that
the following information, clarifications, or changes are needed. A complete review cannot be
performed until the revised plans/documents, including a written response indicating where the
‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted
to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may
result in additional comments.
1.Please provide lateral engineering to show how wind and seismic loading upon the roof
structure will be transmitted into the earth.
2.Please provide a framing plan for the roof showing the configuration of the members and the
associated connections required.
3.Indicate the size and thickness of the footings supporting the posts.
4.Provide general dimensions describing the size of the structure proposed, and the locations
of supporting members such as posts and footings.
5.The 2x8 ridge board appears to be overstressed. Please provide engineering to verify
structural adequacy.
6.The 2x6 rafters appear to be overstressed. Please provide engineering to verify structural
adequacy.
7.Indicate the sheathing to be used at the roof. Include thickness, grade and the nailing pattern
from the sheathing to the framing below.
8.Clarify wher the Simpson H1 hurricane clips are to be installed.