2014-0664 Mosaic plumbing - Sager.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: July 29, 2014 TO: Bob Satko satko@comcast.net FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2014-0664 Project: Mosaic plumbing th Project Address: 130 5 Avenue S During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General Note: 1.Provide information for the ‘hair traps’ to be installed at the ‘head sinks’ per the tenant. The traps must be UPC/IAPMO listed. 2.Provide information verifying compliance with ASME 112.18.1/CSA B125.1 for the faucets and fixture fittings with hose connected outlets on the ‘head sinks’ per UPC 417.4. On sheets 1 and 2: 3.Indicate on the plans the waste and vent for the required drinking fountain located in the north walkway between ‘Studio 17’ and ‘Studio 18’. On sheets 3 and 4: 4.Indicate on the plans the water supply for the required drinking fountain located in the north walkway between ‘Studio 17’ and ‘Studio 18’.