20140707144709245.pdf21211TI 111U) AVENUE, SUITE 200 SFINI-1`11F, \VA 98121 A R C I I I T F CT 11 It F 206 -448-7580 FAX 4/18-8977 June 25th , 20,14 Leif 13jorback, Building Official City of Edmonds 121 5t" Avenue North Edmonds, Washington 98020 Re: Plan Check 2014-0331 Correction Response Mr. F3-jorback, The following are our Plan Review Correction Cornimrits responses: Sheet A0A 1. The project address was changed on sheet A0.1. 2. Total calculation revised on sheet AAA. 3. Code reference was updated on sheet A0A. 4. Occupant load was included and total updated on sheet A0.1. 5. M occupant load updated to ;i5 on sheet A0.1. Sheet AO.1 and A2.0 6. Second means of egress "person" doors were added to Tenant Spaces 3 & 4. Sheet A2.0 7, Door 103 changed to an outdoor swing. 8. "rhe dashed line indicates a security grill. 9. Door, signage note added to door schedule on sheet A6.0. Simet A4.0 10. Wall type 4 was added to sheet A6.0 showing details of translucent panel. Sheet A5.0 1 1."Foilet distance to wall changed to 18" Sheet A6.0 12. F)anic bar note added to door schedule. 13. Code reference updated. 14. Rafter bays are not concealed but are visually cab scored by a ventilate(] acoustical "cloud" or' panel, which is affixed to the structure. See revised ceiling type R1 on Sheet A 6.0 (attached). Our understanding is that this project COITIPlieS With WAG section %101.4.3 Exception 3. C 10 1.4.3 states that "' fhe following need not C01TIply provided the energy use of the building is not increased:" and lists several exceptioris related to our ceiling condition. Our proposed project does riot increase the energy USe of the building for the following reasons: 9,300sf of poorly iuSUlated heated space has been dernolished. This includes the removal of ii,icandes(,eritlrriecl''iani(,,aI ballast lighting and 6 very old and inefficient rooftop ITIeClIaniCal omits. . This shell and core project proposes the replacement of existing inefficient mechanical units with new energy efficient units. • Future lighting (pending TI packages) will include modern energy efficient lighting to replace the existing incandescent and mechanical ballast lighting. I While modifying the existing ceiling insulation is not part of the shell and core proposal, this project increasing the R -value Of Modified or new wall. A building vestibule is being installed. New and replaced energy efficient windows are proposed. While modifying the existing ceiling insulation is riot part of the shell and core proposal, this project is increasing the R. -value of modified or new wall. A building vestibule is being installed. New and replaced energy efficient windows are proposed. Sheet A7.2 15. Handrails returned to walls. Sheet SM 16. See attached response from Swenson Say Faget (structural engineer). GENERAL 1TArchitect's stamp added to sheets. 18. See attached response from Swenson Say Faget (structural engineer). 19. Emergency lighting note added to Exiting Diagram on sheet A0.1 . Exit signage added to Floor Plan on sheet A2.0 20, Interior, Lighting Summary and design drawing enclosed. 21. Special Inspection form filled out and attached. Sinr ce ly Jeff J, ief :genic r Architect Jo'hnson Ar-chitectu (., and Planing I, MOM 1114 A '� 1( Ft (J (' ( U 11 '1, A L E H (5 1 r4 E E H � lil G C� 0 F1 F0 � I )",I � 0 1 June 6111, 2014 Homero Nishiwaki Johnson Architecture and Planning 2124 3rd Ave. Ste 200 Seattle, WA 98121 RG: Salish Crossing; 190 Sunset Ave. S. Plan Review Comment Response; Plan Check: 2014-0331 Dear 1-lomero; We are in receipt of the plan check comments from the City of Edmonds for the Salish Crossing project and have addressed the structural items as follows: Item 16: Sheet 53.1 Comment: In detail 11, several dimensions do not match those shown in the structured ecdcuhtfions. Please reconcile the plans and the calculations tojustify the design shown on the plans. " SSF Response: Calculations showed a baseplate detail with 7/8" diameter bolts x 18" long and spaced 6" apart. This connection is designed to resolve shear forces from each of the frame members. The maximum shear force for this connection was calculated as 10.34kips. The plans were detailed with 3/4" diameter bolts x 12" Tong and spaced S" apart. See attached calculation for the verification of this design. The spacing of the bolts have further been changed to 3- 3/4inches apart. We trust this addresses all the structural issues. Please let us know if you have any questions or if we call be of further service. Sincerely, SWENSON SAY FACET, INC. A Structural Engineering Corporation Blaze Bresko, PE, SE Principal 2124 31d Ave Suite 100 Seattle, WA 98121 ph :( 206),143-6212 fax :( 206) 443-4870 www.swensonsayfaget.com