2014-0791 Brigid's Bottleshop TI - Brandt Design.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 10, 2014 TO: Brian Palmberg brian@brandtdesigninc.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2014-0791 Project: Brigid’s Bottleshop TI Project Address: 190 Sunset Avenue S, Suite 207 During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General note: 1.Separate permits/submittals are required for the following: a)Mechanical b)Plumbing/gas piping c)Fire Alarm d)Fire Sprinkler On sheet A0.0: 2.General Information a.Project Address – Change the suite number from ‘C’ to ‘207’. b.Project Description – Change the designated occupancy type from ‘B’ to ‘A-2’ per IBC 303.3. c.Occupancy – Change the designated occupancy type from ‘B’ to ‘A-2’ per IBC 303.3. 3.Occupant Load Calculations d.Change the table reference from ‘1004.1.1’ to ‘1004.1.2’. e.Clarify the amounts of area noted for rooms ‘101’, ‘102’, ‘106’, ‘E1’, and the ‘concentrated’ area in front of the bar. They appear to be less than the anticipated ‘net’ and ‘gross’ areas as defined in IBC section 202. f.Indicate on the plans the occupant load for the ‘concentrated’ area in front of the bar. 4.Detail 3 – Egress/Occupancy Plan g.Clarify the amounts of area represented for rooms ‘101’, ‘102’, ‘106’, ‘E1’, and the ‘concentrated’ area in front of the bar. They appear to be less than the anticipated ‘net’ and ‘gross’ areas as defined in IBC section 202. h.Change the direction of the door ‘swing’ to that in the direction of egress travel per IBC 1008.1.2. On sheet A0.1: 5.General Notes i.In the first note from the top, change the code from ‘Residential’ to ‘Building’. j.In the third to the last note, change the code from ‘Seattle’ to ‘Washington State’. On sheet A1.0: 6.Detail 1 – Floor Plan k.Change the direction of the door ‘swing’ to that in the direction of egress travel per IBC 1008.1.2. On sheet A1.1: 7.Detail 1 – Equipment/Furniture Plan a.Indicate on the plans the means to be used to provide an accessible sales and service counter per ICC A117.1-2009 section 904.3. On sheet A6.0: 8.Detail 1 – Building Section a.Indicate on the plans the means to be used to provide an accessible sales and service counter per ICC A117.1-2009 section 904.3. Page 2 of 2