Loading...
20140904162522801.pdfAugust 28, 2014 RJA Mr. John J. Westfall, Fire Marshall ARCHITECT City of Edmonds, 17710 DETROIT AVENUE Office of Fire Marshall LAKEWOOD, OHIO 44107 th PHONE(216) 521.5134 121 J Avenue N. FAX (216) 5214824 Edmonds, WA98020 Regarding: Harbor Freight Tools Edmonds, WA BLD2014-0693 Our Project No. 14145 Mr. Westfall, The following list describes revisions made to the drawings in response to the plan review comments received for the above referenced project. Revisions to the drawings have been clouded and are marked with delta #1, labeled' Bulletin #1 dated 08/28/14. 1 a.) The existing fire separation wall will have (1) additional layer of 5/8" Type `X' gypsum board laminated to each side to achieve the 2 hour fire rating per the required minimum fire separation per Table 707.3.10. The (2) new fire shutters were revised from 1 hour fire rating to a 1-1/2 hour fire rating.' 1 b.) A new door has been added to the south side of the building next to the restroom area, (Door #14, Sheet Al. 1). The door shall be a 1-1/2 hour rated hollow metal door and frame assembly due to the fact that the south wall is a 2 hour fire rated assembly. 1 c.) There will be no high pile storage in this building. There is a suspended ceiling through out the building at 10'-0" a.f.f. The sales area racking height is 7'-0" a.f.f. to the top of the highest shelf with merchandising not exceeding 8'-0" a.f.f. The sales replenishment area racking to shelf is at 8'-0" a.f.f. 2.) Acknowledged — the deferred fire alarm submittal shall show existing devices, calculations and specifications per NFPA 72. 3.) See attached material for the Hazardous Materials Inventory Statement. 4.) Acknowledged — a 4" yellow bar shall be painted under the fire -rated shutters opening, (see Sheet Al. 1) 5.) This is a storage area on the exterior of the building for the propane canisters that are used by the fork lift. 6.) Acknowledged — spot smoke detection shall be provided for fire shutter activation. Fire Shutters have been changed to"'M100 Fire Doors" by Cornell Iron in lieu' of the °FireGuard Doors as originally specified. 7.) Emergency lighting system is designed to meet the standards of the 2012 International Building Code and 2014 National Electrical Code at all egress paths, including directly outside of exit doors. Fixture Types AE, BE, DE, EM 1, EM2_and EM5 are exit/ emergency fixtures with integeral batteries. 8.) Acknowledged. See revised sheet E2.0. 9.) Acknowledged — Knox Box shall' be provided and location shall be approved by Fire Marshall prior to installation: 10.) See Item 1c above: I believe the attached corrected drawings and the correspondence above are appropriate responses to the plan review letter. Please contact me directly if you have any questions or if there is further information needed to expedite permit approval. It= M-MIMITOIT, =I Qty of Edmonds Office m[Fire Marshall August 28.2O14 Edmonds, WA Our Project No. 14145