2014-0907 Scratch Distillery.pdf
City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: October, 2014
TO: Mark Ward
Urbanadd Architecture +Design
Email: mward@urbanadd.com
FROM: Leif Bjorback, Building Official
RE: Plan Check: 2014-0907
Project: Scratch Distillery
Project Address: 190 Sunset Avenue
During review of the plans for the above noted project, it was found that the following information,
clarifications or changes are needed. Please provide written responses as to where the changes can be
found on the plans, and submit revised plans/documents to a permit coordinator in the Development
Services Department. Thank you.
1.Architect, please stamp and sign all plan sheets.
2.Will there be a customer counter for retail sales? If so, please show on the plans, and indicate
the height of the counter to comply with accessibility requirements. IBC 1109.12.3 and ICC
A117.1 section 904
3.Reference Door 101C and Window W1 on sheet A2.0 and A5.0. As per IBC 707.6 #3,
oenings in the fire barrier wall are limited to 25% of the length of the wall unless tested to the
standards of ASTM E119 or UL263 and carry a fire resistive rating equal to that of the wall (1
hour). Please change the window rating from 45 to 60 minutes, and note the proper standard
in the schedule; or revise the design to conform to the maximum 25% opening length.
4.Provide a design for the seismic anchorage of all equipment weighing greater than 400
pounds. The design must be by a Washington state licensed engineer. This may be a deferred
submittal; in which case indicate so on the plans.