2014-0907 Scratch Distillery.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October, 2014 TO: Mark Ward Urbanadd Architecture +Design Email: mward@urbanadd.com FROM: Leif Bjorback, Building Official RE: Plan Check: 2014-0907 Project: Scratch Distillery Project Address: 190 Sunset Avenue During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.Architect, please stamp and sign all plan sheets. 2.Will there be a customer counter for retail sales? If so, please show on the plans, and indicate the height of the counter to comply with accessibility requirements. IBC 1109.12.3 and ICC A117.1 section 904 3.Reference Door 101C and Window W1 on sheet A2.0 and A5.0. As per IBC 707.6 #3, oenings in the fire barrier wall are limited to 25% of the length of the wall unless tested to the standards of ASTM E119 or UL263 and carry a fire resistive rating equal to that of the wall (1 hour). Please change the window rating from 45 to 60 minutes, and note the proper standard in the schedule; or revise the design to conform to the maximum 25% opening length. 4.Provide a design for the seismic anchorage of all equipment weighing greater than 400 pounds. The design must be by a Washington state licensed engineer. This may be a deferred submittal; in which case indicate so on the plans.