Loading...
20140916101212392.pdfMARK &JILL DEMARAY 505 TENTH AVENUE NORTH EDMONDS, WASHINGTON 98020 (425)771-6453 EMAIL: markdemaraya msn.com September 15, 2014 Chuck Miller, Plans Examiner City of Edmonds Building Division 121 5t" Ave N. Edmonds, WA 98020 RE: Plan Check: BLD2014-0698 — Corrected Plans Project: Demaray addition Project Address: 505 10th Avenue N Dear Chuck: Please find delivered herewith a set of corrected plans for my proposed addition. I believe we have made the corrections that you requested in your letter of August 19. A more detailed examination of the existing structure was undertaken with a great deal more drywall removed to expose the existing framing which revealed a number of existing engineered trusses that were not noted in the previously submitted plans. Please contact me if you have any further questions. Thank you for your time and consideration. fiery Truly Y'urs, AI< Mark M. De"maray ' 4h 1l'r'sIF, ;,,y, T("" f , "y' RESPONSE AND REVISION 11 September i Response to Ch cl Millerg Plans Examiner RE: Plan Check: BLD2014-0698 Project: Demaray addition Project Address: 505 10th Avenue N During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the `clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General Note — Indicate on the plans the option to be selected to achieve the required 0.5 credits per WSEC R406. See note on Sheet A-1 indicating the flan for this credit 'hi hli hte in yellow) On sheet A--1: General Notes - Change the code year reference from `2009' to `2012' for the following: a. Note #1 - correction made (highlighted in yellow) b. Note #4 - correction made (hila.,hli hted in yellow) 2. Floor Plan — Indicate on the plans the following: a. The required smoke alarm per R314. - correction made (hi-hli Ated in yellow) b. The required carbon monoxide alarm per R315. correction made (hi hli�hted in yellow 3. Framing Plan An additional more detailed examination of the structure was undertaken with much more drywall removed to expose the existing framing which revealed errors in the previously submitted plans for the existing structure. In fact, engineered trusses are in present and in place that were not known or noted in the original plans. 'These existing trusses are now highlighted in the framing plan as noted on Sheets A-1 and A-2, as well as structural calculations for the loads in the areas noted in paragraphs a b, c, and d below. a. Clarify the callout for the `Existing Beams A' — 2x10 tripled joist — to be used to support the loads from the walls and roof framing above the `Office'. They appear to be over spanned, fail in bending, and deflect beyond that allowed per Table R301.7. The uniform loads used in the provided structural calculations do not appear to reflect those anticipated by the represented construction and are a bit low. The wood species used in the provided structural calculations (Douglas Fir -Larch #2) is different than that noted in the `General Structural Notes' (Hem Fir #2). See highlighted framing plan showing existing trusses and new calculations with existing trusses in this area. b. Clarify the callout for the `HU210-3' joist hanger to be used to support the `Existing Beam A' — 2x10 tripled joist. Per the manufacturer it appears to be unable to support the loads anticipated by the represented construction. See highlighted framing plan showing existing trusses and new load calculations with existing trusses in this area as well as planned hanger. c. Indicate on the plans the required connection to support the loads at the ends of the`Existing Beam A' — 2x10 tripled joist — where not specified to guide proper construction and inspection. See highlighted framing plan showing existing trusses and new load calculations in this area d. Clarify the callout for the `Existing Beam B' — 2x10 tripled joist — to be used to support the loads from the floor, the two `Existing Beams A', and the wall and roof framing above the 'Office'. It appears to be over spanned, fails in bending, and deflects beyond that allowed per Table R301.7. The uniform loads used in the provided structural calculations do not appear to reflect those anticipated by the represented construction and are a bit low. The point load from the east `Existing Beam A' does not appear to have been accounted for. The wood species used in the provided structural calculations (Douglas Fir -Larch 42) is different than that noted in the `General Structural Notes' (Hem Fir #2). ) See highlighted framing plan showing existing trusses and new load calculations in this area On sheet A-2: 4. Section AM a. Change the required wall insulation from `R-19' to `R-21' per WSEC Table R402.1.1. - correction made (highlighted in yellow) b. Indicate on the plans the required sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening per R310.1. - correction made (highlighted Jin yellow)