2014-0918 Hall (Hall).pdf
City of Edmonds
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: October 3, 2014
TO: Keith Hall
Rhall_55@yahoo.com
FROM: Andrew Gahan, Plans Examiner
RE: Plan Check: BLD2014-0918
Project: Hall Remodel/Repair
th
Project Address: 23405 84 Avenue W.
During a review of the plans by the Building Division for the above noted project, it was found that
the following information, clarifications, or changes are needed. A complete review cannot be
performed until the revised plans/documents, including a written response indicating where the
‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted
to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may
result in additional comments.
General Notes:
1.Please provide page numbers on the drawings to help guide proper review, construction and
inspection.
Sheet 2:
2.Please provide engineering for the framing members selected. It appears that each of the
members selected (e.g. 2x6 rafters and 2x8 ridge) are all overstressed.
3.Indicate the proposed spacing of the rafters on the plans.
Sheet 3:
4.Indicate on the plans the beam to be selected for use to support the low ends of the rafters.
5.Please provide engineering for the framing members selected. It appears that the rafters
exceed the deflection limits set forth in the IRC and the ridge beam is overstressed.
Sheet 4:
6.Reference the details where appropriate on the framing plans.
7.Specify connections at rafter supports/struts as necessary.
Sheet 5:
8.Specify the size of the footings (piers) required at the porch roof support posts.