2014-0918 Hall (Hall).pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 3, 2014 TO: Keith Hall Rhall_55@yahoo.com FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2014-0918 Project: Hall Remodel/Repair th Project Address: 23405 84 Avenue W. During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General Notes: 1.Please provide page numbers on the drawings to help guide proper review, construction and inspection. Sheet 2: 2.Please provide engineering for the framing members selected. It appears that each of the members selected (e.g. 2x6 rafters and 2x8 ridge) are all overstressed. 3.Indicate the proposed spacing of the rafters on the plans. Sheet 3: 4.Indicate on the plans the beam to be selected for use to support the low ends of the rafters. 5.Please provide engineering for the framing members selected. It appears that the rafters exceed the deflection limits set forth in the IRC and the ridge beam is overstressed. Sheet 4: 6.Reference the details where appropriate on the framing plans. 7.Specify connections at rafter supports/struts as necessary. Sheet 5: 8.Specify the size of the footings (piers) required at the porch roof support posts.