Loading...
20140924170257216.pdfBYKONEN CARTER QUINN STRUCTURAL ENGINEERING Date: September 18", 2014 To: Aspects Inc. 15617 37" Ave. NE Lake Forest Park, WA 98155 Attn: James Musar From: Ri Han Project: Stoulil Residence Project #: copy to: File th Below are the structural response to the plan review comments, dated September 12 2014. Our responses correspond to the Building Division comment numbers. 8. Header #5 has been removed from the plan and the calculation is no longer valid. 9. Main floor beam #4 has been revised to show the worst case loading condition of th'; garage floor joist. The calculation is attached, and the plan reflects the beam size change. 10. Main floor beam #7 has been revised to include e thpoint load from upper floor bea calculation is attached. i I 111111!11rq� 11111111iiiiiiir; 11� 1, 13. The calculation is attached showing upper floor beam #4 as L 3 Y2 x 11 7/g. 14. /8- 14. The calculation is attached showing upper floor beam # 6 as L 3 % x 11 7/8 with 4% feet of tributary area. 15. The point load on upper floor beam #7 has been revised, and the calculation is attached, 16. The maximum allowable notch, as calculated, gives a dn of 5.28 inches. Detail D allows for a notch less than the allowable notch, giving a do of 7 % inches. The detail does not need to be revised, as structurally we do not want the d, value to be less than 7 inches. P� 820 John Street #201 Seattle, WA 98109 206-264-7784 www.BGQ-.SE.(;on1 1-f "'V il;lr! Fall