2014-0943 Post Office plumbing - Emerald City-Best.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 16, 2014 TO: Best Plumbing Group, LLC cindys.s@bestplumbing.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2014-0943 Project: Post Office plumbing nd Project Address: 130 2 Avenue N During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. On sheets P2.00, P2.01, P2.02, P2.03, P2.04, and P2.05: 1.Storm Drain Sizing Note – Change the table reference from ‘11-2’ to ‘1101.7’. On sheet P2.00: 2.Basement Plan a.Change the square footage noted at the 6” rain leader at gridline ‘B/3.15’ from ‘13775’ to ‘13415’. b.Change the square footage noted at the 6” rain leader at gridline ‘A/2.25’ from ‘16150’ to ‘15790’. c.Clarify the difference in the water supply connection shown and that required and represented on separately submitted drawings under permit BLD2014-0074. While it provides adequate supply for the proposed domestic plumbing fixtures, it may not when also connected to the required fire sprinkler system. On sheets P2.01, P2.02, P2.03, P2.04, and P2.05: 3.Indicate on the plans the required venting for the plumbing fixtures represented in the quadrant bounded by gridlines ‘F.25’ and ‘3.1’. While some appear to be shown, the venting of many fixtures, such as those identified in that area as ‘11’, ‘16’, and ‘17’, is not represented. On sheet P2.03: nd 4.2 Floor Plan – Change the ‘waste/vent riser identifier’ at gridline ‘B.5/3’ from ‘2’ to ‘12’. On sheet P2.04: rd 5.3 Floor Plan – Change the ‘waste/vent riser identifier’ at gridline ‘B.5/3’ from ‘2’ to ‘12’. rd 6.3 Floor Plan – Change the ‘water supply riser identifier’ at gridline ‘B/3.3’ from ‘Q’ to ‘D’. rd 7.3 Floor Plan – Change the ‘water supply riser identifier’ at gridline ‘B/4.2’ from ‘P’ to ‘F’. On sheet P2.04 and P2.05: 8.Indicate on the plans the venting for the ‘future’ plumbing fixtures represented on sheets ‘P2.02’ and ‘P2.03’ at gridline ‘C/2.5’. On sheet P4.00: 9.Waste and Vent Riser Diagrams a.Diagram #10 – Change the fixtures identified from ‘BA’ to ‘CW’. b.Diagram # 15 – Change the ‘flag note’ identifier from ‘3’ to ‘2’. 10.Horizontal Wet Venting Notes a.Note #1 – Change the code section from ‘908.2.1’ to ‘908.2’. b.Note #3 – Change the table reference from ‘10-1’ to ‘1002.2’. c.Note #6 - Change the table references from ‘7-3’ to ‘702.1’ and from ‘7-5’ to ‘703.2’. 11.Trap Arm Notes – Change the table reference from ‘10-1’ to ‘1002.2’. 12.Flag Notes – Clarify the reference to ‘DWG P4.02, Detail 10’ for piping of suds producing fixtures. Sheet ‘P4.02’ could not be found among the submitted construction documents. Page 2 of 2