2014-1014 Augusta Plan (Pacific Ridge).pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: November 12, 2014 TO: Brandi Neal Pacific Ridge Homes bneal@pacificridgehomes.com FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2014-1014 Project: New SFR th Project Address: 22303 95 Place W. b During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. Non-structural Items Sheet 3A 1.Detail F26 – please associate the arrows with their respective text. 2.Add note to water heater in garage: “0.62 minimum EF per WSEC Table 406.2 – Option 5a.” Sheet 7 3.Either eliminate Bedroom 5 as an option, or add a smoke detector per IRC R314, and verify egress per R310. 4.Verify that the window by the stairs will be safety glazing per IRC R308.4. Structural Items Sheet 4 5.Specify the floor joists to be used at this level. Sheet 6 6.The floor joists at the rear half of the structure have been specified, but the floor joists at the front half of the building appear to have a different spacing and have not been specified. Sheet 8 7.Clarify the configuration and points of bearing at the girder trusses across bedrooms 2 and 3. It appears they are bearing at interior, unsupported locations unless they were meant to bear on girder perpendicular girder trusses. Additionally, the plans do not reflect what is shown in the engineering packet. Page 2 of 2