2014-1038 Salt and Iron.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: November 3, 2014 TO: Salt & Iron LLC Email: feedme@bardojo.com FROM: Leif Bjorback, Building Official RE: Plan Check: 2014-1038 Project: Salt & Iron Cafe Project Address: 321 Main During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.Provide a copy of the Snohomish Health District (SHD) plan review letter. Any issues raised within that review letter must be incorporated into the plans submitted to the city and reviewed prior to issuance of the city building permit. 2.On the list of deferred submittals: a.Remove the reference to Plumbing b.Add Type 1 hood 3.Show on the drawings or provide a separate lighting plan indicating light fixture locations and wattage matching that shown in the Interior Lighting Summary form submitted with the application. 4.Revise the occupant load calculation to reflect the correct occupancy group (either A2 or B depending on total occupant load) and use the following square footage factors: 15 sf/person for customer seating area; 7 sf/person waiting area; 200 sf/person for kitchen/prep area. Also, clarify whether the bar seats are fixed or non-fixed. For non-fixed bar seats, use a factor of 18 linear inches of counter per person, and include this in the total calculation. IBC 1004 5.Indicate on the plans to post the occupant load. IBC 1004.3 6.In order to verify gas pipe size, show on the plans the size and length of each piping branch, and provide the BTU ratings of all gas fired equipment, including the water heater in the basement. 7.The meat sink is noted to indirectly drain to the grease trap, but the drawings appear to show the drain as routed to the floor sink. Please show the meat sink indirectly draining to the grease trap. 8.The veg sink and hand sink drains are shown connecting to the meat sink drain which is not allowed. Please show these two drains discharging into the floor sink. 9.Show the location of the Type 1 kitchen hood on the plans. 10.A Type 2 exhaust hood is required over the warewasher and dishwasher if they produce heat or steam. Provide manufacturer specifications on these appliances. Provide details and CFM for the hoods. If the appliances do not produce heat or steam, provide, for city review, documentation from the manufacturer stating the the reason why a Type 2 hood is not required. IMC 507.2.2 11.On the plumbing page, what is “ED?”