20141106154738797.pdfDATE PLAN REVIEWCOMMENTS BUILDING DIVISION (425) 771-0220 September 25, 2014 TO: Jim Scribner c/o Tom Leren The Leren Company, Inc. FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2014-0904 Project: Scribner ADU Project Address: 19905 88"' Avenue W. r:r.,ifff.� rGW(,,,,d hr;lov, Gr( "t, rd. 2,urar�;, fcr Ihr; Vo k r rE During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the `clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General Comments: �,J oyes =end GA 1. Please indicate on the plans which fire -rated assemblies will be utilized to obtain the <IG� ruttmher. ht,i (" minimum 1 -hour fire rating to separate the two dwelling units per IRC R302.2, etc. Indicate dr y,m det,0 for each fire -resistive element (i.e. floor/ceiling, wall, etc.) the listed and tested design x /Vs rind aofloor number (e.g. WP 3644) and the fastener size and spacing. This is to facilitate effective plan plrin r'r, hidi nto d review, installation and inspection of these assemblies. 2. Indicate on the plans that supporting framing (i.e. beams, bearing walls, etc.) for the fire R ­'I I H ,rated assemblies referred to in item 1 above, shall be protected in accordance with IRC wvk�d wj ch.mdod; R302.3.1, etc.) rGnPa m kb""d to 3. Note on the plans that all through penetrations and/or membrane penetrations shall comply with IRC R302A. 4. Indicate on the plans the location of the water service shut off valve (UPC 605.2), water heater (R306.4), natural gas service shut off valve (62420.1.3) and electric service "o 1'`' ``"`'e`en° floor disconnect [NEC 230.72(Q. They must be equally accessible at all times to occupants of "l" ' ` "k"m "J VV1 I both dwelling units per the code sections indicated. It should be noted that in each case, a " i °' � notan"', separate system could be employed in each dwelling unit as an alternative. 5. Indicate on the plans the means to be used to provide comfort heat for the ADU per R303.8. �`:"�` "�"''o There must be at least one thermostat in the ADU to regulate the temperature per WSEC ��A3 ,,dki" "� �� �,rv��r' 503.8.3.2. rru" l.ioll A th rmr 'JA ()�r ,Hooi {"l�m