2014-1165 Heslop (Shapiro-Basri).pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: December 19, 2014 TO: Tony Shapiro AD Shapiro Architects FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2014-1165 Project: Heslop Remodel/Addition rd Project Address: 652 3 Avenue N. During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. Please note that the non-conforming condition of this structure requires adherence to the Edmonds Community Development Code (ECDC) Section 17.40.020. The aforementioned ECDC code section limits the remodel to 75% of the replacement cost if it is desired to continue use of the structure in the non-conforming condition. General 1.Please provide a foundation plan. Sheet A201 2.Specify safety glazing at the window to the side of the master bedroom door, and at the sidelight windows at the kitchen door per IRC R308.4. 3.Specify the size of each exhaust fan in the bathrooms, laundry room and kitchen per IRC Table M1507.4. Additionally, specify the size, location and method of achieving whole house ventilation per IRC M1507. 4.Please specify that the door leading from the garage to the house is self-closing per IRC R302.5.1. 5.Revise or remove the detail bug pointing to the Powder Room. Sheet A202 6.Specify safety glazing at the windows to the side of the Living Room exterior door, above the toilet in Bath 2, at the sidelights adjacent to the door in Bedroom 3, and the window in Bath 1 per IRC R308.4. 7.Specify the size of each exhaust fan in the bathrooms, laundry room and kitchen per IRC Table M1507.4. 8.Revise the door schedule to specify the self-closing door per item #4 above. Sheet A301 9.Revise the detail bug to reference the correct detail at the upper left corner of Section 1. Sheet A302 10.Revise the window schedule to identify all safety glazing and egress windows. Sheet A401 11.Revise the ceiling insulation to R-38 (instead of R-39). Calculations 12.Sheet 12 a.Wall TF was omitted from the analysis. Please revise the calculations to show wall TF. b.The calculations at wall TA do not match the plans. Please reconcile the calculations to match the plans. c.The overturning force shown at wall TA exceeds the tabulated capacity for STHD10/10RJ holdowns in the Simpson catalogue. Please select a holdown with adequate capacity. d.The overturning force shown at wall TE exceeds the tabulated capacity for HDU5 holdowns in the Simpson catalogue. Please select a holdown with adequate capacity. e.Please justify the use of a 1.15 live load reduction in analyzing the floor beams. f.It appears the no live load was applied to beam B2-4. Please revise. g.Beam B2-3A could not be located on the plans. Please advise. Sheet S-1 13.To avoid confusion in reading the unconventional layout (typically, the roof framing plan is drawn with the upper floor plan, the upper floor framing plan with the main floor plan, etc.), please revise the title of 1/S-1 to ‘Main Floor Plan/Main Floor Framing’. Sheet S-2 14.Per item #13 above, please revise the title of 1/S-2 to ‘Upper Floor Plan/Upper Floor Framing’. 15.Per item #13 above, please revise the title of 2/S-2 to ‘Roof Framing Plan’. Page 2 of 2