2014-1165 Heslop 2 (Shapiro-Basri).pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: February 18, 2015 TO: Tony Shapiro AD Shapiro Architects FROM: Andrew Gahan, Plans Examiner nd RE: Plan Check: BLD2014-1165 – 2 Review Project: Heslop Remodel/Addition rd Project Address: 652 3 Avenue N. During the 2nd review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. 1.Comments 1-11: OK Calculations 12.Sheet 12 a.OK b.OK c.The overturning force shown at wall TE exceeds the tabulated capacity for HDU5 holdowns in the Simpson catalogue. Please select a holdown with adequate capacity. The overturning force listed on page 12 of the original calculations show that the overturning load to be resisted at wall line TE is 8.18 kips. The capacity for the downsized HDU4 listed on 11 shows that the maximum capacity of an HDU4 holdown is 6391# for seismic and 7304# for wind, both of which are exceeded. In addition, the capacities shown on sheet 11, as increased for LRFD design method appear to correlate with the values listed for Douglas Fir #2. Please upsize the holdown as needed and verify that the framing to which the upsized hardware will be fastened will be DF#2 or better. d.OK e.OK f.OK 13.Comments 13-15: OK See Additional Comments on the next page. Additional Comments As previously noted, the non-conforming condition of this structure requires adherence to the Edmonds Community Development Code (ECDC) Section 17.40.020. The aforementioned ECDC code section limits the remodel to 75% of the replacement cost if it is desired to continue use of the structure in the non-conforming condition. With regard to the above statement involving ECDC Section 17.40.020, inconcistencies were found between the chart entitled ‘Percent of Exterior & Interior Walls Reused in the Final House’ (the chart) and 3/A102 – ‘Ext/Int Wall Reuse and Demo Floor Plan’ (the demo plan): a.North Wall Grid 3 – 22 lineal feet (LF) remaining on the chart, but only about 11’ shown to remain on the demo plan. b.East Wall Grid E – 20.25 LF remaining on chart, 14’ on demo plan. c.East Wall Grid D – 21.13 LF remaining on chart, it appears that the entire wall line will be demolished. d.South Wall Grid 4 – 39.75 LF remaining on chart, 22’ on demo plan. e.West Wall Grid B – 10 LF remaining on chart, 3.5’ on demo plan. Please revise the plans and/or cost estimate as needed. Page 2 of 2