Loading...
2015-0172 Schultz Deck.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: February 13, 2015 TO: Brian and Kelley Schultz kelleyls@amazon.com FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2015-0172 Project: Deck Rebuild Project Address: 1040 C. Avenue S. During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. Structural Comments 1.It appears that the 4x12 HF#2 deck beam is overstressed in bending and exceeds the allowable length to deflection ratio. The beam was checked at 14’ span with 2’ cantilevers at each end. Please upsize the beam or provide calculations supporting the beam selected. 2.Please specify the dimensions between posts for each length of deck beam to help guide proper review and inspection. 3.Page 2/5 has a note referring to beam calculations, yet no beam calculations were provided. Please clarify.