Subject: Plan Check: 2012-0455, Revision #1 - Starbucks at 9801 Edmonds Way
Dear Leif,
VVereceived your comments regarding our store at the address referenced above and submit the following
response. Your comments are listed below as presented to us with our response in italics immediately
below.
1. Reference sheet G-0001: The original approved project plans were designed under the 2009 codes.
The revised plans reference the 2012 codes, and as such, this review has been performed assuming
the 2012 codes govern the design. Please confirm that this is your desire and intent.
Response: Our desire and /ntent/orthe codes governing this design btoutilize the 2012codes os
2. Reference sheet G-0001: Construction type 11-B is called out on this sheet. Combustible materials
are not allowed in type 11-B unless noted in the exceptions in IBC 602.2. On sheet S.001 the
Shearwall notes specify non fire rated sheathing which is not allowed. Please revise the plans as
needed tujustify the materials proposed inthe design.
Response: Please see the structural response
l Reference sheet A-1501: A 42 inch guard is required near the roof hatch where the hatch is within
10 feet of roof edge. IMC 304.11
Response/ Please refer toDetail 3onsheet A`2502showing oguard rail near the roof hatch /n
accordance with IMC 3O4.12and /8[1D1I6
4. Reference sheet A-5008: In detail 1,
o. increase the width of the access aisle to 96 inches or the width of the parking stall to132
inches. ICC A117.1section GO2.2.
b. Show the bottom of the accessible parking sign at 60 inches height. ICC A1.17.1 section
502.7.
Response: Please review sheet A`5O08: detail 1,
o Please refer tonew sheet C4.1Water and Sewer Plan. /n compliancewith conversations
with Jeannie McConnell, wehave superimposed A4JH7D2821vehicle maneuvering
diagrams indicating adequate vehicle drive aisle accessibility with the current design.
b. The bottom of the accessible parking sign has been revised to note 60 inches height per ICC
A1271section 582.7
5. Reference sheet A,6OO8: |ndetail 3,show the main section ofthe curb ramp aa44inches inwidth.
IBC 11O1.Z2VV6amendment.
Response: Sheet A-5008: detail 3has been revised to indicate 44 inches inwidth atthe main section of
the curb romp per 113C 1101.2.2 WS amendment.
6. Reference sheet A-5001: Please provide calculations and design details for the seismic anchorage of
rooftop equipment weighing more than 400 pounds. (RTU -1 and RTU -2) The documents must be
stamped and signed by a Washington state licensed engineer. ASCE 7-10, section 13.1.4 (see
attached)
Response: Please see the structural response (attached).
7. Please complete and submit the Washington State energy forms for Interior and Exterior lighting
found onthe www.neec.net website. Ensure that the information onthe forms iscoordinated with
the lighting designs onthe plans.
Response: Please see the attached completed Washington State Interior and Exterior Lighting Summary
forms. The information has been coordinated with the lighting design on the oknnc
8. Special inspections have been identified as being required for this project. Please complete and
return the attached special inspection agreement forms.
Response: Asrequested the special inspection ug/ecn/enthxnohove been completed. Please see
attached.
IVIL REVIEW - GENERAL
The letter of 11/20/2014 from Jeanie McConnell to Bill Ruecker delineated civil engineering
p|ancheckcommen1s.
Response: Civil Engineering comments have been noted and responded to/nthe Civil
Engineering's Comment Response letter (attached).
Please let me know if you require any additional information to complete your review of this project.
Sincerely,
�
�
EhcRamdng
Architect —
10202 5th Avenue NE, Suite 1.02 1 Seattle, WA 98125 1 p 206.547-1940 1 expect a difference I
Armour .Tri sderfer Engineering Inc., P.S.
555 116"' Avenue NE, Suitel 18, Bellevue, WA 98004-5233
Phone (425) 614-0949 Fax (425) 614-0950
December 16, 2014
Eric Ramsing
KDW Salas O'Brien
10202 Fifth Avenue NE Suite 300
Seattle, WA 98125
10=1=11
Plan Check No: 2012-0455, Revisions
AUE No.: 14157 1
The following is a response to the plan review comments in the letter dated 11/7/2014. Plan
review questions are in italics, with our response in plain text. Responses to unreferenced
comments are by others.
2. Reference sheet G-0001: Construction type 11-B is called out on this sheet.
Combustible materials are not allowed in type 11-B unless noted in the exceptions in IBC
602.2. On sheet S.001 the Shearwall notes specify non fire rated sheathing which is not
allowed. Please revise the plans as needed to justify the materials proposed in the
design.
The shearwall notes on sheet 5.001 have been updated to reflect the usage of fire
retardant treated wood sheathing.
6. Reference sheet A-5001: Please provide calculations and design details for the seismic
anchorage of rooftop equipment weighing more than 400 lbs. (RTU -1 and RTU -2) The
documents must be stamped and signed by a Washington state licensed engineer.
ASCE 7-10, section 13.1.4.
Detailing for RTUA and RTU -2 is shown in details 8, 9 & 10/S-004. Additional
calculations supporting the previously shown connection details are included in this
submittal.
Please feel free to contact us if you have any questions or comments.
Sincerely,
Armour Unsderfer Engineering Inc., P.S.
Karen M. Stoner
Project Engineer