20150202124851087.pdfJanuary 15,2O15 ENGINEERING Jeanie McConnell, Engineering Program Manager City of Edmonds � "« 121S Ave N2 Floor Edmonds, WA 98020 RE: Application Number: bN2O12U4GS Project Name: Stadnuoks—Revision from Bank toS1a/bucks Project Address: 9801 Edmonds Way Dear Jeannie, Itemized below isour response tothe review comments inthe November 2O,2014review for the above referenced project. Our response appears in bold. GENERAL 1. Please provide an itemized engineers cost estimate, including units and unit prices, for both on -site and off -site (right-of-way) improvements, including traffic control. The City necommendsuse ofthe King County Site Improvement Bond Quantity VVorksheet. Please utilize the King County Site Improvement Bond Quantity VVu/ksheettocomplete the estimate. o A bond is required to be placed for all right-of-way improvements. The amount of the bond will be based on 120% of the City approved estimate for all right of way improvements. The City will inform you of the appropriate bond amount after review ofthe cost estimate. Bond forms can beobtained from Permit Coordinators Linda Thornquist or Kristin Johns at 425-771-0220 or by email at or ' o inspection fees for this project will becalculated at3.3%ofthe 120%Chv approved estimate for all improvements. AKing County bond quantity spreadsheet has been completed. Bond payment will be coordinated by the applicant. 2. Please include City ofEdmonds approval block. The approval block has been added to sheet C1.1 l Clearly indicate landscape strip between curb and sidewalk on civil construction plans and show location ofstreet trees. Trees have been added tuthe civil plans, aswell ws ataUout for the existing landscaping strip. Starbucks Edmonds Comment Response January 15, 2015 Page 2 of 5 STORMWA+TER REPORT The design of the existing stormwater system that serves the Walgreens site was designed to include runoff from the site to the west that is now proposed as a Starbucks. The original design assumed a bank with drive -through lanes on the site of the proposed Starbucks. Please provide the following information for only the Starbuck site: ITEM Originally Currently Proposed Change from Proposed w/ Bank w/ Starbucks Originally Proposed Total impervious 17,227 151461 -1,766 area (ft) Total pervious area 2,154 3,920 +1,766 (ft) Total pollutioin 12,102 11,124 -978 generating impervious area (ft) This information can be used to assess whether the existing on -site stormwater system (infiltration system) installed with the Walgreen development is adequate. The approved drainage report and as - built plans for the system that was installed with the Walgreens development is available at the City for your review. Once this evaluation is performed by the designer, it should be included in the drainage report for the Starbucks development and the stormwater design modified accordingly. This table has been included in the updated Stormwater Site Plan Report. Sheet C1.1— Cover Sheet and General Notes 4. Under utility purveyors please note Stormwater — City of Edmonds and Fire — Fire District 1. Noted. 5. Update General Notes to reflect 2014 WSDOT standards. Notes have been updated. Sheet C2.1— Temporary Erosion Control Plan 1. Please revise title of plan sheet to include "Demo". Title has been revised. 2. Replace detail E1.3 with the current version of the detail found on the City website. Detail E1.3 has been replaced with the current version. 250 4ch Ave S Edmonds, WA 98020 p.425.778,8500 f.425.778.5536 ENGINEERING Starbucks Edmonds January 15, 2015 Comment Response Page 3 of 5 3. The legend indicates "crushed surfacing" and on Sheet C3.1 several areas use a hatch type typical for concrete, which isn't shown in the legend. Please clarify where the crushed surfacing is to be used. Please revise legend to include "concrete surface". Legend has been corrected. Sheet C3.1— Grading, Drainage, and Paving Plan 1. Please review title of plan to include "Utilities". Title has been revised. 2. Clearly indicate utilities that are to be installed during this phase of the project. It appears as though a portion of the electrical system is in? Has the gas line been stubbed to the property? See items 3 and 4. 3. Please show power, phone, cable, etc. to the building. Power and data conduit added to plan. 4. The as -built plan shows an existing gas stub on the west side of the building. It appears to line up with the valve that has been indicated in the parking area. Service should be provided from this location instead of making another cut into Edmonds Way to bring service into the east side of the building. Plans have been revised to utilize existing gas stub. 5. Please label or add info in the legend on sheet C1.1 that indicates what the various symbols are on the plan sheet. Some appear to be valves or cleanouts or junction boxes?? These symbols are located on our survey base and are labeled only as "gate valve" with no additional information. We have updated the symbols to match our gate valve symbol. 6. One-way drive aisles shall be a minimum width of 12-feet. Please revise plans accordingly. Drive aisle widths will remain as shown per a 01/12/14 conversation with Jeanie McConnell. 7. Update reference to Type B curb ramp to state detail 6 instead of 7. Fixed. B. Sheet C2.1 indicates demolition of only two of the curb ramps along the west side of the parcel. However, this plan sheet indicates replacement of all three. Please revise plan sheets as needed. Plan revised to indicate demolition of all three curb ramps. 250 4'h Ave S Edmonds, WA 98020 p.425.778.8500 f.425.778.5536 ENGINEERING Starbucks Edmonds Comment Response January 15, 2015 Page 4 of 5 9. Show pavement striping and add callout for RPM's. Details for striping (including crosswalk) and RPM's should also be included in the civil plan set. Pavement striping already shown. There is already a callout for RPMs. Crosswalk detail no longer necessary per 01/09/14 email from Jeanie McConnell. 10. Please note open grate CB's shall have vane grates. Noted on CB schedule. 11. Please show any screening around the transformer that may be required through the design review process. See architectural set. 12. Add reference to which plan sheet the detail for the trash enclosure can be found. Reference added. Show trash enclosure pad as a concrete surface. Corrected. b. Drop pin sleeves shall be installed at both open and closed gate positions. Noted. See architectural drawings. 13. Clearly distinguish between sidewalk sections that are existing (installed with the Walgreens project) and those that are proposed to be installed with this project. Existing sidewalk shown on a faded layer. A match line has also been added to distinguish between new and existing sidewalk. 14. Sheet C4.1 indicates removal and replacement of a few sidewalk panels along the property frontage. Please indicate removal and replacement on this plan sheet. Updated to indicate removal of sidewalk panels. Sheet C4.1 Water and Sewer Plan 1. Provide 3 copies of this plan sheet with Olympic View Water & Sewer District signature of approval. Provided. Show sanitary side sewer connection, including i.e.'s. Sanitary sewer IE's added to sheet. 250 4`h Ave S Edmonds, WA 98020 p.425.778.8500 f.425.778.5536 ENGINEERING Starbucks Edmonds January 15, 2015 Comment Response Page S of 5 4c= 4M 250 4'h Ave S Edmonds, WA 98020 . .. . ...... --...C) . ......... — p.425.778.8500 f.425.778.5536 ENGINEERING