2015-0520 MGP Shell.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: June 26, 2015 TO: Glenn Goodman Merlone Geier Partners Email: ggoodman@merlonegeier.com FROM: Leif Bjorback, Building Official RE: Plan Check: BLD2015-0520 Project: MGP Shops Building Shell Project Address: 21940 Highway 99 During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses as to where the changes can be found on the plans, and submit revised plans/documents to a permit coordinator in the Development Services Department. Thank you. 1.Reference sheet A1.01, details 10 and 19: insulation Type 1 indicates batts in the exterior walls, yet the exterior wall details show rigid (R13), which agrees with the envelope worksheet/ energy calcs. Please coordinate. 2.Reference sheet A6.01: Change the glazing values in the General Notes to match those listed in energy code form ENV-SUM for compliance performance approach, which are 0.40 for SHGC and 0.53 for U-factor. 3.Reference sheet M0.1: Provide outside air calculations for Tenant spaces 1 and 4, using IMC Equation 4-1 and the OSA factors for restaurant use as listed in IMC Table 403.3. It appears the 300 CFM listed in the equipment schedule will fall significantly short of the minimum required for future restaurant use. 4.Provide calculations and details from a Washington state licensed engineer for seismic anchorage of rooftop mechanical units in excess of 400 lbs. 5.Please respond to the attached structural review comments from Beck and Associates. 6.Please complete and return the attached special inspection agreement forms. These may be returned any time prior to permit issuance.