Loading...
2015-0666 Freel (Oneill - Reed).pdfOV EQ_4 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: July 10, 2015 TO: Bruce O'Neill Design Works Construction mick@designworksconstruction.net FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2015-0666 Project: Freel Addition/Remodel Project Address: 18605 88th Avenue W. During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the 'clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. Sheet A2 I . Metal Connectors, Note 2 — the code reference is listed as IBC section R602.3 (1), but that code section is actually from the IRC. Please revise. 2. Plywood and Diaphragm, Note 1 — similarly, the IBC reference is actually an IRC reference. 3. Smoke/Carbon Monoxide Alarms, Note 2 — Please revise this language per IRC R314 as amended by the State of Washington. This section does not refer only to new construction, and battery operated smoke alarms are restricted. 4. Smoke/Carbon Monoxide Alarms, Note 4 — Please revise this language per IRC R315 as amended by the State of Washington. This section does not refer only to new construction. Sheet A3 5. Please show the locations of the smoke/carbon monoxide alarms on the plan set per IRC sections 314 and 315. 6. Please correct the references for the sections cut through the floor plan. In addition, provide all of the sections referenced or delete those deemed unnecessary. 7. Install the engineering lateral design into the floor plan. As of this review, there is no correlation between the shear wall schedule and the floor plan. If each of the walls accounted for in the lateral design are to be SW- 1, please indicate that on the floor plan by labeling each wall or with a note. In addition, designate which walls are shear walls with shading or hatching. 8. It appears that the whole house ventilation exhaust fan is proposed to be located within the laundry room. Please specify that the timer must be set to operate 2 hours, 45 minutes per each 4 hour period, 24 hours per day per IRC M1507. Sheet A5 9. The structural calculations show that the garage door header is to be a 4x 12 DF#2 or better. The plans show a 4x 10 DF#2. Please revise. 10. The beam over the garage is specified as a glue -laminated beam with a depth of 11.875 inches. Typically, glue -laminated beam depths are in multiples of 1.5 inches. Please clarify. 11. It appears that the rafter used to head off the perpendicular rafters at the rear right of the building is overstressed as shown. Please verify. 12. It appears that the floor beam calculations do not include all of the loads acting in the worst case. This calculation should include floor, wall and roof loads. Please verify. Page 2 of 2