20150702102827948.pdfTo: City of Edmonds — Chuck Miller — Plans Examiner
Re: Mietzner Brothers Plan Check BLD2015-0375 — 20607 85"' Place W
Review Reply Letter:
Comments from JoAnne Zulauf:
1. Deleted Proposed Rockeries
2. Removed silt plan
3. Updated impervious surface calcs to match Civils
4. Added note regarding utilities
5. Removed "Recorded Under"...
6. Removed sprinkler note
7. Surveyor calculates SF to be 23,302; County info may be wrong
8. Driveway is noted as Pervious concrete
9. Driveway at property line shown at 24'
Comments from Chuck Miller:
5/4/2015
1. Right South Elevation: Bedrm 3 window location adjusted -clouded on Al
2. Rear Elevation: Kitchen window location adjusted -clouded on A2
3. Foundation/Basement
a. Refer to structural engineer's Calc package
b. Bonus/rec window header re-calced-clouded on A3, new beam calc attached
c. Bonus/rec door header re-calced-clouded on A3, new beam talc attached
d. Bedrm 4 window header re-calced-clouded on A3, new beam calc attached
e. Footing in Bedrm 4 (actually 133) — widened to 24" -clouded on A3
f. Deck FJ span — span reduced 1' in all views -clouded on A3
g. Deck detail joist spacing corrected -clouded on A6
h. Garage footings under Girder truss — 3x3x10" re -enforced ftgs added — clouded on A3
i. Fnd Detail callouts added -clouded on A3
j. Thickened slab detail added and called out -clouded on A3
4. Refer to Structural engineering
5. First Floor
a. Carbon Monoxide call out (CM) added outside Office/Den-clouded on A4
b. Bathroom window indicated as SG -clouded on A4
c. Garage man door notes added -clouded on A4
d. Stair landing window SG note added -clouded on A4
e. Master Bath south window SG note added -clouded on A4
f. Master suite E window beam talc redone -clouded on A4 and beam calc attached
g. Great room E window beam talc redone -clouded on A4 and beam calc attached
h. Covered Outdoor Living beams calced- clouded on A4 and beam calc attached
6. Electrical Legend updated -clouded on A4
7. Refer to structural engineering
8. Stair detail
a. Wall fire stop note added -clouded on A6
b. Handrail note updated -clouded on A6
9. Refer to structural engineering
10. Specifications
a. Insulation note updated -clouded on A8
b. Freeze protection note updated -clouded on A8
c. Window sill exception 3 added -clouded on A8
d. Certificate WSEC 401.3 corrected -clouded on A8
11. Stairs
a. Stair code R311.7 updated -clouded on A8
b. Building Occupancy notes deleted from Specifications
c. Smoke Dectector R314.1 note updated -clouded on A8
Thank You
Doug Williams