Loading...
2015-0910 Classico SFR2- Hagge Design.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: November 19, 2015 TO: Classico Homes classicohomes@gmail.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2015-0910 Project: Classico SFR th Project Address: 532 7 Avenue S During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. nd Resubmittals must be made at the Development Services Department on the 2 Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. On sheet S5: 1.First Floor Shearwalls & Framing Above - Clarify the callout for beam ‘1-4’ – 5-1/4x11-7/8 PSL. It appears to be over spanned, fails in bending, and deflects beyond that permitted per Member 1-4 has been IRC Table 301.7. The response to the plan review comment states: revised to address loading. Please see the attached calculation.” The plans still indicate a 5-1/4x11-7/8 PSL instead of the 5-1/4x18 PSL noted in the resubmitted structural calculations