Loading...
2015-1010 Triece addition-remodel - Sandall Norrie Arch.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 17, 2015 TO: Peter Sandall pete@sandallnorrie.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2015-1010 Project: Triece addition-remodel th Project Address: 19405 89 Place W During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. General Review Notes: 1.The submitted construction documents appear to be prepared by an architectural firm. Provide on each page of the plans the stamp of a registered design professional. 2.Indicate on the plans the option to be selected to achieve the 0.5 minimum additional energy credits for additions less than 750 square feet per Washington Energy Code (WSEC) R406.2. On sheet A2: 1.Main Floor Plan a.Provide a ‘framing plan’ indicating the existing structural members over the ‘Main Floor’ per the City of Edmonds ‘Residential Addition/Remodel/Alteration Permit Submittal Requirements”. Of particular concern is the span and support of the existing floor joists where the ‘non load-bearing wall’ is to be removed on the north side of the ‘Dining Room’. b.Provide on the plans a detail, and a reference to it, for the minimum required construction to support the floor joists over the north end of the ‘Laundry’ where the indicated walls are to be removed. c.Provide on the plans a detail, and a reference to it, for the minimum required construction to support the floor joists over the south end of the ‘Dining Room’ where the indicated walls are to be removed and a door opening is added. d.Indicate on the plans the minimum required beam to support the loads over the window ‘marked’ ‘4’ in the south wall of the ‘Family Room’. e.Indicate on the plans the minimum required beams to support the loads over the door openings in the south wall of the ‘Dining Room’. f.Indicate on the plans the minimum required beam to support the loads over the window ‘marked’ ‘5’ in the south wall of the ‘Kitchen’. g.Indicate on the plans the required smoke alarm per International Residential Code (IRC) R314. h.Indicate on the plans the required carbon monoxide alarm per IRC R315. i.Indicate on the plans the minimum required local exhaust for the kitchen per IRC M1507.4. j.Indicate on the plans the minimum required local exhaust for the ‘1/2 bathroom’ per IRC M1507.4. On sheet A3: 2.Upper Floor Plan a.Indicate the plans the existing use of the spaces on the ‘Upper Floor’ per the City of Edmonds ‘Residential Addition/Remodel/Alteration Permit Submittal Requirements”. b.Indicate on the plans the required smoke alarms per International Residential Code (IRC) R314. c.Indicate on the plans the required carbon monoxide alarm per IRC R315. Page 2 of 2