2015-1019 Jantz addition-remodel - LaFon.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 6, 2015 TO: Warren LaFon warrenlafon@earthlink.net FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2015-1019 Project: Jantz addition-remodel Project Address: 547 Dayton Street During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. nd Resubmittals must be made at the Development Services Department on the 2 Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. General note: 1.Separate permits/submittals are required for the following: a.Fire Alarm b.Fire Sprinkler 2.Provide Washington State Energy Code (WSEC)/Northwest Energy Efficiency Council (NEEC) compliance forms for the following work: a.Building envelope b.Mechanical c.Lighting On sheet A-1.0: 3.General Notes a.Note #1 – Change the International Building Code (IBC) version from ‘2006’ to ‘2012’. b.Note #7 – Clarify the reference to IBC 717.4.3 Exception. That section cannot be found in the currently adopted code. c.Note #29 – Change the IBC Table reference from ‘508.3.3’ to ‘508.4’. d.Note #29 – Clarify the note “Per Table 508.3.3 (sic), there is no required separation between occupancy B & S-2 all areas of the building will be sprinklered.”. It does not appear to reflect the requirements of the applicable IBC Table 508.4 requirements found in the currently adopted code. 4.Project Data a.Occupancy – Change the occupancy classification from ‘Group S2 – Parking’ to ‘A- 3’ to reflect the proposed work to be completed under the currently issued permit BLD2014-0634. b.Construction Type – Change the number of stories from ‘2’ to ‘3’ to reflect that permitted per IBC 504.2 and proposed in the submitted construction documents. c.Occupant Load – Change the area of the ‘Main Floor’ to reflect the proposed work to be completed under the currently issued permit BLD2014-0634. d.Occupant Load – Change the calculated occupant load of the ‘Main Floor’ to reflect the proposed work to be completed under the currently issued permit BLD2014- 0634. e.Occupant Load – Indicate on the plans the occupant load of the ‘Third Floor’ proposed in the submitted construction documents. f.Occupant Load – Total Occupants – Indicate on the plans the re-calculated total incorporating the responses to review comments ‘4.d’ and ‘4.e’ above. g.IBC - Change the IBC version from ‘2006’ to ‘2012’. h.Codes - Change the referenced code versions from ‘2006’ to ‘2012’. i.Mech. Exhaust From Parking – Change the required minimum exhaust airflow ventilation rate to that of International Mechanical Code (IMC) Table 403.3 or eliminate the provided information to reflect the proposed work to be completed under the currently issued permit BLD2014-0634. On sheet A-2.1: 5.Detail 5 – Proposed Office Plan a.Indicate on the plans the required 1-hour fire-resistance rated (with exposure from both sides) exterior wall construction for the north and west walls per IBC Table 602. b.Clarify the indicated dimension ‘¾” (inches)’ at each end of the north exterior wall. ‘Plan Notes’ #1 states: “Do not scale drawings.” and the indicated wall length does appear to reflect the anticipated construction. c.Indicate on the plans the required means of egress illumination for the proposed office and the exit access stairway per IBC 1006.1. d.Provide a note on the plans indicating the required door hardware that has a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate per ICC A117.1-2009 section 404.2.6. On sheet A-2.2: 6.Detail 1 – Penthouse Floor & Exist. Roof Framing – Indicate on the plans the minimum required framing members to be used to construct the ‘double joist @ rim’ to guide proper installation and inspection. 7.Detail 2 – Penthouse Roof Framing Plan – Provide ‘stamped’ lateral calculations supporting the design of the proposed shear walls. Page 2 of 2