20151102124243.pdfPLAN REVIEW COMMENTS BUILDING DIVISION /"Z, b Y'V) (425) 771-0220 R E i I of ' 1" 2 7 ' ' �� (���.,1;� SII., � � �������l�ll ���',�� DATE: October 25, 2015 TO: U°ww V,� I111KUmuHmw 1, FROM: ilru e 0`'14efli RE: Plan Check: BLD2015-1155 Project: Jenkins addition -remodel Project Address: 16902 Talbot Road During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the `clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2"a Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. On sheet A-3: 1. Glazing Schedule - Clarify the difference in the width of the window marked `9' and of that represented on the `Main Floor Plan' and the `Roof Framing Plan' on sheet `A-5'. (F.,(isd.ung 2. Main Floor Plan a. Indicate on the plans the required safety glazing for the windows `marked' `2' and `3' adjacent the door in the `New Entry' per International Residential Code (IRC) R308.4.2. � ��r tempered gktss note ad(:61 to :jllLAZII',' G SC11EI)UiID fF) b. Indicate on the plans the required minimum 100 CFM intermittent local exhaust for the `Kitchen' per IRC M1507.4. c. Indicate on the plans the required carbon monoxide alarm outside of and in the immediate vicinity of the `Master Bedroom' per IRC R315 (CO is shown maw ide imustcm bedroom, piw-vii to sea, hae adde(:p wio4e to d. Clarify the difference in the dimensions given for the following rooms and of those indicated on the `Main Floor As Built': `Library' (was `Den') `Master Bedroom' `Living Room' Indications of wall changes or additions in those areas could not be found on the plans. (1 aoo :cn dimensions clarified on plans for 'IJ brary/D ,urn_', 'Master bedroom.', anal J,ivimn8 R.00iran'. Notes adda,;d to Ma.irm floor AS 131AI "i"8 to chirify walls to be removed "W`1"1:31.") e. Clarify the difference in the dimensions given for the `Existing Deck' west of the `Great Room' and of that indicated on the `Main Floor As Built'. A note states: "Existing deck to be rebuilt (same foot print)", although an addition to it appears to have been made at the north end. (t. arifi.cation. added to mote "except or 18" added to nnor(h end. of deck".) On sheet A-4: 3. Lower Floor Plan a. Indicate on the plans the required carbon monoxide alarm outside of and in the immediate vicinity of `Bedroom 2' and `Bedroom 3' per IRC R315. (CO is shown owsid e bedroom d and bed:lawdao n°n 3, hard to see have added note to clarify.) b. Indicate on the plans the required safety glazing for the window `marked' ` 18A' at the stair landing in the `Garage' per International Residential Code (IRC) R308.4.7. (f..3" t.erni,)ered glass note added to t LAZINCI Sly"131:,1ifULE) c. Indicate on the plans the required safety glazing for the window `marked' `1813' adjacent the stairs in the `Garage' per International Residential Code (IRC) R308.4.6. ('T" ternipered glass mote added to (IM b DYG SCI IEDIii,ii) d. Clarify the difference in the dimensions given for the `Rec Room' and of that given for the south -most `Family' room indicated on the `Lower Floor As Built'. Indications of wall changes or additions in that area could not be found on the plans. t `i ,,dadaiiY roornn dins a'.dn io ns on #[..i",sNv ^°a incorrect as the (:onalaaite, . proitrair: i ncladed hail in over ai l width d3imc:isionn. This dimension has been. corrected, Nit stlii slight discrepancy becrtaiise nail aicnmg vnest, vide of stair is, being removed tIkus m ald rig tiaa. room overall dii n ensio n larg, er.) On sheet A-5: 4. Roof Framing Plan a. Indicate on the plans the required minimum beam to be used to support the loads over the added window `marked' elsewhere as '13' in the west wall of the `Living Room'. There does not appear to be a window indicated at that location on sheet `A3' — Main Floor As Built. ilHnmror in :Malan floor A,13 11131 l ll_.,'l , there iv an ex 5'0" irndow at '13' in Ilf.,ivving room witin existing 4x 10 l:ma ad tn,.) b. Indicate on the plans the required minimum beam to be used to support the loads over the sliding glass door `marked' elsewhere as '15' in the west wall of the `Master Bedroom'. It appears to be larger than the doors indicated at that location on sheet `A-3' — Main Floor As Built. (F rror in Main Wloor AS II31JIL W , there as ra a existing 9'0" 3 panel (loot, in Master pruw,aproom at '15' araptlru exi ding 4y] 0 header) c. Indicate on the plans the required minimum beam to be used to support the loads over the window `marked' elsewhere as `18' in the east wall of the `Library'. It appears to be larger than the window indicated at that location on sheet `A-3' — Main Floor As Built. Minin~warun lau-,ani required above win.dovv 18' (7"0"') is 4,xg as, sliaava�n on fi unijnp; p laan ( d. Indicate on the plans the required minimum beam to be used to support the loads over the added door `marked' elsewhere as `B' in the east wall of the `Pantry/Mud' room. There does not appear to be a door indicated at that location on sheet `A-3' — Main Floor As Built. (Mpninian n haa,nin mreapuui red a.l ove new (loot, `Illi' (3'0") is 4N 8 as sf.aaa as on fraaniing japan) e. Indicate on the plans the required minimum beam to be used to support the loads over the added door `marked' elsewhere as `C', and over the added window `marked' elsewhere as 'I 7A', in the south wall of the `Garage. There does not appear to be a door or window indicated at those locations on sheet `A-3' — Main Floor As Built. (Error in Mj, 11p JWLT, there is an a,y isf:iRig door in 1:he saa�..utpa anaa l of l�lu�.aa .p :��; (aa,�r p�aiaaap.am(. / p ppWaaua.a;lsra�. MpnWuriaa:ina JulAderrecp.dred over winap.ow `l 7' ' i!s as 4 l lig l ll r /�1:2 �r �,�liown aan frariimaap,:; plan,( 5. Main Floor Framing Plan - Indicate on the plans the required minimum beam to be used to support the loads over the added windows `marked' elsewhere as `24', `24A', and `25' in the respective south walls of `Tim's Office', `Christi's Office', and the `Media' room. There does not appear to be windows indicated at those locations on sheet `A-4' — Lower Floor As Built. (l ;rror in AS BUILT, there are existing vaindo r ((),,vindow and 25, see photos. l/pna;10 w 24 umediia: ed in size Warm 8'0"1,o6'0". `°in(lo",1 24 uaa:lalamci t,o'.Chrisf,i'sa Ofl,'ia <;'(4'0") lan:aale r :re(lp iiarar(i 4 x l O 111 uu 2,) Page 2 of 3 On sheet A-6: 6. South Elevation — Clarify the difference in the locations of the windows `marked' elsewhere as `24' and `24A', and of the size of the window `marked' `24A', and of that represented on sheet `A-4' — Lower Floor Plan- and on sheet `A-5' — Main Floor Framing Plan. (Window l.ocaap;iaans clarifi.c on "South l Wa nation All to cloarrespon to I`Waaaar plans.) ans.) On sheet A-8: 7. Detail 6 — Brace To Beam Conn. — Change on the plans the number of the detail from `6' to `4' to reflect that applicable to the anticipated construction where referenced on sheet `A-8' — Deck Structure Plan. (Detail it maarleer on plan a: h aaf,,,,e l from 6 to 4 ) 8. Deck Structure Plan — Change on the plans the detail reference from `2/A8' to 'I /A8' to reflect that applicable to the anticipated construction where referenced. (2/..8 on rraau.ith. end aai`chaann l ()u%Wra,11 c[ia ged to i AR)