20151110085603.pdfCLA
Y USIGNfG
A0' 'f fMCWM4 QES ci�l S RICES.
�li'� WA 2QfF���P:0�9�1
C�AY�7,�'S�'"+�r"lY,LLCCOM
Nov. 2, 2015
BUILDING DTVI TON CORRECTION RESPONSE LETTER, 2:
Protect #- 81 D201 -1091
Proied Address:
19715 80th Place W.
Edmonds, WA
Owner: Tom Albertson
Plans Examiner. Chuck Miller
Here are notes addressing corrections, clarifications, or changes for this project.
NOV 0 3 2015
Shegt_A100 - No
Corrections:
1. "Door/Win. Schedule. Clarify the difference between the size of the windows marked A'and
'S "and of those represented and marked on sheet A102'- New Floor Plan... "
Response:
Door and window schedule has been updated on p. A100 to properly cross-reference New Floor
Plan on p. A102.
Sheet A101. - Exq. Fluor Plan;
Corrections:
2. "Detail 2 - New Roof Plan - Ventilation - Clarify the reference to the 'FHA 1/150 rule'
regarding the required roof ventilation. Verify that the proposed values meet the minimum
required per IRC R806.2. "
Response:
Ventilation requirements are updated on p. A101 to meet the minimum required per IRC R806.2
Sheel A102 - Neyy Floor Plan -
Corrections:
3. Detail 3 - Level 1- New
"J. Indicate on the plans the required SWI shearwalls along shear wall line '142'proposed in the
provided structural calculations. An approximately 4'section of 'existing' wall has been 'marked'
'SWI -and another 5.5'section of exg. wall has been 'marked' 'SW3 : Together they appear to
provide a bit less than one-half of the required lateral resistance of that noted in the provided
structural calculations. "
Response:
Shearwall designations have been updated on the plans and structural calculations.
CLAY DESIGN, LLC is a full service architectural design company.
We provide quality architectural and interior design services.
Corrections:
"b. Provide on the plans a detail, and a reference to it, for the minimum required attachment at
the top of the interior shear walls marked 'SW3' and 'SWI ' along shear wall line 142-1. "
Response:
Shearwall connection details for SW1 and SW3 have been added to p. A109.
Corrections:
"c. Provide on the plans a detail, and a reference to it, for installation criteria of the indicated
'LSTA24'straps at the ends of the interior shear walls marked 'SW3'and 'SWI'along shear wall
line 142-1. "
Response:
The shear wall is being taken all the way up to the roof structure, so the LSTA24 straps are no
longer required, and the reference has been removed from the drawings.
NbOt 03 — Edn lir rain ;
Corrections:
4. "Foundation Plan and Floor Framing Plan — Clarify reference to detail 'D61AIO8'for the ledger
connection... "
Response:
Ledger connection has been updated in detail D6, p. A108 — using 1/2" through bolts.
h 104 -.. Framing Plans:
Corrections:
5. "a. Clarify the callout for the proposed 2x8 rafters. At the maximum span they appear to be
over spanned and fail in bending....
Res onset
Common and jack rafters have been updated to 2x10 rafters on p. A104.
Corrections:
"b. Clarify the callout for 2-2x10 hip rafters. They appear to be over spanned, fail in bending,
deflect beyond that permitted per IRC Table R3O1.7... the spedried 'Simpson MTHMQ-2' hanger
proposed is not designed for a connection into the end grain of a wood framing member. "
Response:
The 2-2x10 hip rafters have been updated to 2-2x12 rafters. Also, the hanger has been
changed to'Simpson HHRC44'.
Corrections:
"c. Clarify the callout for the proposed 2-2x10 ridge beam. It appears to be over spanned, fails
in bending, and deflects beyond that permitted per IRC Table R3O1.7"
Res:
The ridge beam has been updated to 2-2x12 beam.
CLAY DESIGN, LLC is a full service architectural design company.
We provide quality architectural and interior design services.
Sheet A106 — Sections:
Corrections:
6. "Detail 2 — Transverse Section — Clarify callout for detail 'DIIIAI09'for the required
construction at the top of the exterior wall. The referenced detail does not appear to
correspond' with that anticipated at the top of the wall. "
Response:
Detail 2 was updated with the proper callout designation for the detail referencing the condition
at the top of the wall.
Please let me know if you have any questions to the responses that have been provided.
Thanks,
Elizabeth Clay (Johnson)
Clay Design, LLC
elizabetLiCcbc6aycj snlI .corn
206.660.0890
CLAY DESIGN, LLC is a full service architectural design company..
We provide quality architectural and interior design services.