20151116124502.pdfTS '�Wwt�/�� ?°."� � P JoAnne Zulaufi 121 5th Avenue North NO Edmonds, WA 98020 (425) 771-0220 (� l -I�, (� I '1 g, 0 I �� BUR, �m ,,G� T � �F n UNIh.N" Re: Hyde Park — Plan Check # BLD20150117/78/79 IECO No. 14-0659 Dear Ms. Zulauf, The project referenced above is revised in response to the review comments dated October 21st, 2015. The review comments are numbered on the letter and have been addressed in italics as follows: Sheet A1.0 —Site Plan: 4. 10/20115 Not Done. Existin'i Existingwater rieter also needs clearance. 8/5/15 Not Done. The water meter location is no longer the same as the civils. Water meters must be located in the right of way against the front property line. Please relocate meteres on plan. Water meters need a minimum clearance of 3 feet from other structures. To save some area, an option is to install 2 — 2" meters then use private meters within the property. Existing water meter meet the clearance requirements, see its location on A1.0. Revsions of the locations of the proposed water meters has been made to match as civils. Water meters have a min. clearance of 3 feet from all other structures, see water meters locations on sheet A].0 5. Ok. 6. Ok. 7. Ok. 8. 10/20115 Not Done. 8/5/15 Unclear. Please remove all clouding from site plan. Add the width where it can be read easily. Call out width of access road at property line. The clouding has been removed from site plans. Width has been called out at where it can be read easily. 9. Ok. 10. Ok. 11. 10/20/15 Not Done. The wall is not in the same location or the carne material as the civils. Calll out the length, show the wall in the sarne location a a wall withIT rNr t6 t ITIT 9 r r d c ITl ��d i tf m wall elevations at each end. 8/15115 Not done. Location and amount of block walls and fences do not appear to be consistent between site plan, landscape plans, and civil plans. Please revise as needed. Revision made. The wall is matching in the same location and the same material as the civils. Length of the wall has been called out. Top and bottom wall elevations at each end have been provided. See sheet A1.0 12. Ok 13. 10/20115 Not Done. -8/5/15 Not done. The impervious surface numbers do not match the civils. The impervious surface total breakdown does not agree with the total on the copied classification sheet and the stormwater report. Please recalculate and revise the plans as necessary. DATE FAXED/E-MAILED 11/6/2015 PAGE 1 OF 2 Revision made. The impervious surface total breakdown is matching with the total on the copied classification sheet and the stormwater 14. Ok. Please feel free to contact me with any questions or comments you may have. Sincerely, Larry Ho DATE FAXED/E-MAILED 11/6/2015 PAGE 2 OF 2 IIF�w ��, Ilf m��Mw y'NIA+iA NQV 0 9 2015 INSIGHT ENGINEERING CO, Y _ .............n........... �������. October 30, 2015 JoAnne Zulauf 121 5th Avenue North Edmonds, WA 98020 (425) 771-0220 Re: Hyde Park — Plan Check # BLD20150117/78/79 IECO No. 14-0659 Dear Ms. Zulauf, The project referenced above is revised in response to the review comments dated October 21, 2015. The review comments are numbered on the letter and have been addressed in italics as follows: General: 1. 10/20/15 Not Done. 8/5/15 Not Received. The King County Site Improvement Worksheet can be located on the King County website under "forms". The City prefers the use of this form for bond information. Thank you for providing an itemized cost estimate with your Stormwater Site Plan. Please revise cost estimate to include all on- site and off-site improvements. Anything you are unable to find in the worksheet please add to the write-in area on page 8 of 9. This estimate should include all utilities, the storm system vault and other civil improvements. The bond will be 120% of the cost of the right of way improvements, tesc measures, and the on site stormwater system. Inspection fees will be 3.3% of the total costs of all the improvements on the site and in the right of way. The bond quantities have been updated and included with this submittal. 2. Done 3. Done Sheet ALO Site Plan 14. See architectural plans for reply Sheet CLO Cover Sheet 15. Done 16. 10/20/15 Not Done see #11 above. 8/5/15 Not done. Walls are still shown along west property line on civils and not on site plan A1.0. Remove from plan or add reference to structural engineering. Location and amount of block walls and fences do not appear to be consistent between site plan, landscape plan, and civil plans. Please revise as needed. Refer to revised plan set. The architectural and civil engineering sit plans have been coordinated. 17. Done 18. Done 19. Done 20. Done Sheet CIA Existing Features a 20a. OK Sheet C2.0 Grading and T ESC Plan 21. Done 22. Done 23. Done 24. Done Sheet C3.0 Road. Drainage and Utility Plan Water: 25. 10/20/15 Not Done. Confirm by providing a detail that the monument sign footings will not project into the right of way. There are still only 10 water meters. 8/5/15 Not Done. Please review the details included in your plans for the Water Meter, box size is listed, the 6 -foot fence, and the Monument Sign. Meter box and the fence and sign footings can not fit in this space. This plans show 10 water services and 1 irrigation (existing). There are 12 units. Please revise plans to reflect actual proposed construction. Water meters must be located in the right of way against the front property line. Please relocate meters on plan. Water meters need at minimum clearance of 3 feet from other structures, but not between them. An option to save PO Box 1478 • Everett, WA 98206 • Phone: (425) 303-9363 Fax: (425) 303-9362 • Emaii:info@insightengineering.net =--1°ee11 wwwa---.�.. ... ... .... some space may be to install 2 — 2" meters and then provide private meters within the property. Blow off valve can be removed. Please see the revised landscape plan for the location and dimensions of the monument sign. The locations of the water meters and fire hydrant have been revised per your suggestion. Please refer to the revised plan set. 26. 10/20/15 Not Done. 8/5/15 Not Done. Please review the Fire Hydrant detail and the Monument sign detail. The hydrant cannot fit in the proposed location. The original comment points out that a minimum clearance is 3ft. Revise plans to reflect actual proposed construction. I have consulted with the Fire Marshall and there is no variance allowed regarding the 3 ft clearance around the hydrant. As discussed in previous meetings, the hydrant can be located off the water main running perpendicular to 212th on the adjacent property. A hydrant can be installed there in the right of way and still meet the spacing required by the Fire Marshall. Attached map showing location. Fire h drants are required to have a minimum of 3ft surrounding clearance. If you are unable to make the 3ft clearance, please contact the fire marshall, John Westfall, to discuss options. The location of the fire hydrant has been revised. The fire hydrant is at least 3 feet from all structures. Please refer to the revised plan set. 27. Done 28. Done 29. Done 30. Done 31. Done Sewer: 32. Done 33. Done 34. Done 35.a. 10/20/15 Not Done The revised design does not meet the DOE criteria under section C1-6.1 and C1-4.1. Please review all requirements in C1 before submitting a new design. Cleanouts should be labeled with invert elevations. 8/5/15 NEW COMMENT The City's Sewer Division has identified that the proposed sewer line within the access road exceeds 150' in length (scales at 160'), length callout on plans is under another callout. Per DOE's Criteria for Sewage Works Design section CI -6.1, a clean out may be used at the end of a run only if it is under 150' in length. So two options to address this would be: 1) replace CO #4 with a manhole and add a type 2 manhole standard detail to plans, or 2) shorten the main line to under 150' and lengthen the connection after CO #4 to Building #3. PO Box 1478 • Everett, WA 98206 • Phone: (425) 303-9363 Fax: (425) 303-9362 • Email:info@insightengineering.net A manhole has been added to the end of the line and the cleanout inverts have been labeled. Storm: ',onarnents fi-orrr the City Storm water Dwneer attached. 35. 10/20/15 Not done. The civils still do not match the site plan.A1.0. 8/5/15 Not done. The civils still do not match the site plan.A1.0. The impervious surface total breakdown does not agree with the total on the copied site plan. Please recalculate and revise the plans and report if necessary. Please refer to the revised plan set. The civil and architect have gotten together to get one cohesive plan set. 36. Done 37. Done 38. Done 39. Done 40. Done 41. Done 42a. Done 42b. Done 43..10/20/15 Not .Done See #11 The architectural and civil plans have been coordinated. 44. Done 45. 10/20/15 Not Done 8/5/15 Not done. Other conflicts as well, see Water comments above. Signs shall be set back from sidewalk and shall not interfere with vehicle site distance. Please provide a sign detail. No details were found in the architectural or structurals. Please see the revised landscape plans for the sign detail and for the site distance detail. The water line has been changed as well. See revised civil drawings for revised utility detail. PO Box 1478 • Everett, WA 98206 • Phone: (425) 303-9363 Fax: (425) 303-9362 • Email:info@insightengineering.net ..........._......_.. 46. Done Sheet C3.1 Road, Drainage and Utilitv Plan 47. Done 48. Done New comirnents t e ardin -, 6/18/1 submittal: SheetC12 1 r� �jtgge (jj)pic venwnts Ng,511eet Submitted 6/18/15 Sheet C4.1 General Notes and Details 57. Ok 10/20/15 Location of mailbox , water meter etc are not shown consistently with the civils. The landscape, architectural and civil plans have been revised to coordinate the location of the above referenced items with each other.. 10/20/15 Stormwater Engineer Comments:. Storinw ter Site Plan, dated September June 2' 2015 Pap -e 8, MR46 — The plan should state the amount of pollution generating impervious surface area created by the project. If it is 5,000 square feet or greater, water quality treatment is required. Partially resolved. The site proposes 7,365 SF of PGIS. The text states that treatment will be provided by infiltrating through pervious pavers, stone, and subsequent soil. The site is located in the Hall Creek/Lake Ballinger basin. Phosphorus is a pollutant of concern. For flow control other than infiltration, all sites in this basin need phosphorus control. For site that use infiltration for flow control, they are exempt from phosphorus control if they are more than'/4 mile from the Creek or Lake. This is the case here, but other treatment is required. According to Section 6.3.2, page 174 of the following document: httn://www.DsD.wa.aov/downloads/LID/20121221 L IDinanual FINAL secure_ndf, , no water quality treatment credit is given by Ecology associated with stormwater passing PO Box 1478 • Everett, WA 98206 • Phone: (425) 303-9363 Fax: (425) 303-9362 • Email:info@insightengineering.net through a permeable pavement system. Treatment can be attained by one of the following: 1) Infiltrate 91 % of the annual stormwater runoff file into subgrade soils that have a cation exchange capacity of greater than or equal to 5 milliequivalents/100 grams of dry soil and a minimum organic content of 0.5 percent. The soil must have these characteristics for a minimum depth of 18 inches. Or 2) Design a treatment layer into the aggregate base that has the characteristics described in 1) for subgrade soil. The applicant refers to a letter from the geotechnical engineer(dated August 25th, 2015) recommending a topsoil layer with sufficient cation exchange capacity to treat infiltrated runoff. This is feasible, however, the special inspections necessary to ensure this is done properly are not described and need to be included in the development permit. The plans have been modified to include such notes. Please see the revised detail VC3.0 Page 8�7 — The location of the R -tank infiltration system does not match up to a location of the geotechnical investigations. Due to the variability of subsurface soils, investigations need to at the same horizontal and vertical location as the proposed system. If a test pit in the location of the proposed R -tank system shows the same subsurface strata as locations IT -1 and IT -2, the 2.5 inches per hour design infiltration rate will be accepted. Not resolved. The response says "The geotechnical Engineer will perform a (sic) infiltration test at the proposed location of the R -tank system." No addition geotechnical test was found in this submittal. Testing must be performed and the results incorporated into the design prior to any potential approval of the permit application. A geotechnical engineer has visited the site and a letter of his results, of further testing, is included with this submittal. The soil type under the r -tank is the same as other areas of the site. r Page 1.8 —Resolved o Pj-v ge 22 — Resolved Plans Dated January 29. 2015 — (These comments were not formally addressed in the Comment -Response letter lxom IECO dated 6//2015, but appear to be partially addressed in the most recent plan submittal.) a Sheet C3.0 —Resolved; + Sheet, C3,0 C:)�,� 'tail 1. Resolved. * Sheet C3.1 - Resolved. w 10/20 Addition.al information ro_;;ided by the citya�w1aineer reaardintp Lyd. Force Trunk Line: The asbuilts of the trunk line were obtained and the actual location of the trunk line is shown on the plans. The depth of the trunk line in the vicinity of our sewer crossing has been shown on the profile and a note has been added for the contractor to verb the location and depth, prior to construction. PO Box 1478 + Everett, WA 98206 + Phone: (425) 303-9363 Fax: (425) 303-9362 + Email:info@insightengineering.net Please feel free to contact me with any questions or comments you may have. Sincerely, Brian Kalab, P.E. PO Box 1478 # Everett, WA 98206 • Phone: (425) 303-9363 Fax: (425) 303-9362 • Email:info@insightengineering.net _....... integrated site design 12743 26th Ave NE Seattle, WA 98125 P: 206.363.9049 www.i-s-d.com 1N(W 0 9 201"i ti-,OJIIIILDUNG Dlk=V'" RI`Ci EIV crre cjr Il.EbihioiiMNh.x, Attn: Larry Ho Prime Consultant/ Owners Representative Re: City of Edmonds Correction Letter Response Third Review Plan Check # BLD20150177/78/79 Hyde Hyde Park MF 7232, 7234,7238 212th St. SW Reviewer: JoAnne Zulauf Date: 10.30.2015 Mr. Ho, The following is a response to the recently issued correction letter from JoAnne Zulauf, City of Edmonds Engineering Department, dated October 21 st, 2015. I have included both the correction and our response to all landscape and landscape related issues as follows: 25. Correction Sheet C3.0 Road Drainage and Utility Plan - Water: 10/20/15 Correction Request: Not Done Confirm by providing a detail that the monument sign footings will not project into the right of way. Response: ISD: has provided a detail of the monument sign with footings on Sheet L-1 Detail #2 and 3. The wall and footings are indicated as being entirely within the subject property. 57. Correction Sheet L 1..0 Landscape Plan The location of the mailbox, water meter etc. are not shown consistently with Civil's. Response: ISD: has coordinated the locations of the mailbox and water meters with the Civil Engineer and has revised sheets L 1.0 and L2.0 to reflect the correct location and configuration of these elements. Additionally, plant list has been revised to reflect changes in plants as required to accommodate the meter and mailbox paving revisions. Please let me know if there are any other landscape related issues that need our attention. Sincerely, Ray Robinson, RLA/ASLA