2015-1493 Thwing 3rd Review.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: March 29, 2016 TO: Andrew Thwing andrewthwing@hotmail.com FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2015-1493 – 3rd Review Project: Sun Room Renovation rd Project Address: 19804 83 Place W. After a 3rd review of the plans by the Building Division for the above noted project, it has been determined that the plans still do not meet the minimum Code requirements, and therefore a complete review cannot be performed. Please consider hiring a design professional (architect, designer, etc.) to assist you in producing the construction documents necessary to facilitate a proper review and to help guide proper inspection. The following items supersede any previous correction notices, and must be clarified before approval of this project can be granted: 1.The 2x10 ridge board is shown to be bearing on an existing 6x8 header. Please provide calculations showing that the existing 6x8 is structurally adequate to support the new point load from the ridge board. From the information given, it appears that header may be overstressed. 2.Please verify how the point load at the interior end of the ridge beam will be supported. As shown, it is located between to trusses. 3.Please provide a floor plan that shows each window and door as shown on the elevation views. 4.It is shown on the plans that the walls will be constructed of 2x4. It is also expressed that R- 21 is required in the walls. It is required that the method of achieving R-21 in the walls is explicitly specified to avoid confusion or unforeseen expense during construction. 5.Similarly, it is shown on the plans that the roof rafters are to be 2x10 with R-38 required. It is required that the method of achieving R-38 in the roof is explicitly specified to avoid confusion or unforeseen expense during construction. 6.It appears that the configuration of viable shear resisting elements does not conform to any prescriptive method of wall design per IRC Chapter 6. Please clarify the method of compliance by specifying the braced wall design method, or provide lateral calculations stamped by a design professional licensed in the State of Washington to verify the design as shown. 7.Per the Washington State Energy Code (WSEC) Table 402.1.1, slab on grade floors within heated spaces require R-10 for 2 feet around the perimeter or 2 feet deep around the perimeter. Please show how this requirement will be met on the plans. 8.It is shown on the plan that the required 0.5 Energy Credit required in WSEC section 406 is to be achieved using Table 406.2, Option 5a. To claim that credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. Page 2 of 2