2015-1591 Beauty Salon TI - LOT Design.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: January 13, 2016 TO: Golden T Construction lthrondsen@msn.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2015-1591 th Project Address: 10014 238 Street SW Project: Beauty Salon TI Scope: Construct beauty salon – B occupancy – 1337 sq. ft. gross area – 13 occupants - V-B construction – NFPA sprinkler system not required – mechanical and plumbing included disapproved Please be advised that the building plans for the above referenced project have been for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following . information, clarifications, or changes are neededReviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. nd Resubmittals must be made at the Development Services Department on the 2 Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. On the City of Edmonds ‘Commercial & Multi-Family Building Permit Application’ – Form E 1.Mechanical – Clarify the difference in the indicated new and relocated appliances/systems to be installed and of that represented on the plans and required per the International Mechanical Code (IMC). 2.Plumbing - Clarify the difference in the indicated new and relocated fixtures to be installed and of that represented on the plans and required per the Uniform Plumbing Code (UPC). On the Washington State Energy Code Commercial Provisions – Lighting Compliance Forms 3.Provide as part of a complete submittal Washington State Energy Code (WSEC) Lighting Compliance Forms reflecting the requirements of the currently adopted 2012 code. On sheet CS 1 – General Notes, Project Information, ADA Restroom Requirements 4.Project Information a.Indicate on the plans the occupancy classification(s) of the proposed use per International Building Code (IBC) 302.1 and the City of Edmonds ‘Tenant Improvement Permit Submittal Requirements’. b.Indicate on the plans the total square footage of the proposed use(s) per the City of Edmonds ‘Tenant Improvement Permit Submittal Requirements’. c.Indicate on the plans the construction classification(s) of the building per IBC 602.1 and the City of Edmonds ‘Tenant Improvement Permit Submittal Requirements’. d.Indicate on the plans the occupant load(s) of the proposed use(s) and area(s) per IBC Table 1004.1.2 and the City of Edmonds ‘Tenant Improvement Permit Submittal Requirements’. 5.General Notes a.Energy Code – Change the referenced code and table to that applicable to commercial buildings per WSEC C101. b.Section 1203 – Ventilation – Change the following referenced code sections to that adopted by the State Building Code Council/Washington State Legislature per Chapter 51-50 Washington Administrative Code (WAC): 1203.1 General · 1203.4 Natural ventilation · 1204.1 Equipment and systems · On sheet CS 2 – Site Plan, Aerial Site View, Vicinity Map, Project Information 6.Site Plan - Clarify on the plans the indicated width of the accessible parking space. It does not appear to meet the requirement for van parking spaces per IBC 1106.5/ICC A117.1-2009 502.2. On sheet A-4 – Proposed Floor Plan 7.Proposed Floor Framing Plan a.Clarify the notes “(4) BARBARA STATIONS” to guide proper review of the proposed work. b.Indicate on the plans the required door hardware that has a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate per IBC 1008.1.9.2/ICC A117.1-2009 404.2.6. On sheet A-5 – Ceiling Framing Plan 8.Ceiling Framing Plan a.Clarify the proposed installation of ‘diagonal uprights @ 4’-0” o/c’. With the 2x6 rafters spaced 24” on-center as specified on sheet ‘A-7’ – Building Section – those without the ‘diagonal uprights’ appear to be over spanned, fail in bending, and deflect beyond that allowable per IBC Table 1604.3. b.Clarify the proposed installation of 2x6 HF #2 ceiling joists at 16” on-center. It does not appear to result in the roof framing construction per IBC 2308.10.4. Page 2 of 3 On sheet A-6 – Equipment Lay-Out Plan, Accessible Ramp & Parking Lay-Out 9.Proposed Equipment-Accessible Ramp & Accessible Parking Lay-Out a.Indicate on the plans the proposed shelving/racks (including height(s)) to be installed in the ‘Storage’ areas per the City of Edmonds ‘Tenant Improvement Permit Submittal Requirements’. b.Provide ‘cut-sheets’ for the proposed plumbing fixtures to be installed. Of particular concern for use in a beauty shop is the required backflow prevention for faucets and fixture fittings with hose connected outlets per UPC 417.4 and the maintenance of the plumbing fixture traps per UPC 1003/1004. c.Indicate on the plans the required accessible service counter or portion of the counter per IBC 1103/ICC A117.1-2009 section 904. d.Clarify on the plans the indicated width of the accessible parking space. It does not appear to meet the requirement for van parking spaces per IBC 1106.5/ICC A117.1- 2009 502.2. On sheet A-7 – Building Sections 10.Building Section – Clarify the difference in the proposed wall insulation to be installed and of that required per WSEC Table C402.2. On sheet E-1 – Elevations 11.Lighting Floor Framing Plan – Indicate on the plans the proposed method of providing the required minimum ventilation rates for the proposed use per IMC Table 403.3. Page 3 of 3