2016-0018 Select Homes SFR2 - Nash.pdf
City of Edmonds
j
PLAN REVIEW COMMENTS
BUILDING DIVISION
(425) 771-0220
DATE: March 17, 2016
TO: Select Homes, Inc.
kayla.clark@outlook.com
FROM: Chuck Miller, Plans Examiner
RE: Plan Check: BLD2016-0018
th
Project Address: 21719 88 Avenue W
Project: Select Homes SFR
Scope: Construct single family residence R-3/U occupancy group V-B
construction - NFPA-13D sprinkler system required mechanical and plumbing
included
disapproved
Please be advised that the building plans for the above referenced project have been
for the purposes of obtaining a building permit. During a review of the plans by the Building
Division for compliance with the applicable building codes, it was found that the following
.
information, clarifications, or changes are neededReviews by other divisions, such as Planning,
Engineering, or Fire, may result in additional comments that require attention beyond the scope of
this letter.
A complete review cannot be performed until the revised plans/documents, including a
written response in itemized letter formatindicating where the clouded or otherwise
highlighted changes can be found on the revised plans, have been submitted to a Permit
Coordinator.
nd
Resubmittals must be made at the Development Services Department on the 2
Floor of City
Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on
Wednesdays.
On sheet A3 - Foundation Plan
1.Clarify the callout for the anchorage to be used for the HD7B holdowns at each end of the
P2-4 shear walls along the west wall of the Bonus Room. The SSTB28 anchor bolts
have very specific installation requirements that do not appear capable of being met by the
proposed construction. The 4 foot wide stem wall would not allow the required minimum
49-3/4 long (2 x l) horizontal rebar, located 5 from the ends/corners of the stemwall, to be
e
installed.
2.Identify on the plans the element represented by the dashed-line rectangle surrounding the
area noted in the above plan review comment to guide proper review, construction, and
inspection. It may be a cloud identifying a change on the plans in response to an earlier
review comment, but could also be interpreted as a large footing or other construction.