20160302145822.pdfFebruary 29,2016 To: Chuck Miller, Plans Examiner Building Division, Development Services City of Edmonds, WA 425-771-0220 From: Eddie King Edking 11 @hotmail.com Project: Red Lantern Chinese Restaurant Permit: BLD2016-0088 Project Address: 546 5t" Avenue S, Edmonds, WA 98020 Dear Mr. Miller, Thank you for your comments and please see the following responses for corrections. On sheet Al — Site Plan -Floor Plan -RCP Plan-Section/ADA Detail: 1. Scope of Work — Clarify the indicated addition of a 'Bar' as part of the proposed work under this permit. There does not appear to be a corresponding area represented on detail '5'— Proposed New Door Schedule (change to 'Proposed Floor Plan') — see also review comments #2a -2c. Response: Please see the revised scope of work description, and detail #5 label has been changed To "Proposed Floor Plan". Also the original "bar" has been revised as "Beverage Service Station". 2. Project Data — Item #6 — Clarify the indicated occupant loads as follows: a. Entrance/Dinning (sic) Area — The indicated floor area appears to be a bit low and may not include the floor area adjacent the 'Beverage Serve Station'. If this area is to be used as a 'Bar' (patrons served/consuming drinks etc.) the appropriate occupant load factors per International Building Code (IBC) Table 1004.1.2 (i.e. 'Concentrated Assembly' or `Standing Assembly') must be applied. b. Kitchen Bar Area — The indicated floor area appears to be a bit high and to include an area identified as a 'Bar' (patrons served/consuming drinks etc.) and not part of the 'Kitchen' and its applicable occupant load factor. Any area to be used as a 'Bar' (patrons served/consuming drinks etc.) must have the appropriate occupant load factors per IBC Table 1004.1.2 (i.e. 'Concentrated Assembly' or 'Standing Assembly') applied. c. Bar/Rest Room (sic)/Hallway/Storage — The indicated area appears to include spaces not typically associated with `Accessory Storage Areas' per IBC Table 1004.1.2 and also uses an incorrect occupant load factor. Any area to be used as a 'Bar' (patrons served/consuming drinks etc.) must have the appropriate occupant load factors per IBC Table 1004.1.2 (i.e. 'Concentrated Assembly' or `Standing Assembly') applied. Areas such as 'Restrooms' and 'Hallways' are excluded from 'Net Floor Area' occupant load factors such as those for the 'Dining' area, but could be accounted for as part of the 'Kitchen' area. Response: Please see the revised project data item #6 for the revised occupant load calculations. The previous "bar" has been revised to be "Beverage Service Station" since the nature of the space is to prepare and serve all drinks and will use the same occupant load factor as the kitchen. A diagram is provided to show how the areas being calculated. August 29, 2012 12 123721 BZ Page 2of3 3. Min. Plumbing Fixtures (Group A) — Clarify the indicated ratio of the minimum required plumbing fixtures. It does not appear to coincide with that indicated for'A-2' occupancy groups in IBC Table 2902.1. Response: Please see the revised use has been changed from "A/2" to "B". Minimum plumbing fixture will be using Group B, occupant load 48 reference to IBC Table 2902.1 4. Detail # 4 — Reflected Ceiling Plan — Lighting Calculation - Clarify the indicated number of 'Wall Mount Lights' to be installed. It does not appear to coincide with that represented on the 'Reflected Ceiling Plan'. Response: Please see the revised wall mount lights fixture number has been changed from "11" to "12" and all calculation has been revised accordingly. 5. Detail # 5 — Proposed New Door Schedule a. Change the label to 'Proposed Floor Plan' to reflect that represented in the detail, Response: Please see the label for detail #5 has been changed to "Proposed floor plan". b. Clarify the indicated number of '49'forthe posting of the occupant load per IBC 1004.3. The 'posted' number is to only include that determined using the occupant load factor(s) for areas identified as 'Assembly' occupancies. Response: Please see the revised occupant load number indicated "48" according to the revised occupant load calculation. c. Change the identified element from 'Exit Sign' to 'Means of Egress Illumination' to reflect that indicated by the 'leader line'. Response: "Exit Sign" has been revised to "Means of Egress Illumination". d. Verify that the indicated 'swing' of the egress door is per IBC 1008.1.2 after recalculating the tenant space occupant loads in response to plan review comments #2a -2c above. Response: Please see the revised "swing out " of the egress door with side -hinged swing type per IBC 1008.1.2 for occupant Load (48) under 49 / Group B. e. Verify that the indicated number of exits or exit access doorways is per IBC 1015 after re- calculating the tenant space occupant loads in response to plan review comments #2a -2c above, Response: Provide one exit access doorway per IBC 1015 for the application of occupant load under 49 / Group B. f. Clarify the indicated 'Existing Walls' at the 'Host' and 'Waiting' areas. It does not appear to correspond to that proposed in detail #2 — Demo Plan. Response: A mistake of showing a section of "Existing Walls" at the "Host" and "Waiting" areas has been removed from the revised plan. g. Provide a reference as required to detail #8 — Partition Wall with Seismic Bracing (Perpen.) - for the required attachment at the top of walls that do not extend to and are attached to the roof structure. Response: A reference has been noted in detail #8 as the revised plan. August 29, 2012 12 123721 BZ Page 3 of 3 h. Clarify the indicated '(Existing)' type I hood — Type I Hood 1. There does not appear to be a record of an approved installation of a type I hood and the required fire suppression system. It could be included with the separate permit required for'Type I Hood 2'— see also review comment #7. Response: A correction note has been added on the plan for the "(Existing)" type I hood to be inspected and a new fire suppression system will be provided. i. Provide a note on the plans regarding the required maintenance of the minimum 1- hour fire - resistance rated occupancy separation walls per IBC 508.4 where applicable. Response: The minimum 1 -hour fire -resistance rated occupancy separation walls will not be needed due to the current occupancy is B. 6. Detail #6 — Proposed New Door Schedule a. Remarks - Change the applicable code version for each of the doors from 'ICC/ANSI 1117.1- 2003' to 'ICC A117.1-2009' to reflect that currently adopted. Response: Please see the applicable code version has been changed from "2003" to "2009" b. Indicate on the plans the required accessible door hardware for each of the doors per IBC 1008.1.9.1 and ICC A117.1-2009 section 404.2.6. Response: Please see a new reference has been added under the table of the proposed new door schedule address the accessible door hardware requirements. 7. Detail #7 — Kitchen Equioment (sic) Schedule — The required number, locations, etc. of the noted items (and of those not listed) are not part of this review and will be determined under separate permits and reviews by the appropriate agencies. Response: Please see the attached Health Department approval. Thank you for reviewing the project . Respectfully, Eddie King PO Box 2513 Issaquah, WA 98027