Loading...
20160405 15303 Firdale Remodel Struct Calc.pdf STRUCTURAL CALCULATIONS JOB NO: 15303 PREPARED BY: Alvin Chongmontre BCRA-Structural Engineer O: 253-627-4367 achongmontre@bcradesign.com Firdale Remodel 04/18/16 Page 1 of 9 Page 2 of 9 SCOPE OF WORK FOR REF ONLY 04/18/16 Firdale Remodel tƩƚƆĻĭƷ{ŷĻĻƷ bƚ͵ \[ƚĭğƷźƚƓ5ğƷĻ WƚĬ bƚ͵ .Ǥ PLAN SOUTHWEST PORTION alll wall being demoed are non shearwalls. 23'-7" 7'-11" " 6 - ' 0 1 Pmax = roof= 12ft/2 x 40 psf x 24ft/2=2880lbs provide 2ft x 2ft ok floor = 12ft/2 x (60+12) psf x 8ft/2= 2688 = 5.5k 2ft x 2ft x 1.5ksf = 6 k ok beam 1 GL 5 1/2 x 9 min Firdale Remodel 04/18/16 Page 3 of 9 tƩƚƆĻĭƷ{ŷĻĻƷ bƚ͵ \[ƚĭğƷźƚƓ5ğƷĻ WƚĬ bƚ͵ .Ǥ PLAN SOUTHWEST PORTION 5'-2" 16'-6" 1 0 ' - 1 0 " EX 2ND FLOOR PLAN 24'-0" EX ROOF PLAN Firdale Remodel 04/18/16 Page 4 of 9 PASSED MEMBER REPORT tower, beam 1 1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal. Design Results System : Floor Actual @ LocationAllowedResultLDFLoad: Combination (Pattern) Member Type : Drop Beam Member Reaction (lbs)4935 @ 2.00"7796 (3.50")Passed (63%)--1.0 D + 0.75 L + 0.75 S (All Spans) Building Use : Residential Shear (lbs)3572 @ 1' 0.50"8745Passed (41%)1.001.0 D + 1.0 L (All Spans) Building Code : IBC Pos Moment (Ft-lbs)11897 @ 5' 9.50"14850Passed (80%)1.001.0 D + 1.0 L (All Spans) Design Methodology : ASD Live Load Defl. (in)0.360 @ 5' 9.50"0.375Passed (L/375)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.511 @ 5' 9.50"0.563Passed (L/264)--1.0 D + 0.75 L + 0.75 S (All Spans) •Deflection criteria: LL (L/360) and TL (L/240). Bracing (Lu): All compression edges (top and bottom) must be braced at 11' 7.00" o/c unless detailed otherwise. Proper attachment and positioning of lateral • bracing is required to achieve member stability. Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 11' 3.00". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. • Bearing LengthLoads to Supports (lbs) Floor Supports TotalAvailableRequiredDeadSnowTotalAccessories Live 1 - Stud wall - HF3.50"3.50"2.22"1460289617386094Blocking 2 - Stud wall - HF3.50"3.50"2.22"1460289617386094Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. TributaryDeadFloor LiveSnow Loads LocationWidth(0.90)(1.00)(1.15)Comments Residential - Living 0 to 11' 7.00"5' 0.00"12.0100.0- 1 - Uniform (PSF) Areas 0 to 11' 7.00"12' 0.00"15.0-25.0 2 - Uniform (PSF) Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator 4/6/2016 9:27:17 AM Forte Software OperatorJob Notes Forte v5.0, Design Engine: V6.4.0.40 Alvin Chong 15303.4te BCRA (253)627-4367 achongmontre@bcradesign.com Page 1 of 1 Firdale Remodel 04/18/16 Page 5 of 9 tƩƚƆĻĭƷ{ŷĻĻƷ bƚ͵ \[ƚĭğƷźƚƓ5ğƷĻ WƚĬ bƚ͵ .Ǥ INTERIOR SPACE 4x8 header typ min Pmax = 700lbs ceiling beam 4x10 min Firdale Remodel 04/18/16 Page 6 of 9 tƩƚƆĻĭƷ{ŷĻĻƷ bƚ͵ \[ƚĭğƷźƚƓ5ğƷĻ WƚĬ bƚ͵ .Ǥ GRAVITY DESIGN BEARING 16'-10" BEARING 11'-7" 45'-5" 19'-9" 11'-8" BEARING 23'-1" 17'-1" BEARING Firdale Remodel 04/18/16 Page 7 of 9 PASSED MEMBER REPORT interior header, header typ 1 piece(s) 4 x 8 Douglas Fir-Larch No. 2 All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal. Design Results System : Wall Actual @ LocationAllowedResultLDFLoad: Combination (Pattern) Member Type : Header Member Reaction (lbs)1034 @ 03281 (1.50")Passed (32%)--1.0 D + 1.0 S (All Spans) Building Use : Residential Shear (lbs)679 @ 8.75"3502Passed (19%)1.151.0 D + 1.0 S (All Spans) Building Code : IBC Moment (Ft-lbs)1098 @ 2' 1.50"3438Passed (32%)1.151.0 D + 1.0 S (All Spans) Design Methodology : ASD Live Load Defl. (in)0.012 @ 2' 1.50"0.142Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.020 @ 2' 1.50"0.213Passed (L/999+)--1.0 D + 1.0 S (All Spans) •Deflection criteria: LL (L/360) and TL (L/240). Bracing (Lu): All compression edges (top and bottom) must be braced at 4' 3.00" o/c unless detailed otherwise. Proper attachment and positioning of lateral • bracing is required to achieve member stability. Applicable calculations are based on NDS. • Bearing LengthLoads to Supports (lbs) Supports TotalAvailableRequiredDeadSnowTotalAccessories 1 - Trimmer - SPF1.50"1.50"1.50"3966381034None 2 - Trimmer - SPF1.50"1.50"1.50"3966381034None TributaryDeadSnow Loads LocationWidth(0.90)(1.15)Comments Residential - Living 0 to 4' 3.00"12' 0.00"15.025.0 1 - Uniform (PSF) Areas Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator 4/6/2016 9:34:20 AM Forte Software OperatorJob Notes Forte v5.0, Design Engine: V6.4.0.40 Alvin Chong 15303.4te BCRA (253)627-4367 achongmontre@bcradesign.com Page 1 of 1 Firdale Remodel 04/18/16 Page 8 of 9 PASSED MEMBER REPORT interior header, ceiling beam 1 piece(s) 4 x 10 Douglas Fir-Larch No. 2 All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal. Design Results System : Roof Actual @ LocationAllowedResultLDFLoad: Combination (Pattern) Member Type : Drop Beam Member Reaction (lbs)702 @ 2.00"5206 (3.50")Passed (13%)--1.0 D (All Spans) Building Use : Residential Shear (lbs)629 @ 1' 0.75"3497Passed (18%)0.901.0 D (All Spans) Building Code : IBC Moment (Ft-lbs)3496 @ 10' 3.50"4043Passed (86%)0.901.0 D (All Spans) Passed Design Methodology : ASD Live Load Defl. (in)0.000 @ 00.675--1.0 D (All Spans) (2L/999+) Member Pitch: 0/12 Total Load Defl. (in)0.699 @ 10' 3.50"1.013Passed (L/348)--1.0 D (All Spans) •Deflection criteria: LL (L/360) and TL (L/240). •Bracing (Lu): All compression edges (top and bottom) must be braced at 20' 7.00" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. •Applicable calculations are based on NDS. Loads to Supports Bearing Length (lbs) Supports TotalAvailableRequiredDeadTotalAccessories 1 - Stud wall - SPF3.50"3.50"1.50"702702Blocking 2 - Stud wall - SPF3.50"3.50"1.50"702702Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. TributaryDead Loads LocationWidth(0.90)Comments 0 to 20' 7.00"6' 0.00"10.0Roof 1 - Uniform (PSF) Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator 4/6/2016 9:36:00 AM Forte Software OperatorJob Notes Forte v5.0, Design Engine: V6.4.0.40 Alvin Chong 15303.4te BCRA (253)627-4367 achongmontre@bcradesign.com Page 1 of 1 Firdale Remodel 04/18/16 Page 9 of 9