20160422153013.pdfCity of Edmonds PLAN REVIEW" COMMENTS DATE: April 18, 2016 TO: Chermak Construction Dana Chermak dana@chermak.com FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2016-0243 Project: Bodal Addition/Remodel Project Address: 16905 Talbot Road Hello, Thank you for your comments. Please see revision notes following below your notes: During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. 1. The application indicates that 2 water closets are to be installed, but only one new water closet could be found on the plans. Please clarify. Clhermalk: Adjusted application: No new water closet, only bath next to (kitchen to Ibe added. 2. Similarly, the sink count could not be reconciled with 4 on the application but only 3 found on the plans. Clherrnak: Changed applllication to match. Also added, Rxture Il ew and Existing, note to A-6 3. Identify on the plans how the requirements regarding whole -house ventilation will be satisfied per IRC M1507.3. Chermak: Added Whole III°°(louse Ventilation note and schedulle to A-6 4. The application indicates the presence of a gas furnace in the basement, and a heat pump at the NW exterior of the home. Are these new pieces of equipment? If so, is the path of compliance to the Washington State Energy Code (WSEC) section R406? In any case, please indicate on the plans how the requirements of Section R406 will be satisfied. Specify which option(s) from Table R406.2 will be utilized to achieve the required credits. Sheet A-4 Chermak. We will be using the prescriptive path: see new compliance sheet. Mechanicals will be permitted at later date by hvac professionals. 5. Please show the smoke detectors throughout the house as required per IRC R315, i.e. within each sleeping room and outside of and in the vicinity of the sleeping room area(s). Note all of the smoke detectors within the residence must be hard -wired and interconnected. Chermak: Smoke detectors alre Irnore clearly (noted and Ilnterconnected in new space with notes on A,,,.6, C'Mty of Edmonds PLAN REVIEW COMMENT'S BUILDING DIVISION (425) 771-0220 Page 2 of 2 6. In the same area, there is a note indicating the existing 2x8 deck is to be used for the kitchen floor. However, detail 9/S5.1 shows that the floor joists are to be replaced and W plywood decking is indicated. Please revise. Clhermak: Changed allll inotatlons on A-5 to match S5.1 7. Detail 2/A-4 appears to have the proper information for insulating the slab per WSEC Table R402.1.1. Please reference the detail with a detail bug in an appropriate location indicating a 'typical' condition to help guide proper inspection. Sheet A-5 Clhermak: E--, xtra Sheet added for (Riot Ran, l°°°oundatioin Pllan lis snow A,,," . Added foundation insulation detains to A-5 and added callllouts at F::�nd. II,,,,.ocations" 8. Similar to Item #5 above, please show the smoke detectors throughout the house as required per IRC R315, i.e. within each sleeping room and outside of and in the vicinity of the sleeping room area(s). Note all of the smoke detectors within the residence must be hardwired and interconnected. Ctmeirimak: Added ed Smmmmmllke detectors to eA t:ium° g aind new lmmamat.loris and not:es to . 6 9. Please indicate on the plans and in the window schedule that window W03 in the New Bedroom is to meet the emergency escape and rescue requirements of IRC R310.1. Sheet A-6 Cherrnak; Added egress to plan and all Views slhoWng window. 10. Per WSEC Table R402.1.1, insulation is required to have an R-49 rating in ceilings (R-38 if vaulted), and R-30 within floor assemblies. Please verify these requirements are labeled correctly. Cheirrnak: Adjusted alll motes and details to complly Wtlh liinsulat'ion code"