Loading...
20160429104329.pdfstj B City of Edmonds Building Department AN? 1,8 2016 620 Glen Street EIUILCAING [)�`FJ FTIME I BLD2015-0771 CRY OF EDMO DS 4 unit condo 1. The applicant has revised and resubmitted the special inspection form 2. See response from BTL engineering 3. An additional CO2 detector has been added outside the sprinkler room We have revised the doors per ICC A117.1- 2009 Table 404.2.3.2 See general note in regards to the rating needed for the shaft enclosure and machine room One hour rated door noted on machine room See general note requiring self closers on all one hour rated doors See note in regards to fan being added to machine room See response from BTL engineering See response from BTL engineering Threshold code note revised See response from BTL engineering See response from BTL engineering 4. The applicant wants to install electric tankless water heaters in each unit that will supply hot water for the hydronic heaters noted on the plans and potable water for bathing. The applicants contractor has installed this system before and can provide documentation on the requirements for this type of heating system 5. Self closing general note added See required fire stopping note and materials to be used The floor assembly we are using from the Gypsum Association Manual was tested with 401b carpet and pad. We are using carpet in the bedrooms and laminate wood flooring and tile in the kitchen, great room, and bath areas. The fire rating was done according to the manual with no flooring. The sound test was done by using carpet. We are choosing this assembly for its one hour fire rating which is required by code Washer and dryer revised to a standard set of units Door widths revised Pocket door note added Threshold note added 6. CO2 detector added Smoke detector added Entrance door revised Type B bathroom revised to note no cabinet under the sink and the approach as a parallel approach Fan CFM noted See response from BTL engineering See response from BTL engineering See response from BTL engineering 7. Note revised to 3/8" Note removed from plans for use of fire caulk. No HVAC ductwork is planned for this project Mike Johnson Nash and Associates Architects A "r- "A" "A nn I � 64 1, N F, 84)... STR I"I','T 0 K I R K LA N D, WA 0 980 VI 0 i125X'28-11 117 W'\X�W,,NA.Sli-A,RCHI"I'EC'I'S.COM