2016-0462 Rutledge (Hapke).pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: May 19, 2016 TO: Rory S. Rutledge, Sr. rsrutledge@comcast.net FROM: Andrew Gahan, Plans Examiner RE: Plan Check: BLD2016-0462 Project: Rutledge Addition nd Project Address: 7717 192 Place SW During a review of the plans by the Building Division for the above noted project, it was found that the following information, clarifications, or changes are needed. A complete review cannot be performed until the revised plans/documents, including a written response indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments. Sheet 6 1.Please provide dimensions such that the appropriate spans can be identified for review. 2.It appears that the interior 6x12 is overstressed as shown. Please provide calculations to verify its adequacy or upsize the beam. Sheet 7 3.The detail regarding exposed raised beams should be revised to show a strap across the beam end to provide continuity at the double top plate. 4.Per item #2 above, the interior 6x12 appears overstressed. Sheet 8 5.Please provide room names or some way to identify the use of each room. For example, it appears that the room adjacent to the bathroom may be intended as a bedroom. 6.Provide enough dimensions to determine the locations of windows, doors, fixtures, etc. from the drawings. 7.Provide smoke detectors within the bedroom and outside of and in the vicinity of the bedroom per IRC R314. 8.Provide a carbon monoxide detector per IRC R315. 9.Provide a minimum 50 CFM exhaust fan within the bathroom per IRC M1507 as amended by the State of Washington. 10.If the room adjacent to the bathroom is meant to be a sleeping room, please verify that one of the windows meets the emergency escape and rescue requirements per IRC R310. 11.It appears that a kitchen/kitchenette is intended for the main room of the addition. Please verify if this will be a kitchen. If it will be a kitchen, please verify if the kitchen will be equipped with a refrigerator requiring plumbing, a range/over requiring gas plumbing and/or mechanical exhaust. 12.It appears that the addition has the potential for being considered an Accessory Dwelling Unit (ADU). If so, please be informed that the smoke detectors throughout the entire structure (existing and new) will need to be upgraded such that they are hardwired and interconnected. Alternatively, the entire ADU would need to provide 1-hour fire separation from the existing dwelling. 13.Please show the location of the on-demand water heater. Sheet 9 14.Please provide dimensions on the plan to facilitate a structural review of the members selected. Or, verify that the drawings are to scale and omit the ‘Not to Scale’ demarcation. Sheet 13 15.Note on the plans that any wood portion of the structure shall be 6” minimum above finished grade, or such members are to be specified as pressure treated or another approved weather- resistant product. Sheet 15 16.Note that existing exterior 2x4 walls are to be upgraded to R15, the maximum attainable R- value within a 2x4 wall. 17.Please clarify if the collar ties will be installed. The roof framing plan shows that the rafters will be supported by a ridge beam at the high end, yet the section view on Sheet 15 shows no ridge beam, but shows collar ties instead. Sheet 16 18.Please provide details and/or specifications regarding the following connections: a.Lateral connections from the upper floor framing to the lower floor walls. b.Connections from the upper floor framing to the new support beams below. c.Connections from the center post and angled braces between the roof rafters and the roof beam below. Page 2 of 2