Loading...
20160517141234.pdfNII IIIANN.) A. FIISIIIIN::If? ARC; Id ITECr1 S May 12, 20:1$6 City of Edmonds Building Division RE: Plan review comments response Petemm Resideme 820 Mle Strreet Plan Check: BLD2016-0421 Attn: Chuck Miller, Plans Examiner Detached Garage: 1. Dimensions added to sheet A2.0 tot SIO showing 16'4' gavage door, opening with 4%0" side :shear walls each side 2. Per our conversation the 2-2x10 header holds per calculation for the 16'-0" span. Main Floor Plan: a. Smoke alarm per IRC R314 added to sheet A2.0 b.Carbon Monoxide alarrn pu IRC R315 added to sheet, A2.4 -c. Mud Ro(inn,dooris a new replacement door. Size noted on sheet A2.0 d. Mud room door header noted on sheet A2.0 Attic Plan: a. Attic space has been previously used as living space, with existing stairway access. Attic was previorusly,heated with existing R-11 insulation in the ceiling rafter cavity. Per detail on sheet A2.1and d AIO the R-11 will be removed, a 2x6 will be sistered onto each rafter and closed cell foam insulation added to the rafter cavity. ICC -ES evaluation report on insulation is added for review. b. Existing attic floor system is a fu112"x10" @ 16" o.c.. The existing rafters are a full 2"x 4". No structural additions or changes are involved in the attic area, beyond the added 2x6 to the rafters. All walls shown are non-bearing and area behind walls are re h oved from, possible storage loads. ;Existing stairway is modi:fi d to replace 3pw shaped' mid, landing treads with 2= YxYmid haulings. c. Emergency egress noted on west window on sheet A2.1 d. Smoke alarm added to sheet A2.1 e. Carbon monoxide alarm added to sheet A2.1 f. Windows noted in attic area (A2.1) are new thermal paned, U value .3 0, replacing existing older single paned windows. g. Headers over attic window added'to sheet A2.1 , V A 1.1V V VVIR C,8 .l ill '' l� d 411 4.7 4'1'" h: Width of mid level landing, awl stairway width, are 3%flr finish. l inwnsions add to sheet A►2.1 i. Safety glazing note added to stairway windows Upper Floor Plan: a. Smoke alarms added to each sleeping room and one outside in vicinity of bedrooms, ad to sheet A2.1 b. Carbon. numoxide ,alarm Mdded to outside of sleeping area,on second floor, ,on sheet A2.1 c. Header over stairwell window and safety glazing note added to sheet A2.1 Chuck, I appreciate your attention to this project and enjoyed discussing "old homes" with you. :Sincerely, Richard A Fisher Project Architect