20160603112419.pdfLetter of Transmittal June 3, 2016 Project Info: CRS# 60332787 Swedish Edmonds Chapter 246-320 WAC Hospitals New Ambulatory Care Center Key People: Assigned DOH Kevin A. Scarlett, RA, ASHRAE HFDP Reviewer: kevin.scarlett@doh.wa.gov Facility Swedish Edmonds Administrator: Sarah Zabel 21601 76a' Ave W Edmonds, WA 98026 (425) 640-4005 x. sarah.zabel@swedish.org Architect / NBBJ Engineer: Chuck Kolb 223 Yale Avenue North Seattle, WA 98109 (206) 223-5009 x. ckolb@nbbj.com Consultant: KPFF (Civil) Scott Meurn 1601 5'h Ave Ste 1600 Seattle, WA 98101 (206) 622-5822 x. scott.meum@kpff.com Contact: KPFF (Structural) Tom Hudgings 1601 5th Ave Ste 1600 Seattle, WA 98101 (206) 622-5822 x. tom.hudgings@kpff.com Copies To: ® Local Al -IJ: City of Edmonds ® Architect / Engineer: NBBJ ® Consultant: KPFF (Civil) ® Consultant: Sparling (Electrical) ® Contact: KPFF (Structural) ® Contact: CDi Engineers ( Mechanical & Plumbing) ® CRS File d� Washington State Department of H-11the," Construction Review Services 111 Israel Rd. SE Tumwater, WA 98501 PO Box 47852 Olympia, Washington 98504-7852 www.doh.wa.gov/crs tel. 360-236-2944 fax. 360-236-2321 Project 21601 76th Ave W location: Edmonds, WA 98026 Local Permit #: Facility Contact: Providence Health & Services Jim Grafton 600 Broadway Suite 304 Seattle, WA 98122 206-215-3531 x. James.Grafton@providence.org Local AHJ: City of Edmonds Leif Bjorback 121 5th Avenue N. Edmonds, WA 98020 (425) 771-0220 x. bjorback@ci.edmonds.wa.us Consultant: Sparling (Electrical) Maureen Jackson 4100 194`}' St SW Lynnwood, WA 98036 (206) 667-0553 x. mjackson@sparling.com Contact: CDi Engineers ( Mechanical & Plumbing) Finn Jakobsen 19203 36`h Ave W Ste 200 Lynnwood, WA 98036 (425) 672-1071 x. fjakobsen@cdiengineers.com ❑ DOH Child Birth Center Licensing ❑ DOH Office of Accommodations & Res. Care Survey ❑ DOH Office of Investigations & Inspections DSHS, Div. Of Alcohol & Substance Abuse DSHS, Aging & Adult Services Admin. ® L&I, Bill Eckroth, Electrical Section ❑ L&I, John Harvey, Factory Assembled Structures Page 1 of 17 Plan Review Comments for Project 460332787 Swedish Edmonds Chapter 246-320 WAC Hospitals New Ambulatory Care Center on 11-5-15 in conjunction with on site verification/inspection (along with a two day follow-up inspection) by City Fire Inspector Kevin Zweber. —kas 32 El Verify the following items within the Behavioral Health Area; a) Anti ligature hardware on exam room doors. b) Access panels have standard screwdriver operation latches; tamper resistant. c) hardware on the public side of the Exam room nurse server doors. d) Remove the plumbing box for the washer in Soiled Utility 0103.062. e) Pressure differential monitors in Isolation Exam Rooms, 0103.15 and 0103.16. f) Ice Machines, 1" air gap at filler trays and indirect waste. These items must be field verified/inspected for approval. —kas Approved 11/24/15 — based on site inspection performed by DOH/Kevin A. Scarlett on 11-5-15. —kas The following comments address the revision/submittal of the portion of Phase 3 of the ACC project relating to modification of the exit passageway portion of the project. -kas 33 0 This `exit passageway' portion of the project has been reviewed and appears to be in compliance with all applicable codes and regulations with no additional comments. -kas The following comments address the submittal of the the cooling towers which were received on 5-23-16. -kas 34 El Provide an RPBA on the domestic water feed for these two cooling towers. Provide Make & Model number (and product data cut sheets) for the RPBA device. Should an existing RPBA be present and intended for re -use, the Owner/Engineer can verify and reply to this comment with the existing Make & Model number and the statement of intent to re -use. 35 D Other than comment #34 above, this cooling tower portion of the project has been reviewed and appears to be in compliance with all applicable codes and regulations with no additional comments. -kas Compliance with the comments above provided by the Department of Health Construction Review Services are necessary for this facility to meet the requirements of the applicable licensing regulations found in the Washington State Administrative Code and associated references. These comments do not relieve the facilityfrom the responsibility to meet the requirements of any other applicable federal, state or local regulations. In the event of conflicts between other jurisdictions and these written comments, the most stringent shall apply. Page 17 of 17 Plan Review Comments for Project # 60332787