2016-0661 Fashion Dim Sum TI2 - 3-D Design.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: August 23, 2016 TO: Wenke Yang wenkeyang312@yahoo.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2016-0661 Project Address: 22923 Highway 99, Suite J Project: Fashion Dim Sum TI Scope: Add non-bearing interior walls, two restrooms, type I hood – B occupancy group – 32 occupants – III-B construction – no NFPA-13 sprinkler system – mechanical and plumbing included disapproved Please be advised that the building plans for the above referenced project have been for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following . information, clarifications, or changes are neededReviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. nd Resubmittals must be made at the Development Services Department on the 2 Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. On sheet A-3 – Bracing Detail & ADA Restrooms: 1.Detail B – Restrooms, Detail 2 – Mens Rest Room Elevation, Detail 3 – Womens Rest Room Elevation, and Detail 5 – Typical Side Elevation – Clarify on the plans the indicated length and/or placement of the following: The rear wall grab bar – height and centered length with extension · The side wall grab bar – height · The vertical grab bar – height and distance from rear wall · They do not appear to comply with ICC A117.1-2009 section 604.5. On sheet FS-1 – Equipment Plan: 2.Equipment Schedule 1 a.Indicate on the plans the required installation of Type II hoods above the following appliances that produce heat or moisture per International Mechanical Code (IMC) 507.2.2: Mark ‘10’ – Cabinet Heater/Proofer · Mark ‘14’ – Electric 3 Pan Steam Table · An HVAC system design that incorporates the heat and moisture loads from the appliances or a separate removal system are acceptable alternatives that must be noted on the plans. Spaces containing cooking appliances without Type II hoods shall be provided with exhaust at a rate of 0.70 CFM per square foot. b.Clarify on the plans the difference in the number of ‘CanPlas Grease Trap’ – Mark ‘42’ – to be installed and of that represented on the plumbing plans/line drawings dated August 12, 2016. On sheet FS-2 – Plumbing: 2.Detail 1 - Plumbing a.Provide on the plans a ‘mark’ for the following items: Mark ‘21’ – Water Heater On Demand · Mark ‘23’ – Floor Drain – for the additional locations in the restrooms · represented on the plumbing plans/line drawings dated August 12, 2016 Mark ‘42’ – CanPlas Grease Trap – below the ‘3 Comp Dirty Dish Table’ in the · ‘Scullery’ and as required in response to plan review comment #2.b above b.Clarify on the plans the indicated location of the water supply and DWV for the following: Mark ‘9’ – Hand Sink w/Fct · Mark ’16.1’ – Wall Mt Faucet · 3.Plumbing (Schedule) a.Add to the schedule on the plans the following fixture and its applicable plumbing requirements: Mark ‘42’ – CanPlas Grease Trap – below the ‘3 Comp Dirty Dish Table’ in the · ‘Scullery’ b.Provide on the schedule on the plans the noted information for the following fixtures: Mark ‘16’ – Veg 1 Comp Prep Sink – the required indirect drainage connection · in the ‘Plumbing Remarks’ Mark ‘17’ – Meat 1 Comp Prep Sink – the minimum trap arm size and the · required indirect drainage connection in the ‘Plumbing Remarks’ Mark ’21’ – Water Heater On Demand – the minimum cold water supply size · and gas piping size Mark ‘33’ – Water Closet – the direct drainage connection size · Page 2 of 3 On sheet FS-2.1 – Plumbing Rough-In: 4.Plumbing Plans/Line Drawings (dated July 22, 2016 and dated August 12, 2016) a.Clarify on the plans the difference in the type and number of fixtures/appliances represented and of that indicated on sheet ‘FS-1’ – Equipment Plan – and sheet ‘FS- 2’ – Plumbing. The plans must consistently represent the proposed work to guide proper review, construction, and inspection and to accurately determine the permit fees to be assessed for the permitted work. b.Clearly indicate on the plans the City of Edmonds Pretreatment Technician requirement that the ‘pre-wash sink’ (the location where the soiled dishes are rinsed prior to being placed in the dish machine/dishwasher) must drain to a grease trap. On sheet FS-3 – Electric: 5.Electric Schedule - Add to the schedule on the plans the following appliance and its applicable electrical requirements: Mark ‘8’ – Undercounter Refrigerator · On sheet FS-4 – Elevations: 6.Detail 2 – Mens Lav – Clarify on the plans the indicated height and centered length with extension of the rear wall grab bar. 7.Detail 3 – Womens Lav – Clarify on the plans the indicated centered length with extension of the rear wall grab bar. They do not appear to comply with ICC A117.1-2009 section 604.5. Page 3 of 3