2016-0669 Swedish Radia Imaging TI - AWerks.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: June 30, 2016 TO: Radia Medical Imaging Stephanie Aplin saplin@radiax.com FROM: Chuck Miller, Plans Examiner RE: Plan Check: BLD2016-0669 Project Address: 21700 Highway 99 Project: Radia Medical Imaging TI Scope: Remove overhead door/add infill wall & windows, remove/add interior non- bearing walls, new suspended ceiling/lighting/controls – B occupancy group – 58 occupants – V-B construction – no NFPA-13 sprinkler system installed – mechanical, plumbing, and fire system alteration/addition under separate permits disapproved Please be advised that the building plans for the above referenced project have been for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following . information, clarifications, or changes are neededReviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. nd Resubmittals must be made at the Development Services Department on the 2 Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. On sheet A2.1 – Floor Plan: 1.Floor Plan a.Indicate on the plans the required drinking fountain(s) installation to meet both the accessible and standing spout outlet height requirements of International Building Code (IBC) 3411.7/2902.5.1/1109.5.1 and ICC A117.1-2009 section 602.4. b.Clarify the elevation bubbles as follows: ‘1/A7.1’ in space ‘118’ – Ultrasound Techs · ‘2/A7.1’ in space ‘119’ – Scheduling · ‘3/A7.1’ in space ‘124’ – Ultrasound · Sheet ‘A7.1’ does not appear on the ‘Sheet Index’ on sheet ‘A0.1’ and could not be found among the submitted construction documents. c.Identify on the plans the proposed elements to be placed along the north interior wall of space ‘119’ – Scheduling – to guide proper review, construction, and inspection. On the provided Washington State Energy Code (WSEC) Compliance Forms for Commercial Buildings checklist ‘LTG-CHK’: 2.Lighting Controls – Clarify the stated indication of identified locations for the installation of the following: a.Light reduction controls per WSEC C405.2.1.2 b.Occupancy sensors per WSEC C405.2.2.2 c.Means of egress lighting per WSEC C405.2.3 – item 7 d.Exit signs per WSEC C405.4 The controls and type of fixtures required by WSEC do not appear to be indicated on the plans or in the ‘Light Fixture Schedule’ on sheet ‘A3.1’. Page 2 of 2