Loading...
20161114111558354.pdf2707 Wetmore Avenue Everett, WA 043MO I t 425.387_3820 f 425_2550-195$ November 14, 2016 City of Edmonds Via email: jennifer.lambert@edmondswa.gov RE: Coleman SFR — Pump Tank Discharge Pipe Material Dear Staff, I was provided information from the contractor who installed the stormwater pump system in regards to the pipe material used for the pump discharge line connecting to the detention system on -site. The pipe material used was PVC Sch. 40 (300-psi). This was not one of the approved materials provided by the City on the approved engineering plans. However, this material is regularly used for water line installations with much higher pressure demands then this system. The maximum pressure expected in the force line for this project is less than 60 psi which is nearly a quarter of the pressure specification for this product. Therefore, this material will function as expected with no additional risk of failure or higher maintenance costs or frequency. Thank you for taking the time to review this project. Please feel free to contact me with any questions you may have. Sincerely, Joseph Smeby, P.E. Project Engineer # k 13T Cis����i � 1N L