2016-1581 Enfort homes.pdfOV EQ_4 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: March 15, 2017 TO: Greg Lynch, Enfort Homes Greg@Enforthomes.com FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2016-1581 Project Address: 7508 210'h ST SW Scope: Construct I- two family dwelling — R-3/U occupancy group — V-B construction— mechanical and plumbing included Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicatin2 where the 'clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. Sheet A2: 1. The center pier located in the row of isolated piers closest to the exterior wall on both units A and B is specified to be 24"x24" per engineering. Indicate this change on the plans to guide construction and field review. 2. The center post supporting the floor framing and point loads above located in the row of piers closest to the exterior wall on both units A and B is specified to be a 6"x6" post per engineering. Indicate this change on the plans to guide proper construction and field review. Sheet A3: 3. Per IRC 308 Sliding glass doors are to be "Safety Glazed". Indicate on the plans to aid proper construction and field review for both units A and B. 4. Per IRC 1307.3.1 the furnace and water heater shown on the plans will need to be provided with "impact protection" for both units A and B. Indicate on the plans to guide proper construction and field review. 5. The powder room and kitchen fans for both A and B units are required to comply with IRC M1507.4 for exhaust rates. Indicate the fan rates on the plans to guide proper construction and field review. Sheet A-4: 6. Clarify on the plans which size of header(s) are to be used along the rear of the building for A and B units. 7. The 5 1/8" x 12" GLB specified on the plans for the upper floor framing is different than what appears to be specified in the engineering for both A and B units. Clarify on the plans to guide proper construction and field review. Sheet A-5: 8. The 4/0 x 3/0 OX window shown in the master bathroom must be "safety glazed" per IRC 308 on both A and B units. Indicate on the plans to guide proper construction and field review. 9. The bathroom and laundry fans for both A and B units are required to comply with IRC M1507.4 for exhaust rates. Indicate the fan ratings on the plans to guide proper construction and field review. General: 10. Per energy code worksheet submittals, option 3B was selected. 3B requires a ground source heat pump with a minimum of 9.0 HSPF. Indicate on the site plans the size and locations of where these units will be placed for both A and B units. This will guide thorough and proper review. 11. Per energy code worksheet submittals, option 5C was selected. Identify on the plans what type of appliance and locations for both A and B units will be used. 12. Per IRC M1507. Whole house ventilation is required; identify on the plans what method is to be used. This will guide thorough and proper review. Page 2 of 2