Loading...
20170104150255.pdfNovember 29, 2016 To: Plans Examiner Attn: Chuck Miller Harvey Prickett Wave Design Group Via Email: �"tur�r @1rra a �s11 This is response to your comments for this project. Igor RE: REVIEW COMMENTS • BLD-2016- � • Tenant Improvements 5 corners Deli - Market 8406 Bowdoin Way The following items shall apply to the proposed construction in accordance with the Kennewick Municipal code and the 2015 International Building, Fire and other adopted codes. 1. Deferred (sic) Submittals — Indicate on the plans the required submittal of construction documents for the proposed installation of mechanical, plumbing, and electrical systems under separate permits. While the Washington State Department of Labor of Industries has regulatory oversight of the electrical system installation, the means of compliance of the system and its components with the applicable provisions of the Washington State Energy Code (WSEC) must be represented on the plans per WSEC C103.2 — see also review note 8. Codee l Il l) haaric R'Xii°n°n. 2. Wall Types — Wall Type 'B' — 1 Hr. Wall — Provide on the plans the required installation criteria of the fasteners (type, diameter, length, head, spacing, etc.) used to attach the gypsum wallboard per the referenced fire -resistance rated wall assembly to guide proper construction and inspection. µ wd;�M"�p.11�..R'II�s�"P. .R,evsed, "".e sIIe"t G.N.d wl0. On sheet G-001 — ADA Standards: 3. Ramps — a. In the note regarding the slope of ramp landings change on the plans the maximum slope from `1 /58' to `1 /48'. b. In the note regarding the counter slope of curb ramps change on the plans the maximum slope from '1/30' to '1/20'. 4. Detail 1 — Typ A.D.A. Restroom Plan —Hardware General Notes a. Note 1 — Eliminate, or update to reflect that applicable to this project, the referenced code sections on the plans regarding door -opening force. b. Note 4 — Eliminate, or update to reflect that applicable to this project, the referenced code section and information on the plans regarding door closers. Rep.:.nSE:: IV' �.:Wlised, See s: ,,ueet Via:.-001. 5. Detail 2 — Typ A.D.A. Restroom Section — In the middle section change on the plans the required minimum required clearance width around the water closet from '36 inches min.' to '60 inches min.' per ICC A117.1-2009 section 604.3.1. On sheet A-111 — Floor Plan: 6. Floor Plan — Notes: Note 6 — Change on the plans the wording of the readily visible sign required for the installation of key -locking hardware from '...during regular business hours.' to '...when this space is occupied.' per International Building Code (IBC) 1010.1.9.3. C:.ZesIl nMn S.: li:Revilsed See sheet _,I ,11 'll On sheet A-112 — Equipment Placement Floor Plan: 7. Equipment Placement Floor Plan - Indicate cn the plans any shelving/racks that exceed 6 feet in height. They must be seismically anchored per American Society of Civil Engineers (ASCE) chapter 15. On sheet A-121 — Reflected Ceiling (sic) and Lighting Plan: 8. Reflected Lighting Plan - Provide as part of a complete permit application submittal 2015 Washington State Energy Code (WSEC) 'Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1' as required for the selections noted on the 'Interior and Exterior Lighting Alterations' section of the WSEC Lighting Summary — LTGSUM. The completed forms must include 'LTG-INT-SPACE', 'LTG-INT- BLD', and 'LTG-CHK', as applicable, at a minimum to support the proposed lighting installation. Specific attention needs to be given to the proposed track -lighting in the 'Beverage Area' per WSEC C405.4.1, form 'LTG-INT-SPACE' Note 7, and form 'LTG- INT-BLD' Note 6. Cojj-jjrjiAarice lm oIrirn, 9. RCP Legend — In the note regarding the exterior landing emergency lighting change on the plans the referenced code section from `1006.3' to '1008.3.2'. On sheet A-602 — Door & Window Schedule: 10. Door Schedule — Frames — Type — Clarify on the plans the door frame type callouts for the following 'marked' doors: 102 —103 —104 - 105 They do not appear to reflect that suggested by the indicated frame material and referenced in detail '2/A-602'. 1:°�esi°lionse, gee sheet 4,..,p .� .,p . Regards, m_ Harvey D. Prickett - Principal