Loading...
20170118153136.pdfRESUB JAN 17 2017 DATE: January 17, 2017 BUILDING l;t ER E °I" RESPONSE TO PLAN REVIEW TO: ENGINEERING DIVISION FROM: Selena Fitch RE: Application #: BLD20161529 Project: Waite— Addition Project Address: 8310 — 184th St SW During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Reviews by other divisions, such as Planning and Building, may result in additional comments. Please redline plans or submit three (3) sets of revised plans/documents with a written response to each of the items below to a permit coordinator. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm. The Permit Center is closed on Wednesdays. City of Edmonds handouts, standard details and development code can be referenced on the City website. Please Note: Building Handouts do not include updated Engineering Division Requirements. Refer to Engineering Handouts for all Engineering Requirements. 1) Show all impervious areas on the site plan (i.e. walkways, patios, etc.). Co!rrtacted a) If the areas are to be removed, please show them on the plans and label to be removed. C'o rret,ted b) Any existing impervious area that is to be removed and replaced where the new addition is to be placed can be shown as it currently is on the submitted plans. Corrected c) The driveway is not shown as it exists. Please revise the plans accordingly. Cor rectc(l. 2) Impervious areas are calculated as new impervious surface areas for any areas added to the site after 1977 or where existing impervious areas are to be removed to bare soils. The only exemption (not counted as new impervious area) is the repair of driveways and walkways. a) Please label the year of construction for all impervious areas on the subject site. Done b) It appears that there was an addition completed in 1979. Please clearly show this addition on the plans and revise the impervious surface calculations accordingly. Done 3) Show the sewer line from the house to the sewer main. If the addition is placed over the sewer, a cleanout is required on the side sewer within 2' of the structure. If a cleanout will need to be added (due to the addition), please note as such on the plans. S110WN ON PLAN, O (1 1,',ANOI JT 1 Enl;i Ei:: 4) Show the water service line from the meter to the house. Done 425.776.1367 • FAX 425.774.4993 • 655 Edmonds, Way • Edmonds, Washington 98020