Loading...
20170306162336.pdfIPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that otters conlact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This single or dual 2111 com- municator connects directly to the primary and secondary communication potis of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which Include- Celkilar only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM.4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The stale of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNel has the abdty to route messages using Alarnri and 800 PLUS services, providing true redundancy and multipath message delivery. Alternative communication methods are critical in the market- place due to VoIP (Vo�ce over IP). migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-4G's single path communications solution allows one technology to be used (Either IP or cellular) to provide the appropriate connectivity to a central station. For added reliabil- ity, our exclusive dual path solution allows both technologies (P and cellular) to be used together for maximum survivability or for local jurisdiction requirements that specify a clual tech- nology system. The I PGSM-4G is designed to operate over the most common cellular networks including 2G,3G and 4G. Its multi -GSM plat- form technology automatically chooses the best available cel- lular signal In the area based on signal strength and seamlessly self-adjusis to maintain critical life safety communk Galion. In addition, It connects to any type of customer pro- vided Ethernet 101100 base network connection (LAN or WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or dual path solution as well as Inin. appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for selectable paths and supervision timing intervals.) Selectable Path I Description Supervision Times — 2010 GSM 2010 IP Single Path (cellular only) Single Path (IP only) 5 minutes 5 minutes 2010 IP & GSM Dust Path (IP and cellular) 24 hours 2013 GSM Single Path (cellular only) 1 hour 1 hour 2013 IP Single Path (IP only) 2013 IP & GSM Dual Path (IP and cellular) 6 hours Features Saves the cost of two dedicated phone lines, Single or dual path communications. (Can communicate to central station using cellular technology, internet or both. Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Honeywell • Multi -GSM platform compatibility for 2G, 3G and 40 net- works, • Operates over the following communication protocols: HSPA+ (4G) HSPA (HISDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). • Selectable reporting paths and supervision Intervals to meet NFRA 72, chapter 26 requirements. (Compliant with NFPA 72 2010 and 2013 supervision requirements.) • Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL modern or cable modem. • Data transmits over standard contact -ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). • Supports both dynamic (DHCP) or Public and Private Static IP addressing. • Built -In Power Supply module: On board charging circuit design accommodates back-up battery, Includes primary power and battery supervision. • Diagnostic LEDs: Signal strength and status indicators. • Reliable connection: IP and GSM connection tested every day. • QOS: Quality of Service diagnostics via AlarmNet convoys vital communicator information Including when message was received, signal strength, and message path used. • 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the off -hook condition and provides the fire panel with a dial tone- When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss -off after the report is successfully received from the fire panal. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on -hook. The IPGSM communica- lions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration), R %, VVZ L. ECEI M A R­ 0 6' 2 017 DEVELOPMENT SERVICES COUNTER Easy to Program The IPGSM-4G communicator can be pre-programmed using the 7720P programmer to enter all central-slation information. This is saved to the 1PGSM-4G communicator panel memory. When the IPGSM-4G communicator is installed at the site and connected to the Internetlintranet, if registers itself with the AlarmNet receiver. .For most installations, the only required parameters are: • Primary City ID (two digits) obtained from your monitoring station. • Primary Central Station ID (two digits) obtained from your monitoring station. • Primary Subscriber ID (four digits) obtained from your mon- itoring station, • Communication Module's MAC ID, and MAC CRC number located on outside of box, and inside of the modula. All of these parameters are assigned by the monitoring station. NOTE. Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Fire Communicator Capability The IPGSM-4G is compatible with fire panels that use the Contact ID communications formal as described in the SIA DC-05 standard. Alarmlillet Honeywell's AlarmNet has been the nationwide leader in alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides exiensive coverage in the United States and Canada. AlarmNel Network Control center processes signals from pow- erful servers in multiple locations equipped with 2417 inffa- structure support. The AlarmNot network consist of redundant hardware servers, hot back -kip databases and generators with battery back-up at all locations to ensure continuity of service Signals from Alarm -Not are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll -free POTS service. Installation Requirements UL COMPUANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: — Primary 120VAC, 60Hz, 0.5A. — Secondary: 18VDC, 50VA. Battery: — One 12 V 7.0 AH lead -acid battery (not supplied). — Battery charging current: 1 Amp maximum. — Battery discharge current: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875- H x 12.75- W x 3.0" D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6-94 kg). Dimensions: 15.625" H X 13.79- W x 9.25" 0 (39.7 crn H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49'C/32 - 120'F and at a relative humidity 93% * 2% RH (non condensing at 321C * 2'C (907 ± 3'F). However. the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore. it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27'C/60 - 801F. Product Line Information IPGSM-4G-. Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with Ademco key and lock. wall outlet box, Dialer Capture Module, IGSM Communications Module, antenna & mounting adapter, PowerBoostl power supply, LED display board, transformer, manual, & required screws, cables, etc. Antenna Kits GSM-ANT3DB25KT: 25 ft. antenna kit. Includes GSM-ANTSDB, WA7626-CA adapter cable, and a 25' RF cable. Q8M-ANT3DB50KT: 60 ft. antenna kit. Includes GSM-ANT3DB, VVA7626-CA adapter cable, and a 50'RF cable. Antonno-ExIffirrial-haltdware GSM-ANT3DO: 3db gain external/remote antenna. WA7626-CA: SNA to N Adapter, 7626-SOHC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. NOTE., The GSM-AIYT3DB and the WA7626-CA are both required lbr installing an oxternal antenna along Mth the necessary cable noedod (7626-50HC. 50 ft. or 76P6-PSHC; 25 ft.) QIftqLA90AM1941 7720P: IPGSM40 hand held programmer. HPTCOVER: Plug in transformer box for 1PGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UIL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. Page 2 of 3 — DH-60769:B - 3/25/13 www.honeywell.com This document Is not intended to be used [or installation purposes. We try to keep our product Information up-to-date and accurate. We cannot coverall spKlrtc applications or anticipate all requirements. All spedfications are subject to change without notice. C2014 by Honeywell International Inc. All rights reserved, Unauthodzed use of this document is strictly prohibited. Automation and Control Solutions Honoywell 12 Clintonville Road 1(877) HPP-POWR Norlhford, CT 06472-1610 www.honeywelipower.com hppjechserv@honeywell.00m DH-60769:8 April 2014 Made In the U.3A OUSIRegistersdIrradam!rk IS9100 02014HonoyWellInternational m. Page 3 of 3 INAUTY 113TIMS Honeywell