20170321105026.pdfRESPONSES TO PLAN REVIEW COMMENT TECHCRAFT CORPORATION RESUB 2126 NW 204" St, Shoreline, WA 98177 MAR 2 1 2017 Tele: 206-817-6081 Email: david6081(d,)qrnail.com BUILDING DEPARTMENT CITY OF EDMONDS Chuck Miller, Plans Examiner: City of Edmonds Plan Examiners Mr. Chuck Miller, Plans Examiner 43LD-Z01-7-00-3-2 Date: 3/8/2017 RE: Plan Check: Bt-020IS--0497 Project Address: 23805 Highway 99, Suite 101 Project: Sizzle Steak House Scope: Tenant improvement for restaurant — A-2 occupancy group — 173 occupants — V- B construction - NFPA-13 sprinkler system required— mechanical, plumbing, type I hood, fire suppression for hood, fire sprinkler, fire alarm, etc. under separate permits Mr. Chuck Miller: The following are our responses to your plan review comments dated as 1/27/2017. All revisions are marked with cloud on revision plan. On sheet PI — Water Supply: 1. Plumbing Water Supply Plan a. Clarify on the plans the difference in the indicated water supply fixture units (WSFU) for all of the branches and of that determined using Uniform Plumbing Code (UPC) Table 610.3. Fixtures having both hot and cold connections typically have a reduced value for each per 'Note 3'. RESPONSE. Revised all on plan and calculations to use this rate. b. Clarify on the plans the difference in the specified diameter of the cold water branch serving the restrooms and of that determined using UPC Table 610-4. RESPOAi 5L, it shall be Y4' pipe. Revised on plan. c. Clarify on the plans the difference in the specified diameter of the cold water branch serving the hot water tank and the south side of the 'Kitchen' and of that determined using UPC Table 610.4. The total demand of hot water supplied by the water heater does not appear to have been accounted for. R,'--'-'PONSE: revise and corrected. -1 i� ank you for your instruction, d. Clarify on the plans the difference in the specified diameter of the 'domestic water supply' and of that determined using UPC Table 610.4. Rf`-"�'PONSE, revised by recalculated value. 2. Legend and Notes a. Add to the plans the 'fixture item number per equipment schedule on architectural plan' to each of the represented fixtures and to the 'Potable Water Delivery Sizing' table, or eliminate the note from the plans. Ri':,.'.IPOt',.I."E.*,,1'(,Ieted from the notes. b. Change on the plans the UPC table reference regarding the water supply sizing from '6-6' to '610.3 & 610.4' c. Change on the plans the UPC section regarding materials for building supply and water distribution piping and fittings from '603' to '604' and the table reference from '14-l' to '604. 1'. R,' E: co, cted. d. Change on the plans the UPC section regarding potable water supply to carbonators from '603.4.12' to '603.5.12'. RESPON.SE. corrected. 3. Potable Water Delivery Sizing table - Change on the plans the number of 'hand sinks' from W to 'T and the associated WSFU from '8' to V. Rf�. I.-*PONSE corrected. On sheet P2 — Drainage Plan: 4. Drainage Fixture Schedule and Sizing a. Note — Add to the plans the 'fixture item number per equipment schedule on architectural plan' to each of the represented fixtures and to the 'Drainage Fixture Schedule and Sizing' table, or eliminate the note from the plans. RFI I�POPI.,.:E. removed this note. b. Note - Change on the plans the UPC table reference regarding minimum trap and trap arm size from 7-3' to '702.1'. Rl' 5PON-I�E: co;-rected. c. Note - Change on the plans the UPC table reference regarding the sizing of drainage and vent piping from 7-5' to '703.2'. X.--l"PONSE: corrected. K S. Grease Trap Sizing - Note - Change on the plans the UPC table reference regarding minimum trap and trap arm size from '7-3' to '702.1' and from '10.2' to '1002.2'. 6. Sewer Waste Diagram a. Clarify on the plans the difference in the indicated drainage fixture units (DFU) for all of the branches and of that determined using UPC Table 702.1, 'Assembly' use. R:�- "'POi,.; " E. coj -n. cted. b. Clarify on the plans the difference in the specified diameter of the waste serving the floor drain and the floor sink serving the 'Dishwasher' and the 'sanitize' portion of the 3- compartment sink, and of that determined using UPC Table 703.2. RESPO,'.1'.',E: coi-rccted. 7. Vent Riser Diagram a. Clarify on the plans the difference in the indicated DFU for all of the branches and of that determined using UPC Table 702.1, 'Assembly' use. Ri.-"-POA!-')-E, corrected, b. Clarify on the plans the difference in the number of the represented 'floor drains' and of that noted on the 'Drainage Fixture Schedule and Sizing' and the 'Sewer Waste Diagram'. Ri'-,-, PO)',: -E: corrected. c. Clarify on the plans the difference in the specified diameter of the vent serving the restrooms and the portion of the 'Kitchen' before the 'Dishwasher', and of that determined using UPC Table 703.2. Ri .--)PONSE: (Wrected. d. Clarify on the plans the difference in the specified diameter of the waste serving the restrooms and the 'Kitchen' before the 'Bar', and of that determined using UPC Table 703.2. R, �IPOjV -�E: coi i, -cted. 8. Sewer Waste and Vent Riser Diagram a. Notes - Change on the plans the UPC table reference regarding the drainage fixture units and traps from 7-3' to '702.1'. RI'.,';POj',!'�'E: coi rected. b. Notes - Change on the plans the UPC table reference regarding minimum trap and trap arm size from 7-3' to '702.1'. RESPONSE. corrected, c. Notes - Change on the plans the UPC table reference regarding the sizing of drainage and vent piping from '7-5'to '703.2'. R",)PONSE: corrected, Should you have any questions and concern, please contact me as your convenient: My cell phone 206-817-6081, Email: david6081((Dgmail.com . Sincerely, David Lee Techcraft Corp.