20170321105026.pdfRESPONSES TO PLAN REVIEW COMMENT
TECHCRAFT CORPORATION RESUB
2126 NW 204" St, Shoreline, WA 98177 MAR 2 1 2017
Tele: 206-817-6081
Email: david6081(d,)qrnail.com BUILDING DEPARTMENT
CITY OF EDMONDS
Chuck Miller, Plans Examiner:
City of Edmonds Plan Examiners
Mr. Chuck Miller, Plans Examiner
43LD-Z01-7-00-3-2 Date: 3/8/2017
RE: Plan Check: Bt-020IS--0497
Project Address: 23805 Highway 99, Suite 101
Project: Sizzle Steak House
Scope: Tenant improvement for restaurant — A-2 occupancy group — 173 occupants — V-
B construction - NFPA-13 sprinkler system required— mechanical, plumbing, type I hood,
fire suppression for hood, fire sprinkler, fire alarm, etc. under separate permits
Mr. Chuck Miller:
The following are our responses to your plan review comments dated as 1/27/2017. All
revisions are marked with cloud on revision plan.
On sheet PI — Water Supply:
1. Plumbing Water Supply Plan
a. Clarify on the plans the difference in the indicated water supply fixture units (WSFU) for all of
the branches and of that determined using Uniform Plumbing Code (UPC) Table 610.3. Fixtures
having both hot and cold connections typically have a reduced value for each per 'Note 3'.
RESPONSE. Revised all on plan and calculations to use this rate.
b. Clarify on the plans the difference in the specified diameter of the cold water branch serving
the restrooms and of that determined using UPC Table 610-4.
RESPOAi 5L, it shall be Y4' pipe. Revised on plan.
c. Clarify on the plans the difference in the specified diameter of the cold water branch serving
the hot water tank and the south side of the 'Kitchen' and of that determined using UPC Table
610.4. The total demand of hot water supplied by the water heater does not appear to have
been accounted for.
R,'--'-'PONSE: revise and corrected. -1 i� ank you for your instruction,
d. Clarify on the plans the difference in the specified diameter of the 'domestic water supply'
and of that determined using UPC Table 610.4.
Rf`-"�'PONSE, revised by recalculated value.
2. Legend and Notes
a. Add to the plans the 'fixture item number per equipment schedule on architectural plan' to
each of the represented fixtures and to the 'Potable Water Delivery Sizing' table, or eliminate
the note from the plans.
Ri':,.'.IPOt',.I."E.*,,1'(,Ieted from the notes.
b. Change on the plans the UPC table reference regarding the water supply sizing from '6-6' to
'610.3 & 610.4'
c. Change on the plans the UPC section regarding materials for building supply and water
distribution piping and fittings from '603' to '604' and the table reference from '14-l' to
'604. 1'.
R,' E: co, cted.
d. Change on the plans the UPC section regarding potable water supply to carbonators from
'603.4.12' to '603.5.12'.
RESPON.SE. corrected.
3. Potable Water Delivery Sizing table - Change on the plans the number of 'hand sinks' from
W to 'T and the associated WSFU from '8' to V.
Rf�. I.-*PONSE corrected.
On sheet P2 — Drainage Plan:
4. Drainage Fixture Schedule and Sizing
a. Note — Add to the plans the 'fixture item number per equipment schedule on architectural
plan' to each of the represented fixtures and to the 'Drainage Fixture Schedule and Sizing'
table, or eliminate the note from the plans.
RFI I�POPI.,.:E. removed this note.
b. Note - Change on the plans the UPC table reference regarding minimum trap and trap arm
size from 7-3' to '702.1'.
Rl' 5PON-I�E: co;-rected.
c. Note - Change on the plans the UPC table reference regarding the sizing of drainage and vent
piping from 7-5' to '703.2'.
X.--l"PONSE: corrected.
K
S. Grease Trap Sizing - Note - Change on the plans the UPC table reference regarding minimum
trap and trap arm size from '7-3' to '702.1' and from '10.2' to '1002.2'.
6. Sewer Waste Diagram
a. Clarify on the plans the difference in the indicated drainage fixture units (DFU) for all of the
branches and of that determined using UPC Table 702.1, 'Assembly' use.
R:�- "'POi,.; " E. coj -n. cted.
b. Clarify on the plans the difference in the specified diameter of the waste serving the floor
drain and the floor sink serving the 'Dishwasher' and the 'sanitize' portion of the 3-
compartment sink, and of that determined using UPC Table 703.2.
RESPO,'.1'.',E: coi-rccted.
7. Vent Riser Diagram
a. Clarify on the plans the difference in the indicated DFU for all of the branches and of that
determined using UPC Table 702.1, 'Assembly' use.
Ri.-"-POA!-')-E, corrected,
b. Clarify on the plans the difference in the number of the represented 'floor drains' and of that
noted on the 'Drainage Fixture Schedule and Sizing' and the 'Sewer Waste Diagram'.
Ri'-,-, PO)',: -E: corrected.
c. Clarify on the plans the difference in the specified diameter of the vent serving the
restrooms and the portion of the 'Kitchen' before the 'Dishwasher', and of that determined
using UPC Table 703.2.
Ri .--)PONSE: (Wrected.
d. Clarify on the plans the difference in the specified diameter of the waste serving the
restrooms and the 'Kitchen' before the 'Bar', and of that determined using UPC Table 703.2.
R, �IPOjV -�E: coi i, -cted.
8. Sewer Waste and Vent Riser Diagram
a. Notes - Change on the plans the UPC table reference regarding the drainage fixture units and
traps from 7-3' to '702.1'.
RI'.,';POj',!'�'E: coi rected.
b. Notes - Change on the plans the UPC table reference regarding minimum trap and trap arm
size from 7-3' to '702.1'.
RESPONSE. corrected,
c. Notes - Change on the plans the UPC table reference regarding the sizing of drainage and
vent piping from '7-5'to '703.2'.
R",)PONSE: corrected,
Should you have any questions and concern, please contact me as your convenient: My
cell phone 206-817-6081, Email: david6081((Dgmail.com .
Sincerely,
David Lee
Techcraft Corp.