20170327101625.pdfWater Residential Electric
Professional Classic Water Heaters
The new degree of comfort"
Professional Classic" electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
* .95 EF
* Isolated tank design reduces
conductive heat loss
* Resistored copper upper element and
resistored Lifeguard'" stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 42 - 71 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 90' F rise
System Sentinel
(Available on selected models)
Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
EverKleen" self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank life
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured housing
and modular construction
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty*
• With Protection Plus" the 6-year limited
tank warranty becomes 1 0-year
*See Residential Warranty Certfficate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to the AHRI Operations
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
Professional Classic
19.9 to 55-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
1@10=11
See specifications chart on back.
PRINTED IN U S A 12/16 WP FORM NO PROE RH N Rw. 4
0
The now dogree of comfort7
Professional Classic"I" Specifications
Water � Residential Electric
Professional Classic Water Heaters
DESCRIPTION
MODEL
.1
TYPEJOCAALP. NUMBER
FEATURES
FIRST HOUR RECO RY
RAT P.H.
ING ING7
G.P.H. GD- F RISE
ROUGHING IN DIMENSIONS (SHOWN IN CHES)
ENERGYINFO.
TANK
HEIGHT
A
HEIGHT TO
WATER CONN.
B
DIAMETER
C
APPROX.
SHIP Wr.
(LBS)
ENERGY
FACTOR
Taill
30
PROE30 T2 RH951
48
21
47-1/2
50-3/8
19-1/4
92
0.95
Tell
40
PROE40 T2 FIH951
57
21
60-3/4
63-5/8
19-114
109
0.95
Tall
50
PROE50 T2 RH951
67
21
58-5/8
61-5/8
20-1/4
121
0.95
Tal
55
PROE55 T2 RH941
71
21
57
59-3/4
22-1/4
128
0.94
Mad.
30
PROE30 M2 RH95r
44
21
37-1/2
40-1/2
20-1/4
92
0.95
Mod.
40
PROE40 M2 RH95t
55
21
48-1/4
50-1/2
20-1/4
1 106
0.95
Med.
50
PROE50 M2 RH95t
65
21
48
50-1/2
23
132
0.95
Short
102
PROE20 S2 RH
-
21
31-1/2
31-1/2
17
62
-
Short
_28
PROE28 S2 RH95
42
21
30
31-1/8
23
95
0.95
Short
30
PROE30 S2 RH95 B"
42
21
30-1/8
32
19-3/4
95
0.95
Short
36
PROE36 S2 RH95
45
21
31-1/2
33
24-1/4
118
0.95
J$hortj
30
1 PROE38 S2 RH9513-
55
21
31-1/2
3 _�/8
1 23
108
0.95
IShedl
47
1 PROE47 S2 RH95 B"
55
21
32
34
1 26-1/4
149
0.95
Energy Factor based on D.O.E. (Department of Energy) test procedures.
System Sentinel optional. Add ECII to the end of the model number. System Sentinel not available on single
element models, available on dual element models only. System Sentinel not available in excess of 5 IkW on
208 V models.
Water heater dimensions prior to installing insulation blanket that is included with water heater.
Heaters furnished with standard 240 volt AC. single phase non -simultaneous wiring. and 4500 watt upper and lower boating
elements.
If heating elements of different wattages than those shown are demanded by zone requirements, they must be
specifically requested.
Single element models available on special order (600OW max.). Substitute "l " for"T In model number.
Special Wiring Options -A limited number of special Wring options are avallable. Consult factory for price and availability.
All models equIpped with heat traps.
1 Recovery = wattage/2.42 x temp. rise
Example: 450OW = 21 GPH
2.42 x 90'
Recovery calculations used are based on 4500 watt elements ussd in non-simuftaneous operation.
HOT
WATER
0
COLD
CONNECTION
_�MANODE
WATER
RELIEF VALVE
CONNECTION
CONNECTION
ROD
.*— C
I DIAMETER I
B ,
WATER CONNECTIONS ALL a/4" N.P.T.
In keeping with its policy of continuous progress and product improvement, Pheem reserves the right to make changes without notice. —71
Rheem Water Heating - 101 Bell Road
Montgomery, Alabama 36117-4305 - www.rheem.com
PRINTED IN U.S.A. 12/16 WP FORM NO. PROE RH N Re% 4