Loading...
2017-04-10 Magic Toyota Edmonds_Permit Set - plumb.pdfA AI%COMPRESSED AIR ABS AC YLONITRITE BUTADIENE STYRENE ABV ABOVE AC AIR COMPRESSOR AD ACCESS D00%AREA DRAIN/AIR DRYER ADD/ADD'L ADDITION ADDI IONAL I ADJ ADJACEN�,/ADJUST/ADJUSTABLE/ADJUSTMENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AP ACCESS PANEL ARCH ARCHITECT ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ATM ATMOSPH ERE/ATMOSPH ERIC BHP BRAKE HORSEPOWER/BOILER HORSEPOWER BLDG BUILDING BOP BOTTOM OF PIPE BOT BOTTOM BS BLACK STEEL BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR COND CONDENSATE CA COMPRESSED AIR C TO C CENTER TO CENTER CAP CAPACITY/END CAP CB CATCH BASIN CENT CENTRIFUGE/CENTRIFUGAL CFF CAP FOR FUTURE CFM CUBIC FEET PER MINUTE CI CAST IRON CLG CEILING CMU CONCRETE MASONRY UNIT CO CLEANOUT�COMPANVCARBON MONOXIDE CO2 CARBON IOXIDE COL COLUMN CONC CONCRETE COND CONDENSATE CONN CONNE&CONNECTEDYCONNECTION CONT t A CONTINU US/CONTIN ATION CONTR CONTRACTOR COORD COORDINATE CPVC CHLORINATED POLYVINYL CHLORIDE CT COOLING TOWER CU CUBIC/COPPER CONDENSING UNIT CW DOMESTIC COY WATER DCVA DOUBLE CHECK VALVE ASSEMBLY DDC DIRECT DIGITAL CONTROL DEG DEGREE/DEGREES DI DEIONIZED WATER DIA DIAMETER DIFF DIFFERENTIAL/DIFFERENCE/DELTA DISCH DISCHARGE DN DOWN DOM DOMESTIC DR DRAIN DS DOWNSPOUT DWG DRAWING DWV DRAIN, WASTE AND VENT EA EACH EFF EFFICIENCY EL ELEVATION ELEC�ELECT ELECTRICAL/ELECTRIC EMER EMERGENCY ENT ENTERING EQUIP EQUIPMENT ERW ELECTRIC RESISTANCE WELDED ES EMERGENCY SHOWER ET EXPANSION TANK EWC ELECTRIC WATER COOLER(I EVAPORATIVE WATER COO ER EWT ENTERING WATER TEMPERATURE EXIST EXISTING EXP EXPANSION EXPOSED/EXPLOSION PROOF EXT EXTERNAL EXTERIOR F FAHRE H IT FEED/FILTER FA FACE FIRE ALARM FCO FLOOR C%LN OUT FD FLOOR DRAIN FDN FOUNDATION FF FINISH FLOOR FFD FUNNEL FLOOR DRAIN FIC FURNISHED AND INSTALLED BY CONTRACTOR FIO FURNISHED AND INSTALLED BY OWNER FLEX FLEXIBLE FLR FLOOR FOIC FURNISHED BY OWNER INSTALLED BY OTHERS FP FREEZE PROOF/FIRE PROTECTION FPM FEET PER MINUTE FPS FEET PER SECOND FPWH FREEZE PROOF WALL HYDRANT FS FLOOR SINK, FLOW SWITCH FT FOOT/FEET GA(GAL GALLON GA V GALVANIZED GD GARAGE DRAINYGARBAGE DISPOSAL GC F GENERAL CON RACTOR GEN GENERAL GND GROUND GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HB HOSE BIBB HD HEAD HDR HEADER HG MERCURY HORIZ HORIZONTAL HOA HAND -OFF -AUTOMATIC HIP HORSEPOWER HR HOUR HT HEIGHT/HEAT TRACE HW DOMESTIC HOT WATER HWC DOMESTIC HOT WATER CIRCULATING HX HEAT EXCHANGER HZ HERTZ IA INSTRUMENT AIR IBC INTERNATIONAL BUILDING CODE ICW INDUSTRIAL COLD WATER ID INSIDE DIAMETE%DIMENSION IE INVERT ELEVATIO IN INCH(INCHES IN WG INCH S WATER GAUGE INV INVERT IRW IRRIGATION WATER 1W INDIRECT WASTE KWH KILOWATT HOUR KEC KITCHEN EQUIPMENT CONTRACTOR LAV LAVATORY LB/LBS POUND/POUNDS LBS/HR POUNDS PER HOUR LPG LIQUID PROPANE GAS LIPS LOW PRESSURE STEAM LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH 1000 BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM� MINUTE MISC t MISCEL NEOUS MM MILLIMETERS MPS MEDIUM PRESSURE STEAM MTD MOUNTED N NITROGEN NA NOT APPLICABLE NC NORMALLY CLOSED/ NOISE CRITERIA NG NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN/ NUMBER NO2 NITROUS OXIDE NOM NOMINAL NP NON -POTABLE NTS NOT TO SCALE 02 OXYGEN OC ON CENTER OD OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN ODP OPEN DRIPPROOF ORD OVERFLOW ROOF DRAIN OVHD OVERHEAD PD PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE PERF PERFORATED PH PHASE PLBG PLUMBING POC POINT OF CONNECTION PRESS PRESSURE PRV PRESSURE REDUCING VALVE PS PRESSURE SWITCH PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PVC POLYVINYL CHLORIDE QTY QUANTITY R RISER / RETURN RCVR RECEIVER RD ROOF DRAIN/ REFRIGERANT DISCHARGE RECIRC RECIRCULATING/ RECIRCULATE RED REDUCE/ REDUCING REF REFERENCE REG REGULATOR RL RAIN LEADER/ REFRIGERANT LIQUID RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION RV RELIEF VALVE RVD RELIEF VALVE DISCHARGE S SOIL/ SUPPLY SAN SANITARY SAT SATURATION SD STORM DRAIN S-C SEATTLE --- CODE SECT SECTION so SCREENED OPENING SOL SOLENOID SOLV SOLENOID VALVE SID STATIC PRESSURE/ SPRINKLER SPEC SPECIFICATION SQ SQUARE SQ FT SQUARE FEET SS SANITARY SEWER STRUC STRUCTURAL SUCT SUCTION TBD TO BE DETERMINED TD TEMPERATURE DIFFERENTIAL TEMP TEMPERATUR TEMPORARY THERM THERMOMETE TOP TOP OF PIPE TP TRAP PRIMER TIPS TRAP SEAL TYP TYPICAL UG UNDERGROUND UNO UNLESS NOTED OTHERWISE UPC UNIFORM PLUMBING CODE UR URINAL UTIL UTILITY V VENT/ VOLT VA VALVE/ VOLT AMPERE/ VACUUM AIR VAC VOLTS ALTERNATING CURRENT/ VACUUM VB VACUUM BREAKER VEL VELOCITY/ VERIFY EXACT LOCATION VERT VERTICAL VOL VOLUME VR VENT RISER VTR VENT THROUGH ROOF W WASTE/ WIDTH/ WATT W/ WITH W/O WITHOUT WAGD WASTE ANESTHESIA GAS DISPOSAL WC WATER CLOSET WCO WALL CLEANOUT WH WALL HYDRANT/ WATER HEATER/ WATT HOUR WILD WELDED WM WATER METER WO WASTE OIL WIP WATERPROOF/ WEATHERPROOF WR WASTE RISER WT WATERTIGHWT WEIGHT WWP A WORKING ATER PRESSURE 0 ELBOW UP D ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN REDUCER TEE OUTLET UP TEE OUTLET DOWN UNION PIPE ANCHOR EXPANSION JOINT kly STRAINER WITH BLOWDOWN VALVE .1 GATE VALVE GLOBE VALVE BALL VALVE CHECK VALVE ......... ... PRESSURE REDUCING VALVE FLOW BALANCING VALVE (AUTO OR MANUAL) T&P RELIEF VALVE GAS COCK LINE CLEANOUT PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION PLUG OR CAP WATER HAMMER ARRESTOR BUTTERFLY VALVE SOLENOID VALVE BACKFILOW PREVENTER REDUCED PRESSURE BACKFLOW PREVENTER METER METER ZUR sm., I - EXISTING PIPING 01 DEMO PIPING WASTE - - - - - - - - - VENT DOMESTIC HOT WATER- RECI RCU LATI NG DOMESTIC HOT WATER DOMESTIC COLD WATER GRW GREASE WASTE SD STORM DRAIN OSD OVERFLOW STORM DRAIN NPCW/NPHw- NON -POTABLE COLD/HOT WATER DI DEIONIZED WATER WAGD WASTE ANESTHESIA GAS DISPOSAL CA COMPRESSED AIR CO2 CARBON DIOXIDE N2 NITROGEN NO2 NITROUS OXIDE 02 OXYGEN MA MEDICAL AIR MV MEDICAL VACUUM MPSW MEDIUM PRESSURE STEAM SUPPLY MPR(#) MEDIUM PRESSURE STEAM CONDENSATE RETURN LPS(#) LOW PRESSURE STEAM SUPPLY LPR(#) LOW PRESSURE STEAM CONDENSATE RETURN COND CONDENSATE 0 FLOOR CLEANOUT 19 FLOOR DRAIN / SINK PUMP 0 ROOF DRAIN OR OVERFLOW DRAIN PLUMBING FIXTURES PLUMBING FIXTURE DESIGNATION POINT OF CONNECTION RISER DESIGNATION PLUMBING EQUIPMENT DESIGNATION &_ DRAWING (CIRCLE NOTE) REFERENCE PLUMBING / PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC, 2015 IMC & 2005 SEATTLE BOILER AND PRESSURE VESSEL CODE WITH WASHINGTON STATE AMENDMENTS. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. I 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHORITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 16. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 11" TALL PAN WHERE INSTALLED ABOVE A CEILING. 18. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 19. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 20. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT J" PER FOOT UNLESS OTHERWISE NOTED. 21. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION PO.00 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX - PLUMBING PO.01 SCHEDULE SHEET - PLUMBING PO.02 SCHEDULE SHEET - PLUMBING P2.00 FOUNDA11ON PLAN PLUMBING P2.01 1ST FLOOR PLAN PLUMBING P2.02 2ND FLOOR PLAN PLUMBING P2.R1 ROOF PLAN - PLUMBING P5.01 DETAIL SHEET - PLUMBING FTI W 0 of 1 off NE 1/4 OF THE NW 1/4 SECTION 29, TOWNSHIP 27N RANGE E4, W.M. VICINITY MAP NO SCALE SITE MAP NO SCALE MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN OPERATING TEMPOF INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) CONDUCTIVITY RANGE MEAN TEMP RATING OF <1 1 TO <1-1/2 1-1/2 TO T <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 029-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0�29 125 1.5 1 1' 5 10 2.0 1 2.0 105-140 .28 0.21-0 �9 + 100 1 1.0 1 1.0 1 1.5 1 .5 1 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 1 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)" 40-60 0.21-0.27 75 1 0.5 0.5 1.0 TO 1.0 <40 020-0.26 75 1 0.5 + 1.0 1.0 1.0 1.5 111 A C 0 IX M1 ACO NOTE: NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ISSUE FOR PERMIT TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED AND SEE R403 FOR RESIDENTIAL INSTALLATIONS. Hermanson ftilding Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 �,ODOR 41, 0�, WAS,,tj, rl GIS 10 IV;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3_ 03/24/17 DWN COORD SET REV2 - 03/17/17 DWN COORD SET REV1_ 03/02/17 DWN DD SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11-17-10152 Issue Date 04/12/17 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX - PLUMBING POM00 INSUL INSULATE/INSULATION ELECTRIC WATER HEATER SCHEDULE LAST UPDATED: 3/22/2017 STORAGE RECOVERY UNIT BASIS CAPACITY EWT LWT RATE ELEC WEIGHT TAG LOCATION SERVES DESIGN MODEL TY PE GALLONS OF OF GPH KW V/PH LBS REMARKS EWH-1 1ST FLR RESTRIM MAIN OFFICE AO SMITH DRE-52 TANK 50 50 120 52.7 9 480/3 680 1,2,3,7 EWH-2 TOOL RM WASH/DETAIL AO SMITH DRE-120 TANK 119 50 120 52.7 9 480/3 1378 1,2,3,7 I I I I I I I I I I I I I I 1 POWER WIRING AND DISCONNECT (BY ELECTRICAL CONTRACTOR) 2 PIPE RELIEF VALVE TO NEAREST FLOOR DRAIN OR HUBDRAIN AT SINK WITH INDIRECT TERMINATION 3 DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 4 120V RECEPTACLE REQUIRED FOR PLUG IN CONNECTION BY ELECTRICAL CONTRACTOR 5 150 PSI OPERATING PRESSURE - MOUNT IN CABINET SPACE BELOW SINK. 6 120V HARD WIRED CONNECTION BY ELECTRICAL CONTRACTOR 7 DRAIN PAN TO BE PIPED TO INDIRECT CONNECTION AT FLOOR DRAIN, WALL BOX, MOP SINK, OR AIR GAP FITTING HOT WATER CIRCULATION PU.M..P SCHEDULE LAST UPDATED: 03/14/17 : --------------- A REA-Em— SERV ED 11, BASIS OF DESIGN OPER. HEAD FTH20 SHUT-OFF HEAD FT H20 'TIO '.-ORSTR#C 11 PRESS. PSI ��Rrkffrerz ME 1 STA9TE9. DISCO1J1JEAt!1fWD TIVE9, FUTE9LOC"TITIJG BY ELE1*_9,IC4,L C8'UT9,kWOP. 2 STAINLESS STEEL CONSTRUCTION. PROVIDE WITH AUTOMATIC TIMER EXPANSION TANK SCHEDULE LAST UPDATED: 02/28/17 UNIT TAG LOCATION SERVES BASIS OF DESIGN TYPE POSITION DIA INCHES HEIGHT INCHES CAPACITY GALLONS ACCEPTANCE GALLONS MIN TEMP (OF) MAX TEMP (OF) PRESS RATING (PSI) WEIGHT LBS, REMARKS Ei 2ND FLR JAN EWH-1 AMTROL ST-5 BLADDER VERTICAL 8.0 12.0 2 1 50 120 125 35 1 Ei FIRE RISER RM EWH-2 AMTROL ST-5 BLADDER VERTICAL 8.0 12.0 2 1 50 120 125 35 1 1 1 'Eur"I on PLUMBING FIXTURE CONNECTION SCHEDULE LAST UPDATED 3/2/17 MANUFACTURER AND MODEL NUMBER WATER CLOSET (ADA) WALL MOUNT, SENSOR FLUSH VALVE KOHLER K-4325, K-10956-CP FLUSH VALVE WATER CLOSET (ADA) FLOOR MOUNT FLUSH VALVE KOHLER K-4405, SLOAN ROYAL 111-1.28 URINAL (ADA) WALL MOUNT SENSOR FLUSH VALVE KOHLER K-4904, K-10949-CP FLUSH VALVE LAVATORY (ADA) KOHLER K-2215, 23 X 16, DYSON AB09 SHORT LAVATORY (ADA) KOHLER K-1999-1-0 LAV & SHROUD, CHICAGO EQ-Dl2A-13ABCP KITCHEN SINK (ADA) S.S. DOUBLE COMPARTMENT, COUNTERTOP ELKAY LRADQ-3319-55-3, 18 GA. SS, 33X19, DELTA 100-WIF-12" FAUCET SINGLE COMP. SINK (ADA) S.S. SINGLE COMPARTMENT, COUNTERTOP ELKAY LRADQ-2219-55-3, 18 GA. SS, 22X19, DELTA 100-WIF-8" FAUCET IFINOTOR mm"k FLOOR MOUNT, CORNER PROFLO PFMB 2424, 24X24, FIAT 830AA SERVICE FAUCET DRINKING FOUNTAIN (ADA) INDOOR WALL MOUNT - DUAL HEIGHT ELKAYEZH20 MODEL LZSTL8WSLK (DRINKING FOUNTAIN WTH BOTTLEFILLING STATION) so . . LOOSE KEY HANDLE, MALE HOSE THREAD OUTLET WOODFORD 22, SILLCOCK WITH VACUUM BREAKER, CHROME PLATED WALL HYDRANT EXTERIOR NON -FREEZE, WALL HYDRANT, CHROME WOODFORD 65C, VACUUM BREAKER NICKEL BRONZE, ROUND ADJUSTABLE STRAINER JR SMITH 2005-A FUNNEL FLOOR DRAIN NICKEL BRONZE, ADJUSTABLE STRAINER JR SMITH 2005-A WITH 3591 FUNNEL INTIT-307TIM DRAIN INSERT (NO TRAP PRIMER) JR SMITH 2692 TRENCH DRAIN JR SMITH 9930-GHD-1,�V TRENCH DRAIN LTivsto 0 111cf-3 JR SMITH 9930-GHD-25'-8" TRENCH DRAIN PRE -SLOPED POLYPRO WITH GALV SLOTTED GRATE JR SMITH 9930-GHD-32'-3" TRENCH DRAIN JR SMITH 9930-GHD-51-6" TRENCH DRAIN LTivsto 0 111cf-3 JR SMITH 9930-GHD-52' FLOOR CLEANOUT CI TOP, BRONZE OR ABS PLUG, ADJUSTABLE JR SMITH 4224LXH04 WALL CLEAN OUT CAST IRON TEE, SS COVER, CI OR ABS PLUG JR SM IT H 4530S 0 RW- CAST IRON DOME STRAINER JR SMITH 1010Y-R-C OVERFLOW ROOF DRAIN CAST IRON DOME STRAINER, WATER DAM JR SMITH 1080Y-R-C THERMOSTATIC MIXING VALVE IN WALL, MOUNTING BRACKET, BRONZE POWERS LFe480 1 WALL CARRIERS: JR SMITH 0700 FOR LAVS, JR SMITH 0630 FOR URINALS, JR SMITH 0200 WATER CLOSETS, WATTS ISCA-141 FOR SINGLE WATER CLOSETS - MOUNTING HEIGHT AS SHOWN ON ARCHITECTURAL DRAWINGS 2 PROVIDE OLSONITE 1OCC ELONGATED SEAT, OPEN FRONT, NO COVER, EXTERNAL CHECK HINGE 3 SIZE CW AT 1 1/4" DOWN TO FIXTURE CONNECTION FOR ALL FLUSH VALVES 4 PROVIDE 1 1/4 17 GA P-TRAP CP, MCGUIRE 155A OPEN GRID PO PLUG , BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CP WITH BRAIDED FLEXIBLE HOSE. 5 PROVIDE TRUEBRO 103 INSULATION FOR P-TRAP AND SUPPI TES PER ADA REQUIREMENTS 6 PROVIDE VACUUM BREAKER, PAIL HOOK, INTEGRAL CHECK STOPS, WALL BRACE, 30" RUBBER HOSE, HOSE HOOK, METAL STRAINER, MOP HANGER W/ GRIPS, STAINLESS STEEL WALL GUARD 7 PROVIDE JUST J-35 SS CUP STRAINER WITH REMOVABLE BASKET, 1 1/2 17 GA P-TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 8 PROVIDE 1 1/4 17 GA P-TRAP 9 FOR NON-FREEZING AREAS ONLY 10 PROVIDE VACUUM BREAKER, 1/4 TURN T-HANDLE KEY 11 PROVIDE TRAP PRIMER, PRECISION PLUMBING PRODUCTS P/N-PO-500 12 WITH GRAVEL GUARD, PROVIDE ROOF SUMP RECEIVER AND UNDERDECK CLAMP IF NEEDED 13 120 VOLT POWER (TO OPERATE WATER SOLENOID) TO DRINKING FOUNTAIN BY ELECTRICAL CONTRACTOR. COORDINATE LOCATION OF ELECTRICAL OUTLET 14 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. PROVIDE WITH EASTMAN AIRGAP FITTING AT SINK 15 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. 16 WATER SERVICE& SHUT OFF BY PLUMBING CONTRACTOR 17 INSTALL IN ACCESIBLE LOCATION OR PROVIDE WALL ACCESS PANEL (BY G.C.) 18 PROVIDE NO SEEP WAX RING, 1/4X2 1/4 STAINLESS T-HANDLE, STAINLESS BNW SET Her,manson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 ,�,ODOR 9 GIS Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3 — A 03/24/17 DWN COORD SET REV2_ 03/17/17 DWN COORD SET REV1- 03/02/17 DWN DID SET No. Date By Description Design Team Design DWN Drawn FVIP Checked DTNI Project Number 11-17-10152 Issue Date 04/12/17 SCHEDULESHEET - PLUMBING P0001 ISSUE FOR PERMIT iREDUCEDPRESSUREBACKFLOW PREVENTER, LAST UPDATED: 03/22/17 BASIS OF DESIGN MODEL # OR TYPE 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD PIPING MATERIAL SCHEDULE 03/01/17 PIPE SERVICE LOCATION F_ MATERIAL JOINT METHOD REMARKS COLD & HOT WATER UNDERGROUND COPPER/L BRAZED UNDERGROUND-,----- PEX-A MECHANICAL JOINT ABOVE GROUND COPPER/L OR M LEAD FREE SOLDER, PRESSFIT, ROLL GROOVED JOINT ...... ABOVE GROUND PEX-A PEX FLARE JOINT PROTECT IF IN RAPLENUM, INCREASE ONE NOMINAL PIPE SIZEO\/ERCOPPER WASTE UNDERGROUND PVC SCH 40 DWV SOLVENT CEMENTED WHERE ALLOWED UNDERGROUND PVC SCH 40 DWV SOLVENT CEMENTED GREASE WASTE (UNDER 1400F) ABOVE GROUND--- CAST IRON NO HUB . ..... ABOVE GROUND PVC SCH 40 DWV_ ---- — - SOLVENT CEMENTED IF NOT IN A RA PLENUM NOTE: BLDG HEIGHT LIMIT DELETED IN 2002 WSBC AMENDS VENT . .......... ALL - - - ---------- ..... . ................. CAST IRON ........................ NO HUB ......... . . ................... .......................... . ..... . . . . ...................... . .... . .......................... . ..... . ..... A-BOVE GROUN-D C­_1'______­' 5 d + PV SCH 40 DWV SOLVENT CEMENTED IF NOT IN A RA PLENUM RAIN LEADERS —ABOVE GROUND CAST IRON NO HUB ABOVE GROUND PVC SCH 40 DWV SOLVENT CEMENTED IF NOT IN A RA PLENUM UNDERGROUND CAST IRON NO HUB OR HUB AND SPIGOT COIL CONDENSATE ABOVE GROUND. PVC SCH 40 —ORM SOLVENT CEMENTED NOT IN A RA PLENUM �_ABOVE GROUND :::::j:::::::::��'P_ER/DWV PRESSFIT OR SOLDI R R REFRIGERANT ALL COPPER ACR BRAZED PROVIDE NITROGEN PURGE ALL COPPER ACR ZOOMLOCK, LOKRING PROVIDE NITROGEN PURGE ALL PRE -INSULATED COPPER LINE SETS BRAZED PROVIDE NITROGEN PURGE WATER HAMMER ARRESTORS LAST UPDATED: 02/28/17 BASIS OF DESIGN SIZE INCHES UNIT FIXTURE RATING WADE SHOPSTOP GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC ... ) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 UNIT APPROVED FOR SEALED WALL INSTALLATION WITHOUT MAINTENANCE. 2 UNIT CONFORMS TO PDI AND A.S.S.E. STANDARDS WATER PRESSURE REDUCING VALVE SCHED LAST UPDATED: 03/22/17 �8111111111!i LOCAT N OA� BASIS OF DESIGN MODEL # OR TYPE I I I TOM reim GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC ... ) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 -c,ODOR WAS,,tj, 0� �GIS S10 N;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3_ 03/24/17 DWN COORD SET REV2 — 03/17/17 DWN COORD SET REV1_ 03/02/17 DWN DD SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11 —17-10152 Issue Date 04/12/17 SCHEDULESHEET - PLUMBING P0002 ISSUE FOR PERMIT E= �4"W 7.65' ------------------- --- --------------- --- --------------- -- --------------- --------- --- --------------- - --------------------- --- ------------------------ --- Uj CL C� Lo 2"W UP -\ TO SINKS 0— IE= 98.75' 4"W UP IN WALL/- 4'V 4"W 0D)-4"W-U1'-TO WALL CLEANOUT 3"W UP TO FLOOR DRAIN 2"V Up A UP TO 2-V UP SINKS 3"W UP TO J FLOOR DRAIN 2"V UP I'll I I 3"W UP TO FLOOR DRAIN ,CE IE: 98.5' 4"W 4"W 2"W UP 2'"V up--/, TO IINKS FL�OUP TO R DRAIN - - - - - - - - - - - - -4 P 4V UP 4V UP TO TO WCO FLOOR CLEANOUT 4HOW Up To L CLEANOUT 4"OW VA VA MA VA 1% SLOPE MA M1% 4"RD UP 4"RD UP 4"RD UP 4"RD UP Up T (2837 SF 02") TO FCO TO FCO 4"R�99 IE= 99.17' IE= .17' ------------ - -- (249-3-SF--@*- ------------ -430i%�-SIF 02�— - So 6 SD IE= 91'8.55� IE= 98.5' IE= 98.5' 4"RD UP TO FCO in Cn I LLJ CL Q- LLJ 2 LLJ U) Q- U) CL 6"RD 6"OW 4"RD (5549 SF 02") (n (2837 SF 02") 4"OW UP TO 4"OW UP TO FLOOR CLEANOUT IE= 97.87' TRENCH DRAIN 4"OW 1 % SLOPE IE= 98.5' IE= 98.24' is ka /is— —ka ks --- Ut v- IE= 98.17' 4-OW UP TO 4"OW IE= 98.5' TRENCH DRAIN T f FLOOR %RA12 SEE STRUCTURAL DWGS 6' 4"RD IE= 98.39 IE= 98.5' 4"RD UP IE= 99.17' (3434 SIF C lE= 98.33' GIENM NOTE. FINAL INVERT ELEVATIONS TO BE COORDINATED WITH CIVIL. FIELD VERIFY CONDITIONS. 6-RD � IE= 97.5' 6"RD FOR SLEEVE THRU 4"RD 6"RD IE= 98.17" FOOTING DETAIL (TYP) IE= 98.10' IE= 97.43' Uj (5549 SF 02') 2'-8" 3"RD UP (2837 SF 02') 5-118 (511 SF 02') 5'-058 J rj� --02 �5 7 4 3 1 9 C7) C�) , �Iy / '\�7 �) Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 0� WAS,,tj, GIS 10 N;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3 03/24/17 DWN COORD SET REV2 03/17/17 DWN COORD SET REV1- 03/02/17 DWN DID SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11 -17-10152 Issue Date 04/12/17 FOUNDATION PLAN - PLUMBING P2000 ISSUE FOR PERMIT D2 ------------------------- ---- ------ ------ -- ---------- - -------------- -- ---------------- --- ---------------- CB. 4"V UP TO THE OUTSIDE. TERMINATE FLAGPOLE VENT 7'-0" ABOVE ROOF CD) ------------ ---- -------- Ag�- (TYP 2) 1"HW DN - 1"HW DN SEE DETAIL (z P5.01 , DE — c6j�- TT 1rCW` I L-2 V- I ET-2 SEE DETAIL,�Z' P5.01 1 0 9 C-7 (�6� 3 2 1. 5�' I 1 "HW UP HAVE INTEGRAL AIR GAP F! 14 TO WATER HEATER- - J""HWC 2"CW J"HW 2"V D 2"CW' �"CW DN ------------------ - J"CW N DN r J"HW 5 ""'�"HW DN 3"RD UP 3"RD UP (197 SF 02-) 4-OW DN 1!2� 9*\l tip N6 SCALE: 3/32" = 1'-0" ",A/ YORD UP (2,837 SF) 3"RD UP (2837 SF) 3"RD DN (2837 SF 02') 4 �4 11�7- Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 '�'o OR 0�, WAS GIS 10 N;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3- 03/24/17 DWN COORD SET REV2 — 03/17/17 DWN COORD SET REV1- 03/02/17 DWN DD SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11 —17-10152 Issue Date 04/12/17 1ST FLOOR PLAN - PLUMBING P2001 ISSUE FOR PERMIT D2 ----------- ---- --------------------- --- ---------------- ------------------------- ---- ------ ------ -- ---------- - -------------- -- ---------------- -- ---------------- CB. OD)— - C6 J�- — - (197 SF 02") 1 0 9 C-7 (�6� 3 2 3�ORD UP ARD UP AD UP SEE DEML,�� P5.01 3"RD UP Y 2ND FLOOR PLAN - PLUMBING SCALE: 3/32" = V-0" Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 �,ODOR 0, WAS GIS 10 IV;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3- 03/24/17 DWN COORD SET REV2 — 03/17/17 DWN COORD SET REV1- 03/02/17 DWN DD SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11 —17-10152 Issue Date 04/12/17 2ND FLOOR PLAN - PLUMBING P2002 ISSUE FOR PERMIT (�) ------------------------- ---- �).8 ------ -- CB. OD)— - c6j�- TT (I (I ROOF SCALE: 3/32" = V-0" �V V Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ MAGIC TOYOTA OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 '�'o OR 0�, WAS,,tj, GIS 10 IV;AL Revisions 04/12/17 DWN ISSUE FOR PERMIT 03/31/17 DWN COORD SET REV3- 03/24/17 DWN COORD SET REV2 — 03/17/17 DWN COORD SET REV1- 03/02/17 DWN DD SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11 —17-10152 Issue Date 04/12/17 ROOF PLAN - PLUMBING P2mR1 ISSUE FOR PERMIT , A " ^111 UNION (TYP) _/ DMHPC'n DDCQQHDC BACKFILOW PREVENTER VALVE ASSEMBLY M BACKFLOW PREVENTER DETAIL P5.01 NOT TO SCALE Q_CD a PRESSURE GAUGE W/COCK y1 " AIR GAP Q INDIRECT DRAIN 0 VVM31 L SPRINKLER DRAIN DETAIL P5.01 NOT TO SCALE — ---------- - SEE PLAN FOR PIPE SIZES RAM P5_01 NOT TO SCALE 0 0 0 0 0 0 4911.61116 4,, 10�10 0 0 0 0 0 0 I �" 1 11 fjmll� TO BE INSULATED la, 0 �01 v CAULKED OR NO -HUB OUTLET (:Z) TYPICAL COMBINED ROOF AND OVERFLOW DRAIN DETAIL P5.01 NOT TO SCALE Z COMBINE OVERFLOW IN VERTICAL PIPE PRESSURE RELIEF VALVE PIPE TO DRAIN NEEDLE VALVE (TYP 2) 11-V _� * - UNION PRESSURE REDUCING VALVE STRAINER BALL VALVE (TYP 2) M 2" & SMALLER WATER PRV STATION DETAIL P5.01 NOT TO SCALE 1-1" VENT MIN. 2 PLASTIC SUPPORT BRACKETS 2" SANITARY TEE TAPPED 1-1'* 4 GATITTIT501-0 2" WASTE MINIMUM THERMOMETER ., EXPANSION TANK PUMP VACUUM RELIEF HWC VALVE CW HW i Y ASME RATED TEMPERATURE T T AND PRESSURE RELIEF VALVE. PIPE DISCHARGE FULL SIZE TO FLOOR DRAIN OR MOP SINK WATER DIELECTRIC UNION (TYP) HEATER SEISMIC STRAP @ 1/3 POINTS OF VERTICAL DIMENSION (TYP 2) R10 INSULATED PAD DRAIN VALVE WITH THREADED HOSE CONNECTI O� 0P-SIV,� FLOOR MOUNTED ELECTRIC WATER HEATER PIPING DIAGRAM P5.01 NOT TO SCALE (WITH RECIRCULATION) FED 'HEONS FLEX RISER TO FIXTURE PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE AT PUBLIC LAVATORIES LOOSE KEY ANGLE STOP VALVE WITH REPLACEABLE CARTRIDGE a 1101M M 0 9 0_0 NF-Al by-0 2 to] CLEAN -OUT PLUG 1-1" TRAP FOR FIXTURE* 4 1"' REQUIRED FOR LAV'S & ELECTRIC DRINKING FOUNTAINS 4 1-1" REQUIRED FOR SINKS 2 (:�:) TYPICAL LAV/SINK/EDF ROUGH -IN DETAIL P5-01 NOT TO SCALE HOTIM PER WSEC C404.3.1 MAX LENGTH FROM HOT WATER MAIN SUPPLY TO TMV ON PUBLIC LAV'S IS 2'FOR 1"HW 2 (TFOR!"HW) FOR OTHER FIXTURES 8 43'FOR "'HW IS ALLOWED. 2 H m coqik n s o n Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ KAAG I C TOYOTA Biwa OFEDMONDS 21300 HIGHWAY 99 EDMONDS, WA 98026 0� WAS �GIS S10 IV;AL Revisions 04/12/17 DWIN ISSUE FOR PERMIT 03/31/17 DWIN COORD SET REV3 03/24/17 DWN COORD SET REV2 03/17/17 DWN COORD SET REV1_ 03/02/17 DWN DID SET No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Project Number 11-17-10152 Issue Date 04/12/17 --------------- DETAIL SHEET - PLUMBING P5mOl