2017-0476 Ingold deck.pdfOV EDAf > St. I Citv of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 14,2017 TO: Mark Ingold Mark@hlgold.org FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2017-0476 Project Address: 1911192 nd AVE W. Scope: New Deck Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicatin where the 'clouded' or otherwise hi2hli2hted chan2es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. Sheet 2: 1. The proposed deck indicates 2x8 P.T. joists. A pressure treated 2x8 joist has a maximum span of 10' when calculating 1OPSF of "dead load" and 60PSF of " live load" per IRC table 301.5. The NE comer of the deck joists are over spanned. You can either upsize the joists to a minimum of 2xlO P. T. or shorten the span to 10' max. Please indicate on the plans which method you will use. 2. IRC 507.2.4 requires the proposed deck to have "lateral load connections" placed with 24" of each end of the deck and not less than 4 per deck. Please see the illustration below for clarification. Please indicate on the plans what type and location of connections will be used. Hold-down or tension device with 1500 # Floor sheathing nailing capacity at 6' o.c. (rnax) to joist with hold-down. Ilk— Deck Joist —/ Sheating Siding Flashing for water tightness Decking Deck joists per page 6 Approved joist hangers Pressure treated 2x ledger wth fasteners per IRC Table R507.2 Holdo,wn device min 7500 capacity FloorjOiSt at 4 locations. evenly distributed along deck & 1 within 2' of each end of the ledger. Holdown devices shall fully engage deck joist per holdown manufacturer (slight olfset allowed). Option # 1 A ruily tFire3deu 3.,8 013meter lag screw predrilled Wmin 3' penetration to (Required for New Construction) top Pl3te.studs. or header. Note: Note: These details are applicable Holdown devices are not required where floorgists are Parallel 'or decks less than 30" high or to deck jois standing decks. Basic UecKs Pa:��-- 4 o; i- 2' min. Floor joists Option # 2 (Existing Construction Only) Page 2 of 2